Skip to main content

2.5-inch drive backplane cable routing

Follow the instructions in this section to learn how to do cable routing for the 2.5-inch drive backplane.

2.5-inch drive backplane cable routing​

Connect power cable and signal cables to the 2.5-inch drive backplane according to the corresponding sections:

2.5-inch drive backplane power cable routing​

x8/x8/x8/x8 configuration​



FromCable wallToCable length
1 Power connector on 2.5-inch drive backplaneLeft cable wall1 Power connector 14 on processor board900 mm

x16/x16 + SAS/SATA backplane configuration​



FromCable wallToCable length
1 Power connector on 2.5-inch drive backplaneLeft cable wall1 Power connector 14 on processor board900 mm

x16/x16 + NVMe/AnyBay backplane configuration​



FromCable wallToCable length
1 Power connector on 2.5-inch drive backplaneLeft cable wall1 Power connector 12 on processor board900 mm

x16/x16 + NVMe backplane to 960W-32i RAID adapter configuration​



FromCable wallToCable length
1 Power connector on 2.5-inch drive backplaneLeft cable wall1 Power connector 14 on processor board900 mm

2.5-inch drive backplane signal cable routing​

SAS/SATA or AnyBay (Tri-mode) backplane to SFF RAID adapter​



FromCable wallToCable length
1 SAS connector on 2.5-inch drive backplaneLeft cable wall1
  • Gen3 RAID adapter: C0C1 connector
  • Gen4 RAID adapter: C0 connector
1020 mm

SAS/SATA or AnyBay (Tri-mode) backplane to internal CFF RAID adapter (1 CPU)​



FromCable wallTo (internal CFF RAID adapter)Cable length
1 SAS connector on 2.5-inch drive backplaneN/A1a C0 connector140/140 mm
1b C1 connector
2 PCIe connector 10 on processor boardRight cable wall2 CFF input connector900 mm
3a Internal RAID power connector on processor boardN/A3 Power connector300/800 mm
3b Power connector 10 on processor boardRight cable wall

SAS/SATA or AnyBay (Tri-mode) backplane to internal CFF RAID adapter (1CPU + front high watts GPU)​



FromCable wallTo (internal CFF RAID adapter)Cable length
1 SAS connector on 2.5-inch drive backplaneN/A1a C0 connector140/140 mm
1b C1 connector
2 PCIe connector 10 on processor boardLeft cable wall2 CFF input connector900 mm
3a Internal RAID power connector on processor boardN/A3 Power connector300/800 mm
3b Power connector 10 on processor boardRight cable wall

SAS/SATA or AnyBay (Tri-mode) backplane to internal CFF RAID adapter (2 CPU)​



FromCable wallTo (internal CFF RAID adapter)Cable length
1 SAS connector on 2.5-inch drive backplaneN/A1a C0 connector140/140 mm
1b C1 connector
2 PCIe connector 14 on processor boardLeft cable wall2 CFF input connector900 mm
3 Internal RAID power connector on processor boardN/A3 Power connector300 mm

NVMe backplane without front high watts GPU​



From (drive backplane)Cable wallTo (processor board)Cable length
1 NVMe 0-1 connectorLeft cable wall1 PCIe connector 15A800 mm
2 NVMe 2-3 connectorLeft cable wall2 PCIe connector 15B800 mm
3 NVMe 4-5 connectorRight cable wall3 PCIe connector 9B800 mm
4 NVMe 6-7 connectorRight cable wall4 PCIe connector 9A800 mm

NVMe backplane with front high watts GPU​



From (drive backplane)Cable wallTo (processor board)Cable length
1 NVMe 0-1 connectorLeft cable wall1 PCIe connector 15A800 mm
2 NVMe 2-3 connectorLeft cable wall2 PCIe connector 15B800 mm
3 NVMe 4-5 connectorN/A3 PCIe connector 8550 mm
4 NVMe 6-7 connectorN/A4 PCIe connector 7550 mm

NVMe backplane to 960W-32i RAID adapter + front GPU ≤ 450W​



From (drive backplane)Cable wallTo (RAID adapter)Cable length
1a NVMe 0-1 connectorLeft cable wall1 C01100/1100/1100/1100 mm
1b NVMe 2-3 connector
1c NVMe 4-5 connector
1d NVMe 6-7 connector

NVMe backplane to 960W-32i RAID adapter + front GPU > 450W​



From (drive backplane)Cable wallTo (RAID adapter)Cable length
1a NVMe 0-1 connectorLeft cable wall1 C01100/1100 mm
1b NVMe 2-3 connector
2a NVMe 4-5 connectorLeft cable wall2 C11100/1100 mm
2b NVMe 6-7 connector

AnyBay backplane to SFF RAID adapter​

SAS/SATA cable


FromCable wallToCable length
1 SAS connector on 2.5-inch drive backplaneLeft cable wall1
  • Gen3 RAID adapter: C0C1 connector
  • Gen4 RAID adapter: C0 connector
1020 mm


From (drive backplane)Cable wallTo (processor board)Cable length
1 NVMe 0-1 connectorLeft cable wall1 PCIe connector 15A800 mm
2 NVMe 2-3 connectorLeft cable wall2 PCIe connector 15B800 mm
3 NVMe 4-5 connectorRight cable wall3 PCIe connector 9B800 mm
4 NVMe 6-7 connectorRight cable wall4 PCIe connector 9A800 mm

AnyBay backplane to internal CFF RAID adapter​

SAS/SATA cableNVMe cable




Note
NVMe cable 3 and 4 are not required in configurations with front high watts GPU adapters.
FromCable wallTo (internal CFF RAID adapter)Cable lengthFrom (drive backplane)Cable wallTo (processor board)Cable length
1 SAS connector on 2.5-inch drive backplaneN/A1a C0 connector140/140 mm1 NVMe 0-1 connectorLeft cable wall1 PCIe connector 15A800 mm
1b C1 connector2 NVMe 2-3 connectorLeft cable wall2 PCIe connector 15B800 mm
2 PCIe connector 14 on processor boardLeft cable wall2 CFF input connector900 mm3 NVMe 4-5 connectorRight cable wall3 PCIe connector 9B800 mm
3 Internal RAID power connector on processor boardN/A3 Power connector300 mm4 NVMe 6-7 connectorRight cable wall4 PCIe connector 9A800 mm