FQXSPPW0063M : Sensor [SensorElementName] has transitioned to critical from a less severe state.
Sensor [SensorElementName] has transitioned to critical from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Action
Complete the following steps:
Perform virtual system reseat or A/C power cycle.
If the error persists, remove A/C power and any recently installed components.
If the system successfully powers on, complete the following steps:
Check the Server Proven website (http://www.lenovo.com/us/en/serverproven/index.shtml) to make sure that recently installed components are compatible with the system.
Inspect the previously installed components for physical damage and fix it.
If the system does not successfully power on or if this is not the first occurrence of this problem, go to step 4.
If the system has stand-by power, collect Service Data logs.
Contact Lenovo Support.