Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.
Procedure
Touch the static-protective package that contains the diagnostics panel assembly to any unpainted surface on the outside of the server. And then, take the assembly out of the package and place it on a static-protective surface.
If there is a filler installed on the front chassis, remove it as shown.
Figure 1. Filler removal
Insert the integrated diagnostics panel assembly into its assembly. Ensure that the panel is fully seated into its assembly.
Figure 2. Integrated diagnostics panel assembly installation into its assembly
Slide the diagnostics panel assembly into the front chassis as shown. And ensure that it is seated in place.