80070219-0701xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe state. (SysBrd Fault)

Sensor [SensorElementName] has transitioned to critical from a less severe state. (SysBrd Fault)

This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

May also be shown as 800702190701xxxx or 0x800702190701xxxx

Severity

Error

Alert Category

Critical - Other

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0522

SNMP Trap ID

50

Automatically Notify Support

No

User Response

  1. Check for an error LED on the system board.
  2. Check the system-event log.
  3. Check for the system firmware version and update to the latest version. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  4. Unplug and restore AC power cord, then, perform step 1 and 2 again.
  5. If problems still occurred, (trained technician only) replace the system board.