Skip to main content

Replacing the rear adapter retention bracket

This procedure applies only to the 5U server model with hot-swap power supplies.

To install the rear adapter-retention bracket on the 5U server model with hot-swap power supplies, complete the following steps.

  1. Read the safety information in Safety and Installation guidelines.
  2. Position the rear adapter-retention bracket so that the hole in one of the hinge points is aligned with the hinge pin on the chassis; then, place the hinge pin through the hole on the chassis.
  3. Rotate the rear adapter-retention bracket into place so that the hole in the opposite hinge point snaps into place over the hinge pin on the chassis.
    Figure 1. Rear adapter-retention bracket installation for 5U server model with hot-swap power supplies
    Rear adapter-retention bracket installation for 5U server model with hot-swap power supplies
  4. Install the adapters.
  5. Stand the server back up in its vertical position.
  6. Install and lock the side cover (see Replacing the side cover).
  7. Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.