80070301-0304ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.
IMM has detected that the temperature for CPU 4 has transitioned to a non recoverable state.
May also be shown as 800703010304ffff or 0x800703010304ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
Complete the following steps:
- Check the IMM event log for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Ensure system cover is latched properly.
- Make sure that the room temperature is within operating specifications.
- Make sure that the microprocessor 4 heat sink is securely installed.
- (Trained service technician only) Make sure that the microprocessor 4 heat sink is installed correctly and the thermal material is correctly applied.
- (Trained service technician only) Replace microprocessor 4.
Give documentation feedback