Skip to main content

800b0509-0a01ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient Resources for Power supply.

May also be shown as 800b05090a01ffff or 0x800b05090a01ffff

Severity

Error

Alert Category

Critical - Redundant Power Supply

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0810

SNMP Trap ID

9

Automatically Notify Support

No

User Response

  1. Power Unit: Check if Power Supply is missing, unplugged.
  2. Check the power supply LEDs, see "Power-supply LEDs"
  3. Replace the affected power supply.
  4. Check the power supply max rate and power capping policy, if the required power resource is not met, change the power supply or modify power capping mechanism.