2.5-inch drive backplane cable routing
Follow the instructions in this section to learn how to do cable routing for the 2.5-inch drive backplane.
2.5-inch drive backplane cable routing
Connect power cable and signal cables to the 2.5-inch drive backplane according to the corresponding sections:
2.5-inch drive backplane power cable routing
According to the configuration of front riser assemblies, see the corresponding section for the 2.5-inch drive power cable routing:
x8/x8/x8/x8 configuration
![]() | |||
From | Cable wall | To | Cable length |
1 Power connector on 2.5-inch drive backplane | Left cable wall | 1 Power connector 14 on processor board | 900 mm |
x16/x16 configuration
![]() | |||
From | Cable wall | To | Cable length |
1 Power connector on 2.5-inch drive backplane | Left cable wall | 1 Power connector 12 on processor board | 900 mm |
2.5-inch drive backplane signal cable routing
According to the configuration, see the corresponding section for the 2.5-inch drive signal cable routing:
- SAS/SATA or AnyBay (Tri-Mode) backplane to SFF RAID adapter
- SAS/SATA or AnyBay (Tri-Mode) backplane to internal CFF RAID adapter (with one processor installed)
- SAS/SATA or AnyBay (Tri-Mode) backplane to internal CFF RAID adapter (with two processors installed)
- NVMe backplane
- AnyBay backplane to SFF RAID adapter
- AnyBay backplane to internal CFF RAID adapter
SAS/SATA or AnyBay backplane to SFF RAID adapter
![]() | |||
From | Cable wall | To | Cable length |
1 SAS connector on 2.5-inch drive backplane | Left cable wall | 1
| 1020 mm |
SAS/SATA or AnyBay (Tri-mode) backplane to internal CFF RAID adapter (with one processor installed)
![]() | |||
From | Cable wall | To (internal CFF RAID adapter) | Cable length |
1 SAS connector on 2.5-inch drive backplane | N/A | 1a C0 connector | 140/140 mm |
1b C1 connector | |||
2 PCIe connector 10 on processor board | Right cable wall | 2 CFF input connector | 900 mm |
3a Internal RAID power connector on processor board | N/A | 3 Power connector | 300/800 mm |
3b Power connector 10 on processor board | Right cable wall |
SAS/SATA or AnyBay backplane to internal CFF RAID adapter (with two processors installed)
![]() | |||
From | Cable wall | To (internal CFF RAID adapter) | Cable length |
1 SAS connector on 2.5-inch drive backplane | N/A | 1a C0 connector | 140/140 mm |
1b C1 connector | |||
2 PCIe connector 14 on processor board | Left cable wall | 2 CFF input connector | 900 mm |
3 Internal RAID power connector on processor board | N/A | 3 Power connector | 300 mm |
NVMe backplane
![]() | |||
From (drive backplane) | Cable wall | To (processor board) | Cable length |
1 NVMe 0-1 connector | Left cable wall | 1 PCIe connector 15A | 800 mm |
2 NVMe 2-3 connector | Left cable wall | 2 PCIe connector 15B | 800 mm |
3 NVMe 4-5 connector | Right cable wall | 3 PCIe connector 9B | 800 mm |
4 NVMe 6-7 connector | Right cable wall | 4 PCIe connector 9A | 800 mm |
AnyBay backplane to SFF RAID adapter
SAS/SATA cable | NVMe cable | ||||||
![]() | ![]() | ||||||
From | Cable wall | To | Cable length | From (drive backplane) | Cable wall | To (processor board) | Cable length |
1 SAS connector on 2.5-inch drive backplane | Left cable wall | 1
| 1020 mm | 1 NVMe 0-1 connector | Left cable wall | 1 PCIe connector 15A | 800 mm |
2 NVMe 2-3 connector | Left cable wall | 2 PCIe connector 15B | 800 mm | ||||
3 NVMe 4-5 connector | Right cable wall | 3 PCIe connector 9B | 800 mm | ||||
4 NVMe 6-7 connector | Right cable wall | 4 PCIe connector 9A | 800 mm |
AnyBay backplane to internal CFF RAID adapter
SAS/SATA cable | NVMe cable | ||||||
![]() | ![]() | ||||||
From | Cable wall | To (internal CFF RAID adapter) | Cable length | From (drive backplane) | Cable wall | To (processor board) | Cable length |
1 SAS connector on 2.5-inch drive backplane | N/A | 1a C0 connector | 140/140 mm | 1 NVMe 0-1 connector | Left cable wall | 1 PCIe connector 15A | 800 mm |
1b C1 connector | 2 NVMe 2-3 connector | Left cable wall | 2 PCIe connector 15B | 800 mm | |||
2 PCIe connector 14 on processor board | Left cable wall | 2 CFF input connector | 900 mm | 3 NVMe 4-5 connector | Right cable wall | 3 PCIe connector 9B | 800 mm |
3 Internal RAID power connector on processor board | N/A | 3 Power connector | 300 mm | 4 NVMe 6-7 connector | Right cable wall | 4 PCIe connector 9A | 800 mm |
Give documentation feedback