80070603-0701ffff : Sensor [SensorElementName] has transitioned to non-recoverable.

Sensor [SensorElementName] has transitioned to non-recoverable.

IMM has detected Voltage Regulator Error.

May also be shown as 800706030701ffff or 0x800706030701ffff

Severity

Error

Alert Category

Critical - Power

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0530

SNMP Trap ID

4

Automatically Notify Support

No

User Response

  • CPU 1 VRD: Indicates a problem with either the voltage regulator for CPU1 or CPU 1 itself
  • CPU 2 VRD: Indicates a problem with either the voltage regulator for CPU2 or CPU 2 itself
  • DIMM 01-06 VRD: Indicates a problem with either the voltage regulator for DIMMs 1-6 or 1 or more of the following components: DIMM1-DIMM6
  • DIMM 07-12 VRD: Indicates a problem with either the voltage regulator for DIMMs 7-12 or 1 or more of the following components: DIMM7-DIMM12
  • DIMM 13-18 VRD: Indicates a problem with either the voltage regulator for DIMMs 13-18 or 1 or more of the following components: DIMM13-DIMM18
  • DIMM 19-24 VRD: Indicates a problem with either the voltage regulator for DIMMs 19-24 or 1 or more of the following components: DIMM19-DIMM24
  • MainBrd ENET VRD: Indicates a problem with either the voltage regulator for the onboard Ethernet or ML2 card
  • MainBrd SAS VRD: Indicates a problem with either the voltage regulator for the onboard SAS or the RAID cache card
  • MainBrd VRD: Indicates a problem with a voltage regulator for the system board
  • System VRD: Indicates a problem with either a voltage regulator for the system board or the microprocessor and memory expansion tray
  1. Check the IMM Web event log. This event may be a symptom of an earlier error.
  2. Depending on the error perform the following steps.

For a CPU 1 VRD or CPU 2 VRD error:

  1. Replace system board.
  2. Replace affected microprocessor.

For a DIMM 01-06 VRD, DIMM 07-12 VRD, DIMM 13-18 VRD, or DIMM 19-24 VRD error:

  1. Replace DIMM(s) associated with error.
  2. Replace system board.

For a MainBrd ENET VRD error:

  1. Replace the ML2 Ethernet Adapter if installed.
  2. Replace system board.

For a MainBrd SAS VRD error:

  1. Replace the RAID cache card if installed.
  2. Replace system board.

For a MainBrd VRD error:

  1. Replace system board.

For a System VRD error:

  1. Replace microprocessor and memory expansion tray if installed.