80070101-2c02ffff : Sensor Mezz Exp 2 temp has transitioned from normal to non-critical state.
Sensor Mezz Exp 2 temp has transitioned from normal to non-critical state.
The temperature of the I/O expansion adapter in I/O expansion connector 2 has exceeded its specified threshold.
May also be shown as 800701012c02ffff or 0x800701012c02ffff
Severity
Warning
Alert Category
Warning - Temperature
Serviceable
Yes
SNMP Trap ID
12
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.