Skip to main content

80010901-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

IMM has detected that the ambient temperature has risen above its upper critical threshold.

May also be shown as 800109012701ffff or 0x800109012701ffff

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0494

SNMP Trap ID

0

Automatically Notify Support

No

User Response

  1. Check event log for any fan or cooling related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  3. Ensure system cover is latched properly.
  4. Make sure that the room temperature is within operating specifications.