FQXSPMA0008N : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected a Memory uncorrectable error.
Severity
Error
Alert Category
Critical - Memory
Serviceable
Yes
SNMP Trap ID
41
Automatically Notify Support
Yes
User Action
Complete the following steps:
- If the compute node has recently been installed, moved, serviced, or upgraded, verify that the DIMM is properly seated and visually verify that there is no foreign object in any DIMM connector on that memory channel. If either of these conditions is found, correct and retry with the same DIMM. (Note: The event log might contain a recent FQXSFMA0011I event denoting a change is detected in DIMM population which could cause this problem.)
- If no problem is observed on the DIMM connectors or the problem persists, replace the DIMM identified by LightPath and/or event log entry.
- If the problem recurs on the same DIMM connector, replace the other DIMMs on the same memory channel.
- Check the Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error.
- If the problem recurs on the same DIMM connector, inspect connector for damage. If any damage is found or the problem persists, collect the Service Data log.
- Contact Lenovo Support.
Give documentation feedback