80010901-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
The PCH temperature sensor has risen above its upper critical threshold. A soft shutdown will be attempted.
May also be shown as 800109012d01ffff or 0x800109012d01ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
- Check IMM event log for any fan or cooling related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Ensure system cover is latched properly.
- Make sure that the room temperature is within operating specifications.
Give documentation feedback