Skip to main content

4 x 2.5'' SAS/SATA backplane

Use this section to understand the SAS/SATA backplane cable routing for server model with four 2.5-inch front drives.

To connect signal cables for 4 x 2.5-inch SAS/SATA configuration, refer to the following cable routing scenarios depending on your server configuration:

Cable routing for onboard configuration

The following figure illustrates the cable routing for the onboard configuration of 4 x 2.5-inch front SAS/SATA drive bays.Connections between connectors: 11, 22, 33, ... nn.

Figure 1. Cable routing for onboard configuration of 4 x 2.5-inch front SAS/SATA drive bays
Cable routing for onboard configuration of 4 x 2.5-inch front AnyBay drive bays

Table 1. Mapping between backplane connectors and system board assembly connectors for onboard configuration
FromTo
1 SAS on the front backplane1 PCIe connector 8 on the system board assembly

Cable routing with an SFF HBA/RAID adapter

The following figure shows the mapping relationship between backplane connectors and system board assembly/adapter connectors when an 8i SFF HBA/RAID adapter (Gen 3 or Gen 4) is installed.

Figure 2. Cable routing for 4 x 2.5-inch front SAS/SATA drive bays with an 8i SFF RAID adapter (Gen 3/ Gen 4)
Note

Gen 3 and Gen 4 SFF RAID/HBA adapters are slightly different in their connectors, but the connection method is similar. The following illustration takes Gen 4 SFF RAID/HBA adapters as an example.


Cable routing for 4 x 2.5-inch front AnyBay drive bays with an 8i SFF RAID adapter

Table 2. Mapping between backplane connectors and system board assembly/adapter connectors when an 8i SFF HBA/RAID adapter is installed
FromTo
1 SAS on the front backplane1 C0 on the SFF HBA/RAID adapter