80070301-0b09ffff : IMM has detected that the temperature for ML2 card has transitioned to a non recoverable state.

IMM has detected that the temperature for ML2 card has transitioned to a non recoverable state.

IMM has detected that the temperature for ML2 Card has transitioned to a non recoverable state.

May also be shown as 800703010b09ffff or 0x800703010b09ffff

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0524

SNMP Trap ID

0

Automatically Notify Support

No

User Response

Complete the following steps:

  1. Check the IMM event log for any fan or cooling related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  3. Ensure system cover is latched properly.
  4. Make sure that the room temperature is within operating specifications.
  5. (Trained service technician only) Replace ML2 Card.