806f000f-22010bxx : Firmware BIOS (ROM) corruption was detected on system [ComputerSystemElementName] during POST. (ABR Status)
Firmware BIOS (ROM) corruption was detected on system [ComputerSystemElementName] during POST. (ABR Status)
Firmware BIOS (ROM) corruption was detected on the system during POST.
May also be shown as 806f000f22010bxx or 0x806f000f22010bxx
Severity
Info
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
40
Automatically Notify Support
No
User Response
- Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
- Recover the server firmware from the backup page: a.Restart the server. b.At the prompt, press F3 to recover the firmware.
- Update the server firmware to the latest level (see Updating the firmware). Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
- Remove components one at a time, restarting the server each time, to see if the problem goes away.
- If the problem remains, (trained service technician) replace the system board.
Give documentation feedback