Install the external diagnostics cable (4 x 3.5'' chassis)

Use this information to install the external diagnostics cable.

In the 4 x 3.5'' chassis configuration, the external diagnostics cable is an optional part. You can choose either install or remove the cable according to your actual needs. Refer to the location of external diagnostics cable from the front view as below:
Figure 1. A front view with the cable installed

1 The external diagnostics cable connector

Figure 2. A front view with a filler installed

1 A filler for external diagnostics cable connector

Note
Before installing the cable, remove the filler first; after removing the cable, install the filler afterwards.

About this task

The following illustrates how to remove the external diagnostics cable from the chassis.

Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.

  • Power off the server and peripheral devices and disconnect the power cords and all external cables. See Power off the server.

  • Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-sensitive components in their static-protective packages until installation, and handling these devices with an electrostatic-discharge wrist strap or other grounding system.

Procedure

  1. Touch the static-protective package that contains the external diagnostics cable to any unpainted surface on the outside of the server. Then, take the external diagnostics LCD cable out of the package and place it on a static-protective surface.
  2. Install the external diagnostics cable.
    Figure 3. Installation of the external diagnostics cable
    Removal of the front I/O assembly
    Note

    The front and back sides of the connector to external diagnostics slot are different, and it is required to plug in with the front side.

    When plugging in, face the front side upward and slide the connector into the chassis. Refer to the illustration above.

After you finish

  1. Connect the external diagnostics cable to the processor board. See Internal cable routing.

  2. Complete the parts replacement. See Complete the parts replacement.