80070301-3702ffff : Sensor PEN Inlet Over T has transitioned to non-recoverable from a less severe state.

Sensor PEN Inlet Over T has transitioned to non-recoverable from a less severe state.

The PCIe Expansion Node Inlet temperature has exceeded its specified threshold. The compute node has attempted a soft shutdown.

May also be shown as 800703013702ffff or 0x800703013702ffff

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0524

SNMP Trap ID

0

Automatically Notify Support

No

User Response

  1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  3. Make sure that the room temperature is within operating specifications.