80010701-1406ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.
May also be shown as 800107011406ffff or 0x800107011406ffff
Severity
Warning
Alert Category
Warning - Temperature
Serviceable
Yes
SNMP Trap ID
12
Automatically Notify Support
No
User Response
- Check the IMM event log for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Ensure system cover is latched properly.
- Make sure that the room temperature is within operating specifications.