Replacing the non-hot-swap power supply
This procedure applies only to 4U server models with non-hot-swap power supplies.
Statement 8
CAUTION
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a with one of these parts, contact a service technician.
To install a non-hot-swap power supply on 4U server models with non-hot-swap power supplies, complete the following steps.
- Read the safety information in Safety and Installation guidelines.
- Position the power supply in the chassis so that the screw holes in the power supply are aligned with the corresponding holes in the rear of the chassis.Figure 1. Non-hot-swap power supply installation for 4U server model with non-hot-swap power supplies (1)NoteMake sure the top and the bottom of the power supply align with the upper and lower tabs on the opening.Figure 2. Non-hot-swap power supply installation for 4U server model with non-hot-swap power supplies (2)
- Install the six screws to secure the power supply to the chassis.
- Install the air baffle (see Replacing the air baffle).
- Install the side cover (see Replacing the side cover).
- Stand the server back up in its vertical position.
- Install the bezel (see Replacing the bezel).
- Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.
Give documentation feedback