806f0a0c-200c010c : An Over-Temperature Condition has been detected on the memory device 12 in Group 1 on Subsystem System Memory.
An Over-Temperature Condition has been detected on the memory device 12 in Group 1 on Subsystem System Memory.
An overtemperature condition has been detected in the DIMM in DIMM connector 12.
May also be shown as 806f0a0c200c010c or 0x806f0a0c200c010c
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Make sure that the DIMM baffles are in place.
- If the problem remains and no other DIMMs have the same indication, replace the DIMM.