FQXSPMA0012M : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check the event log of XClarity Controller for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the enclosure is not obstructed and that fillers are in place, clean and correctly installed.
- Make sure that the room temperature is within operating specifications.
- If the problem remains and no other DIMMs have the same indication, replace the DIMM.