80070608-0a02xxxx : Sensor [SensorElementName] has transitioned to non-recoverable. (PS2 12V OC Fault)
Sensor [SensorElementName] has transitioned to non-recoverable. (PS2 12V OC Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.
May also be shown as 800706080a02xxxx or 0x800706080a02xxxx
Severity
Error
Alert Category
Critical - Power
Serviceable
Yes
SNMP Trap ID
4
Automatically Notify Support
No
User Response
If the specified sensor is PS n 12V OC Fault, complete the following steps until the problem is solved:
- Use the Lenovo Power Configurator utility to determine current system power consumption. For more information and to download the utility, go to https://www.ibm.com/support/entry/myportal/docdisplay?lndocid=LNVO-PWRCONF.
- Follow actions in "Power Problems and Solving Power Problems".
- Check power supply n LED.
- Remove the failing power supply.
- (Trained technician only) Replace the system board. (n = power supply number)
- Check power supply n LED.
- Remove the failing power supply.
- Follow actions in "Power Problems and Solving Power Problems".
- (Trained technician only) Replace the system board. (n = power supply number)
- Check power supply n LED.
- Replace power supply n. (n = power supply number)