Skip to main content

FQXSPMA0012M : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0146

SNMP Trap ID

0

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check the event log of XClarity Controller for any fan- or cooling-related issues.
  2. Make sure that the airflow at the front and rear of the enclosure is not obstructed and that fillers are in place, clean and correctly installed.
  3. Make sure that the room temperature is within operating specifications.
  4. If the problem remains and no other DIMMs have the same indication, replace the DIMM.