6 x 2.5'' SAS/SATA + 4 x 2.5'' AnyBay
See this section to understand the cable routing of 6 front SAS/SATA drives and 4 front AnyBay drives with the 6 x 2.5'' SAS/SATA + 4 x 2.5'' AnyBay backplane installed.
To connect cables for a 7mm drive backplane, refer to 7mm drive backplane.
To connect power cables for a backplane for standard 2.5-inch or 3.5-inch drives, refer to Cable routing for backplane power.
To connect cables for M.2 drives, refer to M.2 drive backplane.
Cable routing for onboard configuration
The following tables show the mapping relationship between backplane connectors and processor board connectors for onboard configuration.
The following figure illustrates the cable routing for the configuration of 6 front SAS/SATA drives and 4 front AnyBay drives bays. Connections between connectors: 1 ↔ 1, 2 ↔ 2, 3 ↔ 3, ... n ↔ n.
Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0 | 1 SATA 0 |
2 SAS 1, SAS 2 | 2 SATA 1, SATA 2 | |
Front BP (NVMe) | 3 NVMe 2–3, 0–1 | 3 PCIe 1, 2 |
Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0 | 1 SATA 0 |
2 SAS 1 | 2 SATA 1 | |
Front BP (NVMe) | 3 NVMe 2–3, 0–1 | 3 PCIe 1, PCIe 2 |
Cable routing with an SFF HBA/RAID adapter
The following tables show the mapping relationship between backplane connectors and a 16i SFF HBA/RAID adapter (Gen 3 or Gen 4).
Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0, SAS 1 | 1 C0 |
Front BP (NVMe) | 2 NVMe 2–3, 0–1 | 2 PCIe 1, 2 |
Front BP (SAS) | 3 SAS 2 | 3 C1 |
Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0, SAS 1 | 1 C0 |
Front BP (NVMe) | 2 NVMe 2–3, 0–1 | 2 PCIe 1, 2 |
Front and Rear BP (SAS) | 3 SAS 2 (front), SAS (rear) | 3 C1 |
Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0, SAS 1 | 1 C0, C1 |
Front BP (NVMe) | 2 NVMe 2–3, 0–1 | 2 PCIe 1, 2 |
Front BP (SAS) | 3 SAS 2 | 3 C2 |
Backplane | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0, SAS 1 | 1 C0, C1 |
Front BP (NVMe) | 2 NVMe 2–3, 0–1 | 2 PCIe 1, 2 |
Front BP (SAS) | 3 SAS 2 | 3 C2 |
Front and Rear BP (SAS) | 4 SAS (rear) | 4 C3 |
Cable routing with a CFF RAID adapter
The following tables show the mapping relationship between backplane connectors and a 16i CFF RAID adapter (Gen 3 or Gen 4).
Backplane/adapter | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0 | 1 C0 |
2 SAS 1 | 2 C1 | |
Front BP (NVMe) | 3 NVMe 2–3, 0–1 | 3 PCIe 1, 2 |
Front BP (SAS) | 4 SAS 2 | 4 C2 |
CFF RAID adapter | 5 MB input | 5 PCIe 3 |
Backplane/adapter | From | To |
---|---|---|
Front BP (SAS) | 1 SAS 0 | 1 C0 |
2 SAS 1 | 2 C1 | |
Front BP (NVMe) | 3 NVMe 2–3, 0–1 | 3 PCIe 1, 2 |
Front BP (SAS) | 4 SAS 2 | 4 C2 |
CFF RAID adapter | 5 MB input | 5 PCIe 3 |
6 C3 | 6 SAS (rear) |