Removing the ServeRAID M5120 SAS/SATA Controller for System x
Use this information to remove the ServeRAID M5120 SAS/SATA Controller.
To remove a ServeRAID M5120 SAS/SATA controller, complete the following steps:
- Read the safety information and installation guidelines, see Safety and Installation guidelines.
- Turn off the server (see Turning off the server) and all attached peripheral devices. Disconnect all power cords; then, disconnect all external cables as necessary to replace the device.
- Remove the top cover (see Removing the server top cover).
- Remove the adapter from the system board.
- Disconnect the cables from the existing adapter.
- Disconnect the cable from the RAID cache card, if a cache card is installed on the adapter.
- Carefully grasp the adapter by the edges and pull it out of the connector on the system board.
- Remove the RAID cache card from the adapter (see Removing a RAID cache card).
- Go tostep 6.
- Remove the adapter from the PCIe riser-card assembly.
- Disconnect the cables from the existing adapter.
- Disconnect the cable from the RAID cache card, if a cache card is installed on the adapter.
- Carefully grasp the riser card by the blue touch points and pull it up until the riser-card assembly disengages from the connector on the system board and set it aside.
- Carefully grasp the adapter and pull it out of the riser-card assembly.
- Remove the RAID cache card from the adapter (see Removing a RAID cache card).
- If you are instructed to return the adapter, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.
Give documentation feedback