Skip to main content

Front (16 x 2.5" SAS/SATA + 8 x 2.5" AnyBay) + Rear 4/8 x 2.5" SAS/SATA

This topic provides cable routing information for the front (16 x 2.5" SAS/SATA + 8 x 2.5" AnyBay) + rear 4 x 2.5"/8 x 2.5" SAS/SATA configuration.

The configuration numbers in the table below are for descriptive purposes only.
BP config.Storage controllerConfig. No.
Front (16 x 2.5" SAS/SATA + 8 x 2.5" AnyBay) + rear 4 x 2.5" SAS/SATA (BP1 + BP2 + BP3 + BP9)SFF 16i + 2 x SFF 8i1
2 x SFF 16i2
CFF 16i + 2 x SFF 8i3
CFF 16i + SFF 16i4
Front (16 x 2.5" SAS/SATA + 8 x 2.5" AnyBay) + rear 8 x 2.5" SAS/SATA (BP1 + BP2 + BP3 + BP9)2 x SFF 16i5

NVMe cable routing to BP3 (config. 1/2/3/4/5)

Figure 1. Cable routing when two processors are installed

Figure 2. Cable routing when one processor is installed

2P: two processors; 1P: one processor
From (BP3)To (processor board)Cable length
2P1P
1 NVMe 0-11 PCIe 61 PCIe 4350 mm
2 NVMe 2-32 PCIe 52 PCIe 3350 mm
3 NVMe 4-53 PCIe 43 PCIe 2350 mm
4 NVMe 6-74 PCIe 34 PCIe 1350 mm

Cable routing to SFF 8i/16i adapter (config. 1/2)

Note
The location of the adapter and cable connectors on the adapter may differ from those shown in the illustration. For details, see the table below.
Figure 3. Cable routing to SFF 8i/16i adapter (config. 1/2)

FromToCable length
Config. 1Config. 2
1 BP1: SAS1 16i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

1 16i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

900 mm
2 BP2: SAS2
  • Gen 4: C1

  • Gen 3: C2C3

2
  • Gen 4: C1

  • Gen 3: C2C3

900 mm
3 BP3: SAS3 8i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

3 16i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

900 mm
4 BP9: SAS4 8i adapter: C04
  • Gen 4: C1

  • Gen 3: C2

450 mm

Cable routing to SFF 8i/16i adapter (config. 3/4)

Note
The location of the adapter and cable connectors on the adapter may differ from those shown in the illustration. For details, see the table below.
Figure 4. Cable routing to SFF 8i/16i adapter (config. 3/4)

FromToCable length
Config. 3Config. 4
1 BP3: SAS1 8i adapter:
  • C0

1 16i adapter:
  • C0

900 mm
2 BP9: SAS2 8i adapter:
  • C0

2
  • C1

450 mm

Cable routing to CFF 16i adapter (config. 3/4)

Figure 5. Cable routing when two processors are installed

Figure 6. Cable routing when one processor is installed

2P: two processors; 1P: one processor; PB: processor board
From (CFF 16i adapter)ToCable length
2P1P
1 POWER

1 PB: RAID PWR

1a PB: RAID PWR
  • 2P: 210 mm

  • 1P: 300/800 mm

1b PB: PWR 14
2a C02 BP1: SAS2 BP1: SAS
  • 140/140 mm

2b C1
3a C23 BP2: SAS3 BP2: SAS
  • 140/140 mm

3b C3
4 MB (CFF INPUT)4 PB: PCIe 74 PB: PCIe 10
  • 2P: 450 mm

  • 1P: 900 mm

Cable routing to SFF 16i adapters (config. 5)

Note
The location of the adapter and cable connectors on the adapter may differ from those shown in the illustration. For details, see the table below.
Figure 7. Cable routing to SFF 16i adapters

FromToCable length
1 BP1: SAS1 16i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

900 mm
2 BP2: SAS2
  • Gen 4: C1

  • Gen 3: C2C3

900 mm
3 BP3: SAS3 16i adapter:
  • Gen 4: C0

  • Gen 3: C0C1

900 mm
4a BP9: SAS 14
  • Gen 4: C1

  • Gen 3: C2C3

260/400 mm
4b BP9: SAS 0