806f090c-200a010a : memory device 10 in Group 1 on Subsystem System Memory Throttled
memory device 10 in Group 1 on Subsystem System Memory Throttled
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c200a010a or 0x806f090c200a010a
Severity
Warning
Alert Category
System - Other
Serviceable
Yes
SNMP Trap ID
22
Automatically Notify Support
No
User Response
Complete the following steps:
- Check the CMM or FSM event log for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Make sure that the DIMM baffles are in place.
- If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
Give documentation feedback