A136F1000 : This message is for the use case when an implementation has detected a Front Panel NMI / Diagnostic Interrupt.

This message is for the use case when an implementation has detected a Front Panel NMI / Diagnostic Interrupt.

Front Panel NMI/Diagnostic Interrupt

Severity

Error

Serviceable

Yes

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Log in to the BMC Web interface and navigate to Settings > Capture BSOD.
  2. Check the system snapshot taken by the BMC.
    • If you have triggered the NMI yourself in the management console.
      1. Save the snapshot for future crash analysis.
      2. Restart the system.
    • If you have no idea why the system crashed.
      1. Analyze the errors in the snapshot and take appropriate action.
      2. Restart the system and check whether it has returned to normal operating state.
      3. If any problem persists, collect the system snapshot and any service data logs from the management console and contact Lenovo Support (https://datacentersupport.lenovo.com/serviceprovider).