Skip to main content

Front (16 x 2.5" SAS/SATA + 8 x 2.5" AnyBay) + Middle 8 x 2.5" SAS/SATA

This topic provides cable routing information for the front (16 x 2.5" SAS/SATA + 8 x 2.5" AnyBay) + middle 8 x 2.5" SAS/SATA configuration.

Cable routing to SFF 16i adapters

Note
The location of the adapter and cable connectors on the adapter may differ from those shown in the illustration. For details, see the table below.
Figure 1. Cable routing from front backplanes to SFF 16i adapters

FromToCable length
1 BP1: SAS1 16i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

900 mm
2 BP2: SAS2
  • Gen 4: C1

  • Gen 3: C2C3

900 mm
3 BP3: SAS3 16i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

900 mm
Figure 2. Cable routing from middle backplanes to SFF 16i adapter

FromToCable length
1a BP10: SAS1 16i adapter:
  • Gen 4: C1

  • Gen 3: C2C3

400/260 mm
1b BP11: SAS

NVMe cable routing to BP3

Figure 3. Cable routing when two processors are installed

Figure 4. Cable routing when one processor is installed

2P: two processors; 1P: one processor
From (BP3)To (processor board)Cable length
2P1P
1 NVMe 0-11 PCIe 61 PCIe 4350 mm
2 NVMe 2-32 PCIe 52 PCIe 3350 mm
3 NVMe 4-53 PCIe 43 PCIe 2350 mm
4 NVMe 6-74 PCIe 34 PCIe 1350 mm