80070603-0701ffff : Sensor [SensorElementName] has transitioned to non-recoverable.
Sensor [SensorElementName] has transitioned to non-recoverable.
IMM has detected Voltage Regulator Error.
May also be shown as 800706030701ffff or 0x800706030701ffff
Severity
Error
Alert Category
Critical - Power
Serviceable
Yes
SNMP Trap ID
4
Automatically Notify Support
No
User Response
- CPU 1 VRD: Indicates a problem with either the voltage regulator for CPU1 or CPU 1 itself
- CPU 2 VRD: Indicates a problem with either the voltage regulator for CPU2 or CPU 2 itself
- DIMM 01-06 VRD: Indicates a problem with either the voltage regulator for DIMMs 1-6 or 1 or more of the following components: DIMM1-DIMM6
- DIMM 07-12 VRD: Indicates a problem with either the voltage regulator for DIMMs 7-12 or 1 or more of the following components: DIMM7-DIMM12
- DIMM 13-18 VRD: Indicates a problem with either the voltage regulator for DIMMs 13-18 or 1 or more of the following components: DIMM13-DIMM18
- DIMM 19-24 VRD: Indicates a problem with either the voltage regulator for DIMMs 19-24 or 1 or more of the following components: DIMM19-DIMM24
- MainBrd ENET VRD: Indicates a problem with either the voltage regulator for the onboard Ethernet or ML2 card
- MainBrd SAS VRD: Indicates a problem with either the voltage regulator for the onboard SAS or the RAID cache card
- MainBrd VRD: Indicates a problem with a voltage regulator for the system board
- System VRD: Indicates a problem with either a voltage regulator for the system board or the microprocessor and memory expansion tray
- Check the IMM Web event log. This event may be a symptom of an earlier error.
- Depending on the error perform the following steps.
For a CPU 1 VRD or CPU 2 VRD error:
- Replace system board.
- Replace affected microprocessor.
For a DIMM 01-06 VRD, DIMM 07-12 VRD, DIMM 13-18 VRD, or DIMM 19-24 VRD error:
- Replace DIMM(s) associated with error.
- Replace system board.
For a MainBrd ENET VRD error:
- Replace the ML2 Ethernet Adapter if installed.
- Replace system board.
For a MainBrd SAS VRD error:
- Replace the RAID cache card if installed.
- Replace system board.
For a MainBrd VRD error:
- Replace system board.
For a System VRD error:
- Replace microprocessor and memory expansion tray if installed.
- Replace system board.
Give documentation feedback