Server model with 24 x 2.5-inch front drive bays (16 SAS/SATA + 8 NVMe)
This section provides cable routing information for the server model with two 8 x 2.5-inch SAS/SATA front backplanes and one 8 x 2.5-inch NVMe front backplane. The NVMe backplane provides eight NVMe drive bays (bays 0–7).
Configuration 1: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), onboard connections
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 and SAS 1 connectors on the SAS/SATA backplane 1 | PCIe connector 6 on the system board |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | PCIe connector 7 on the system board |
5 SAS signal cable | SAS 1 connector on the SAS/SATA backplane 2 | PCIe connector 8 on the system board |
Configuration 2: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one 16i RAID/HBA adapter
When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:
ThinkSystem SR655 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
3 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 1 | The RAID/HBA adapter
|
SAS 1 connector on the SAS/SATA backplane 1 | The RAID/HBA adapter
| |
5 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | The RAID/HBA adapter
|
SAS 1 connector on the SAS/SATA backplane 2 | The RAID/HBA adapter
|
Configuration 3: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), two 8i RAID/HBA adapters
When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:
ThinkSystem SR655 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 1 | The RAID/HBA adapter on the internal riser card
|
SAS 1 connector on the SAS/SATA backplane 1 | The RAID/HBA adapter on the internal riser card
| |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | The RAID/HBA adapter on riser card 1
|
SAS 1 connector on the SAS/SATA backplane 2 | The RAID/HBA adapter on riser card 1
|
Configuration 4: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one rear drive cage (SAS/SATA), one 24i RAID adapter
This configuration supports one rear 2.5-inch drive cage with a 4 x 2.5-inch SAS/SATA drive backplane.
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 1 | Connector C0 on the RAID adapter |
SAS 1 connector on the SAS/SATA backplane 1 | Connector C1 on the RAID adapter | |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | Connector C2 on the RAID adapter |
SAS 1 connector on the SAS/SATA backplane 2 | Connector C3 on the RAID adapter | |
5 SAS signal cable | SAS connector on the rear backplane | Connector C4 on the RAID adapter |
Configuration 5: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one rear drive cage (SAS/SATA), two RAID/HBA adapters (8i+16i)
This configuration supports one rear 2.5-inch drive cage with a 4 x 2.5-inch SAS/SATA drive backplane.
When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:
For cable 3 and 4: ThinkSystem SR655 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
For cable 5: ThinkSystem SR655 2.5" & 3.5" SAS/SATA 4-Bay Rear Backplane X40 RAID Cable Kit
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 1 | The 16i RAID/HBA adapter
|
SAS 1 connector on the SAS/SATA backplane 1 | The 16i RAID/HBA adapter
| |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | The 16i RAID/HBA adapter
|
SAS 1 connector on the SAS/SATA backplane 2 | The 16i RAID/HBA adapter
| |
5 SAS signal cable | SAS connector on the rear backplane | The 8i RAID/HBA adapter
|
Configuration 6: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one rear drive cage (SAS/SATA), three 8i RAID/HBA adapters
This configuration supports one rear 2.5-inch drive cage with a 4 x 2.5-inch SAS/SATA drive backplane.
When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:
For cable 3 and 4: ThinkSystem SR655 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
For cable 5: ThinkSystem SR655 2.5" & 3.5" SAS/SATA 4-Bay Rear Backplane X40 RAID Cable Kit
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 1 | The 8i RAID/HBA adapter on the internal riser card
|
SAS 1 connector on the SAS/SATA backplane 1 | The 8i RAID/HBA adapter on the internal riser card
| |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | The 8i RAID/HBA adapter on riser card 1
|
SAS 1 connector on the SAS/SATA backplane 2 | The 8i RAID/HBA adapter on riser card 1
| |
5 SAS signal cable | SAS connector on the rear backplane | The 8i RAID/HBA adapter on riser card 2
|
Configuration 7: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one middle drive cage (SAS/SATA), one 24i RAID adapter
This configuration supports one middle 2.5-inch drive cage with two 4 x 2.5-inch SAS/SATA drive backplanes.
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 1 | Connector C0 on the RAID adapter |
SAS 1 connector on the SAS/SATA backplane 1 | Connector C1 on the RAID adapter | |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | Connector C2 on the RAID adapter |
SAS 1 connector on the SAS/SATA backplane 2 | Connector C3 on the RAID adapter | |
5 SAS signal cable | SAS connector on the middle backplane 1 | Connector C4 on the RAID adapter |
6 SAS signal cable | SAS connector on the middle backplane 2 | Connector C5 on the RAID adapter |
Configuration 8: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one middle drive cage (SAS/SATA), two RAID/HBA adapters (8i+16i)
This configuration supports one middle 2.5-inch drive cage with two 4 x 2.5-inch SAS/SATA drive backplanes.
When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:
For cable 3 and 4: ThinkSystem SR655 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
For cable 5 and 6: ThinkSystem SR655 2.5" & 3.5" SAS/SATA 4/8-Bay Middle Backplane X40 RAID Cable Kit
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 1 | The 16i RAID/HBA adapter
|
SAS 1 connector on the SAS/SATA backplane 1 | The 16i RAID/HBA adapter
| |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | The 16i RAID/HBA adapter
|
SAS 1 connector on the SAS/SATA backplane 2 | The 16i RAID/HBA adapter
| |
5 SAS signal cable | SAS connector on the middle backplane 1 | The 8i RAID/HBA adapter
|
6 SAS signal cable | SAS connector on the middle backplane 2 | The 8i RAID/HBA adapter
|
Configuration 9: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one middle drive cage (SAS/SATA), three 8i RAID/HBA adapters
This configuration supports one middle 2.5-inch drive cage with two 4 x 2.5-inch SAS/SATA drive backplanes.
When a Gen 4 RAID/HBA adapter is installed, ensure that you use the corresponding Gen 4 cable:
For cable 3 and 4: ThinkSystem SR655 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
For cable 5 and 6: ThinkSystem SR655 2.5" & 3.5" SAS/SATA 4/8-Bay Middle Backplane X40 RAID Cable Kit
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 1 | The 8i RAID/HBA adapter on the internal riser card
|
SAS 1 connector on the SAS/SATA backplane 1 | The 8i RAID/HBA adapter on the internal riser card
| |
4 SAS signal cable | SAS 0 connector on the SAS/SATA backplane 2 | The 8i RAID/HBA adapter on riser card 1
|
SAS 1 connector on the SAS/SATA backplane 2 | The 8i RAID/HBA adapter on riser card 1
| |
5 SAS signal cable | SAS connector on the middle backplane 1 | The 8i RAID/HBA adapter on riser card 2
|
6 SAS signal cable | SAS connector on the middle backplane 2 | The 8i RAID/HBA adapter on riser card 2
|
Configuration 10: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one rear drive cage (SAS/SATA), one 32i RAID adapter
This configuration supports one rear 2.5-inch drive cage with a 4 x 2.5-inch SAS/SATA drive backplane.
The 32i RAID adapter belongs to Gen 4. Ensure that you use the corresponding Gen 4 cable:
For cable 3 and 4: ThinkSystem SR655 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
For cable 5: ThinkSystem SR655 2.5" & 3.5" SAS/SATA 4-Bay Rear Backplane X40 RAID Cable Kit
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 and SAS 1 connectors on the SAS/SATA backplane 1 | Connector C0 on the RAID adapter |
4 SAS signal cable | SAS 0 and SAS 1 connectors on the SAS/SATA backplane 2 | Connector C1 on the RAID adapter |
5 SAS signal cable | SAS connector on the rear backplane | Connector C3 on the RAID adapter |
Configuration 11: three front backplanes (8 NVMe + 2 x 8 SAS/SATA), one middle drive cage (SAS/SATA), one 32i RAID adapter
This configuration supports one middle 2.5-inch drive cage with two 4 x 2.5-inch SAS/SATA drive backplanes.
The 32i RAID adapter belongs to Gen 4. Ensure that you use the corresponding Gen 4 cable:
For cable 3 and 4: ThinkSystem SR655 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
For cable 5: ThinkSystem SR655 2.5" & 3.5" SAS/SATA 4/8-Bay Middle Backplane X40 RAID Cable Kit
Cable | From | To |
---|---|---|
1 NVMe signal cable | NVMe 0-1 connector on the NVMe backplane | PCIe connector 1 on the system board |
NVMe 2-3 connector on the NVMe backplane | PCIe connector 2 on the system board | |
2 NVMe signal cable | NVMe 4-5 connector on the NVMe backplane | PCIe connector 3 on the system board |
NVMe 6-7 connector on the NVMe backplane | PCIe connector 4 on the system board | |
3 SAS signal cable | SAS 0 and SAS 1 connectors on the SAS/SATA backplane 1 | Connector C0 on the RAID adapter |
4 SAS signal cable | SAS 0 and SAS 1 connectors on the SAS/SATA backplane 2 | Connector C1 on the RAID adapter |
5 SAS signal cable | SAS connector on the middle backplane 1 | Connector C3 on the RAID adapter |
SAS connector on the middle backplane 2 |