80070217-2c01ffff : Sensor Mezz Exp 1 Fault has transitioned to critical from a less severe state.
Sensor Mezz Exp 1 Fault has transitioned to critical from a less severe state.
A problem has been detected in the I/O expansion adapter in I/O expansion connector 1. The adapter is unable to initialize.
May also be shown as 800702172c01ffff or 0x800702172c01ffff
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
No
User Response
Complete the following steps:
- Remove any recently installed components from the PCI expansion unit.
- Try to power on the chassis.
- If the chassis successfully powers on, complete the following steps:
- Check the ServerProven website to make sure that recently installed components are compatible with the chassis.
- Inspect the previously installed components for physical damage.
- If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the PCI expansion unit.
- If the chassis successfully powers on, complete the following steps: