80070608-0a01xxxx : Sensor [SensorElementName] has transitioned to non-recoverable. (PS1 12V OC Fault)

Sensor [SensorElementName] has transitioned to non-recoverable. (PS1 12V OC Fault)

This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

May also be shown as 800706080a01xxxx or 0x800706080a01xxxx

Severity

Error

Alert Category

Critical - Power

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0530

SNMP Trap ID

4

Automatically Notify Support

No

User Response

If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is solved:

  1. Use the Lenovo Power Configurator utility to determine current system power consumption. For more information and to download the utility, go to https://www.ibm.com/support/entry/myportal/docdisplay?lndocid=LNVO-PWRCONF.
  2. Follow actions in "Power Problems and Solving Power Problems".
If the specified sensor is PS n 12V OV Fault, complete the following steps until the problem is solved:
  1. Check power supply n LED.
  2. Remove the failing power supply.
  3. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete the following steps until the problem is solved:
  1. Check power supply n LED.
  2. Remove the failing power supply.
  3. Follow actions in "Power Problems and Solving Power Problems".
  4. (Trained technician only) Replace the system board. (n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete the following steps until the problem is solved:
  1. Check power supply n LED.
  2. Replace power supply n. (n = power supply number)
PS1 12V OV Fault : PS1 12V UV Fault : PS1 12Vaux Fault :