Skip to main content

Server model with six 2.5-inch SAS/SATA drives and four 2.5-inch NVMe drives

Use this section to understand the connectors on the backplane and the internal cable routing for server model with six 2.5-inch SAS/SATA drives and four 2.5-inch NVMe drives.

Figure 1. Connectors on the backplane for six 2.5-inch SAS/SATA drives and four 2.5-inch NVMe drives
Connectors on the backplane for six 2.5-inch SAS/SATA drives and four 2.5-inch NVMe drives

1 SAS 2 connector2 SAS 1 connector3 Power connector4 SAS 0 connector
5 NVMe 1 connector6 NVMe 0 connector7 NVMe 3 connector8 NVMe 2 connector
Note
  • NVMe drives are only supported in drive bays 6–9.

For power cable connection, see Power/Sideband cable routing.

Six 2.5-inch SATA drives and four 2.5-inch NVMe drives

Note
When the SAS/SATA backplanes are connected to PCIe connectors on the system board, only SATA drives are supported. No SAS drives are supported.
Figure 2. Cable routing for server model with six 2.5-inch SATA drives and four 2.5-inch NVMe drives
Cable routing for server model with six 2.5-inch SATA drives, four 2.5-inch NVMe drives

CableFromTo
1 NVMe signal cable for front backplaneNVMe 0 and NVMe 1 connectors on the front backplanePCIe connector 1 on the system board
2 NVMe signal cable for front backplaneNVMe 2 and NVMe 3 connectors on the front backplanePCIe connector 2 on the system board
3 SAS signal cable for front backplaneSAS 2 connector on the front backplanePCIe connector 7 on the system board
4 SAS signal cable for front backplaneSAS 0 and SAS 1 connectors on the front backplanePCIe connector 6 on the system board

Six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives and one 16i RAID/HBA adapter

Figure 3. Cable routing for server model with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives and one 16i RAID/HBA adapter
Cable routing for server model with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives and one 16i RAID/HBA adapter

Note
  • RAID/HBA adapters can be installed in PCIe slot 1 or internal riser assembly.

  • When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:

    ThinkSystem SR635 Front 6x2.5" SAS/SATA + 4x2.5" AnyBay X40 RAID Cable Kit

CableFromTo
1 NVMe signal cable for front backplaneNVMe 0 and NVMe 1 connectors on the front backplanePCIe connector 1 on the system board
2 NVMe signal cable for front backplaneNVMe 2 and NVMe 3 connectors on the front backplanePCIe connector 2 on the system board
3 SAS signal cable for front backplaneSAS 0 and SAS 1 connectors on the front backplaneThe RAID/HBA adapter
  • Gen 3: C0C1

  • Gen 4: C0

4 SAS signal cable for front backplaneSAS 2 connector on the front backplaneThe RAID/HBA adapter
  • Gen 3: C2

  • Gen 4: C1

Six 2.5-inch SATA drives, four 2.5-inch NVMe drives and rear SAS/SATA drive assembly

Note
  • When the SAS/SATA backplanes are connected to PCIe connectors on the system board, only SATA drives are supported. No SAS drives are supported.

  • The cable routing illustration is based on the scenario that the rear hot-swap drive cage is installed. Depending on the model, the rear hot-swap drive cage might not be available on your server.

Figure 4. Cable routing for server model with six 2.5-inch SATA drives, four 2.5-inch NVMe drives and rear SAS/SATA drive assembly
Cable routing for server model with six 2.5-inch SATA drives, four 2.5-inch NVMe drives and rear SAS/SATA drive assembly

Note
M.2 drive is not supported for this configuration.
CableFromTo
1 NVMe signal cable for front backplaneNVMe 0 and NVMe 1 connectors on the front backplanePCIe connector 1 on the system board
2 NVMe signal cable for front backplaneNVMe 2 and NVMe 3 connectors on the front backplanePCIe connector 2 on the system board
3 SAS signal cable for front backplaneSAS 0 and SAS1 connectors on the front backplanePCIe connector 6 on the system board
4 SAS signal cable for front backplaneSAS 2 connector on the front backplanePCIe connector 7 on the system board
5 SAS signal cable for rear backplaneSAS connector on the rear backplanePCIe connector 8 on the system board

Six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, rear SAS/SATA drive assembly and one 16i RAID/HBA adapter

Note
The cable routing illustration is based on the scenario that the rear hot-swap drive cage is installed. Depending on the model, the rear hot-swap drive cage might not be available on your server.
Figure 5. Cable routing for server model with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, rear SAS/SATA drive assembly and one 16i RAID/HBA adapter
Cable routing for server model with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, rear SAS/SATA drive assembly and one 16i RAID/HBA adapter

Note
  • RAID/HBA adapters can be installed in PCIe slot 1 or internal riser assembly.

  • When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:

    For cable 3: ThinkSystem SR635 Front 6x2.5" SAS/SATA + 4x2.5" AnyBay X40 RAID Cable Kit

    For cable 4 and 5: ThinkSystem SR635 2.5” SAS/SATA 2-Bay Rear Backplane X40 RAID Cable Kit

CableFromTo
1 NVMe signal cable for front backplaneNVMe 0 and NVMe 1 connectors on the front backplanePCIe connector 1 on the system board
2 NVMe signal cable for front backplaneNVMe 2 and NVMe 3 connectors on the front backplanePCIe connector 2 on the system board
3 SAS signal cable for front backplaneSAS 0 and SAS 1 connectors on the front backplaneThe RAID/HBA adapter
  • Gen 3: C0C1

  • Gen 4: C0

4 SAS signal cable for front backplaneSAS 2 connector on the front backplaneThe RAID/HBA adapter
  • Gen 3: C2

  • Gen 4: C1

5 SAS signal cable for rear backplaneSAS connector on the rear backplaneThe RAID/HBA adapter
  • Gen 3: C3

  • Gen 4: C1

Six 2.5-inch SATA drives, four 2.5-inch NVMe drives and rear NVMe drive assembly

Note
  • When the SAS/SATA backplanes are connected to PCIe connectors on the system board, only SATA drives are supported. No SAS drives are supported.

  • The cable routing illustration is based on the scenario that the rear hot-swap drive cage is installed. Depending on the model, the rear hot-swap drive cage might not be available on your server.

Figure 6. Cable routing for server model with six 2.5-inch SATA drives, four 2.5-inch NVMe drives and rear NVMe drive assembly
Cable routing for server model with six 2.5-inch SATA drives, four 2.5-inch NVMe drives and rear NVMe drive assembly

CableFromTo
1 NVMe signal cable for front backplaneNVMe 0 and NVMe 1 connectors on the front backplanePCIe connector 1 on the system board
2 NVMe signal cable for front backplaneNVMe 2 and NVMe 3 connectors on the front backplanePCIe connector 2 on the system board
3 SAS signal cable for front backplaneSAS 0 and SAS1 connectors on the front backplanePCIe connector 6 on the system board
4 SAS signal cable for front backplaneSAS 2 connector on the front backplanePCIe connector 7 on the system board
5 NVMe signal cable for rear backplaneNVMe connectors on the rear backplanePCIe connector 3 on the system board

Six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, rear NVMe drive assembly and one 16i RAID/HBA adapter

Note
The cable routing illustration is based on the scenario that the rear hot-swap drive cage is installed. Depending on the model, the rear hot-swap drive cage might not be available on your server.
Figure 7. Cable routing for server model with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, rear NVMe drive assembly and one 16i RAID/HBA adapter
Cable routing for server model with six 2.5-inch SAS/SATA drives, four 2.5-inch NVMe drives, rear NVMe drive assembly and one 16i RAID/HBA adapter

Note
  • RAID/HBA adapters can be installed in PCIe slot 1 or internal riser assembly.

  • When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:

    ThinkSystem SR635 Front 6x2.5" SAS/SATA + 4x2.5" AnyBay X40 RAID Cable Kit

CableFromTo
1 NVMe signal cable for front backplaneNVMe 2 and NVMe 3 connectors on the front backplanePCIe connector 2 on the system board
2 NVMe signal cable for front backplaneNVMe 0 and NVMe 1 connectors on the front backplanePCIe connector 1 on the system board
3 NVMe signal cable for rear backplaneNVMe connectors on the rear backplanePCIe connector 3 on the system board
4 SAS signal cable for front backplaneSAS 2 connector on the front backplaneThe RAID/HBA adapter
  • Gen 3: C2

  • Gen 4: C1

5 SAS signal cable for front backplaneSAS 0 and SAS 1 connectors on the front backplaneThe RAID/HBA adapter
  • Gen 3: C0C1

  • Gen 4: C0