The following illustrations show the light-emitting diodes (LEDs) on the Firmware and Root of Trust Security Module (firmware and RoT security module).

Figure 1. LEDs on the firmware and RoT security module

1 AP0 LED (Green)2 AP1 LED (Green)3 Fatal Error LED (Amber)
Table 1. LEDs description
ScenarioAP0 LEDAP1 LEDFatal Error LEDFPGA heartbeat LEDnoteXCC heartbeat LEDnoteActions
RoT security module fatal firmware failureOffOffOnN/AN/AReplace the firmware and RoT security module.
BlinkN/AOnN/AN/AReplace the firmware and RoT security module.
BlinkN/AOnOnN/AReplace the firmware and RoT security module.
No system power (FPGA heartbeat LED off)OffOffOffOffOffIf the AC power is on, but the system board assembly does not have power, then:
  1. Check the power supply unit (PSU) or power backplane. If the PSU or power backplane has any error, replace it.

  2. If the PSU or power backplane is good, replace the system board.

XCC firmware recoverable errorBlinkN/AOffN/AN/AInformation only. No action is required.
XCC firmware is recovered from errorOnN/AOffN/AN/AInformation only. No action is required.
UEFI firmware authentication failureN/ABlinkOffN/AN/AInformation only. No action is required.
UEFI firmware is recovered from authentication failureN/AOnOffN/AN/AInformation only. No action is required.
System is OK (FPGA heartbeat LED is On)OnOnOffOnOnInformation only. No action is required.