806f060d-041axxxx : Array [ComputerSystemElementName] has failed. (Drive 26)
Array [ComputerSystemElementName] has failed. (Drive 26)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d041axxxx or 0x806f060d041axxxx
Severity
Error
Alert Category
Critical - Hard Disk drive
Serviceable
Yes
SNMP Trap ID
5
Automatically Notify Support
Yes
User Response
- Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
- Make sure that the SAS cable is connected correctly.
- Replace the SAS cable.
- Replace the RAID adapter.
- Replace the hard disk drive that is indicated by a lit status LED.
Give documentation feedback