Skip to main content

6 x 2.5'' SAS/SATA + 2 x 2.5'' AnyBay + 2 x 2.5'' NVMe (Gen 5)

See this section to understand the cable routing of six front SAS/SATA drives, two front AnyBay drives and two front NVMe drives with the 10 x 2.5'' AnyBay backplane (Gen 5) installed.

To connect cables for a 7mm drive backplane, refer to 7mm drive backplane.

To connect cables for M.2 drives, refer to M.2 drive backplane.

To connect cables for rear NVMe drives, refer to Rear NVMe backplane cable routing with 10 x 2.5'' AnyBay backplane (Gen 5) installed.

To connect signal cables for a backplane for standard six front SAS/SATA drives, two AnyBay drives and two front NVMe drives, refer to the following cable routing scenarios depending on your server configuration:

Cable routing for onboard configuration

The following tables show the mapping relationship between backplane connectors and processor board connectors for onboard configuration.

Figure 1. Cable routing for onboard configuration of six SAS/SATA drives and two AnyBay and two NVMe front drives bays

Table 1. Mapping between one front AnyBay backplane and processor board for onboard configuration
BackplaneFromTo
Front BP (SAS)1 SAS 0–31 SATA 0
Front BP (power)2 Power and sideband2 Power port for front BP
Front BP (SAS)3 SAS 4–7, 8–93 SATA 1
Front BP (NVMe)4 NVMe 6–74 PCIe 2
5 NVMe 8–95 PCIe 1

Cable routing with an SFF HBA/RAID adapter

The following tables show the mapping relationship between backplane connectors and an SFF HBA/RAID adapter.

Figure 2. Cable routing for six SAS/SATA drives and two AnyBay drives and two NVMe front drive bays with a 16i SFF RAID adapter (Gen 4)

Table 2. Mapping between one front AnyBay backplane and an SFF HBA/RAID adapter
BackplaneFromTo
Front BP (SAS)1 SAS 0–3, 4–71 C0
Front BP (power)2 Power and sideband2 Power port for front BP
Front BP (NVMe)3 NVMe 6–73 PCIe 2
4 NVMe 8–94 PCIe 1
Figure 3. Cable routing for six SAS/SATA drives and two AnyBay drives and two NVMe front drive bays with a 16i SFF RAID adapter (Gen 3)

Table 3. Mapping between one front AnyBay backplane and an SFF HBA/RAID adapter
BackplaneFromTo
Front BP (SAS)1 SAS 0–3, 4–71 C0, C1
Front BP (power)2 Power and sideband2 Power port for front BP
Front BP (NVMe)3 NVMe 6–73 PCIe 2
4 NVMe 8–94 PCIe 1

Cable routing with a CFF HBA/RAID adapter

The following tables show the mapping relationship between backplane connectors and a 16i CFF HBA/RAID adapter (Gen 3 or Gen 4).

Figure 4. Cable routing for six SAS/SATA drives and two AnyBay drives and two NVMe front drive bays with a 16i CFF HBA/RAID adapter (Gen 3 or Gen 4)

Table 4. Mapping between one front SAS/SATA backplane and a CFF RAID adapter
Backplane/adapterFromTo
Front BP (SAS)1 SAS 0–31 C0
2 SAS 4–72 C1
CFF RAID adapter3 MB input3 PCIe 3
Front BP (power)4 Power and sideband4 Power port for front BP
Front BP (NVMe)5 NVMe 6–75 PCIe 2
6 NVMe 8–96 PCIe 1