80070301-3103ffff : Sensor PCIE 3 Overtemp has transitioned to non-recoverable from a less severe state.
Sensor PCIE 3 Overtemp has transitioned to non-recoverable from a less severe state.
Sensor PCIE 3 Overtemp has transitioned to critical from a less severe state. The compute node has attempted a soft shutdown.
May also be shown as 800703013103ffff or 0x800703013103ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed. 3. Make sure that the room temperature is within operating specifications. 4. If there are no other thermal issues, replace the PCIe Card.
Give feedback