Replacing the non-hot-swap power supply
This procedure applies only to 4U server models with non-hot-swap power supplies.
Statement 8
![](d3mm9elt.jpg)
![](d3mm9elt.jpg)
CAUTION
Never remove the cover on a power supply or any part that has the following label attached.
![](d3mm9902.jpg)
![](d3mm9902.jpg)
Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a with one of these parts, contact a service technician.
To install a non-hot-swap power supply on 4U server models with non-hot-swap power supplies, complete the following steps.
- Read the safety information in Safety and Installation guidelines.
- Position the power supply in the chassis so that the screw holes in the power supply are aligned with the corresponding holes in the rear of the chassis.Figure 1. Non-hot-swap power supply installation for 4U server model with non-hot-swap power supplies (1)NoteMake sure the top and the bottom of the power supply align with the upper and lower tabs on the opening.Figure 2. Non-hot-swap power supply installation for 4U server model with non-hot-swap power supplies (2)
- Install the six screws to secure the power supply to the chassis.
- Install the air baffle (see Replacing the air baffle).
- Install the side cover (see Replacing the side cover).
- Stand the server back up in its vertical position.
- Install the bezel (see Replacing the bezel).
- Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.