80070601-2c01ffff : Sensor Mezz Exp 1 temp has transitioned to non-recoverable.
Sensor Mezz Exp 1 temp has transitioned to non-recoverable.
The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified threshold. The compute node has attempted a soft shutdown.
May also be shown as 800706012c01ffff or 0x800706012c01ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- If there are no other thermal issues, replace the I/O expansion adapter.