FQXSPPW0035M : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted.
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Action
Complete the following steps:
- Reseat the identified compute node.
- If the specified sensor is system board 12V, ensure PDB is installed correcly and check the XClarity Controller event log for power-supply-related issues, and resolve those issues.
- If the specified sensor is system board 3.3V or system board 5V, (trained technician only) replace the defective node tray.
- If the problem persists, (trained technician only) replace the PDB or the defective node tray.