800b0509-0a01ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient Resources for Power supply.
May also be shown as 800b05090a01ffff or 0x800b05090a01ffff
Severity
Error
Alert Category
Critical - Redundant Power Supply
Serviceable
Yes
SNMP Trap ID
9
Automatically Notify Support
No
User Response
- Power Unit: Check if Power Supply is missing, unplugged.
- Check the power supply LEDs, see "Power-supply LEDs"
- Replace the affected power supply.
- Check the power supply max rate and power capping policy, if the required power resource is not met, change the power supply or modify power capping mechanism.
Give documentation feedback