Install the venting block (CPU complex)

Follow instructions in this section to install the venting block. The procedure must be executed by a trained technician.

About this task

Attention
  • Read Installation Guidelines and Safety inspection checklist to ensure that you work safely.
  • Touch the static-protective package that contains the component to any unpainted metal surface on the server; then, remove it from the package and place it on a static-protective surface.

Procedure

  1. Install the venting block to riser 1 or riser 2 slot depending on the configuration.
  2. Align the venting block with the screw holes on the CPU complex; then, fasten the two M2 screws (PH1, 2 x M2, 0.2 newton-meters, 1.7 inch-pounds) to secure the venting block.
    Figure 1. Venting block installation
    Venting block installation

After you finish

  1. If applicable, reinstall the PCIe riser assembly(ies). See Install a PCIe riser assembly.
  2. Reinstall the processor air baffle. See Install the processor air baffle.
  3. Reinstall the rear top cover. See Install the rear top cover.
  4. Reinstall the front top cover. See Install the front top cover.
  5. Complete the parts replacement. See Complete the parts replacement.