80070301-3702ffff : Sensor PEN Inlet Over T has transitioned to non-recoverable from a less severe state.
Sensor PEN Inlet Over T has transitioned to non-recoverable from a less severe state.
The PCIe Expansion Node Inlet temperature has exceeded its specified threshold. The compute node has attempted a soft shutdown.
May also be shown as 800703013702ffff or 0x800703013702ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
- Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.