Skip to main content

List of IMM events

This section lists all messages that can be sent from the IMM.

  • 40000001-00000000 : Management Controller [arg1] Network Initialization Complete.

    The IMM network subsystem initialization has completed.

    May also be shown as 4000000100000000 or 0x4000000100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - IMM Network event
    SNMP Trap ID
    37
    CIM Information
    Prefix: IMM ID: 0001
    User Response
    Information only; no action is required.
  • 40000002-00000000 : Certificate Authority [arg1] has detected a [arg2] Certificate Error.

    A problem has occurred with the SSL Server, SSL Client, or SSL Trusted CA certificate that has been imported into the IMM. The imported certificate must contain a public key that corresponds to the key pair that was previously generated by the Generate a New Key and Certificate Signing Request

    May also be shown as 4000000200000000 or 0x4000000200000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0002
    User Response
    Make sure that the certificate that you are importing is correct and properly generated.
  • 40000003-00000000 : Ethernet Data Rate modified from [arg1] to [arg2] by user [arg3].

    The specified user has changed the Ethernet data rate of the Integrated Management Module external network interface to the specified value.

    May also be shown as 4000000300000000 or 0x4000000300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0003
    User Response
    Information only; no action is required.
  • 40000004-00000000 : Ethernet Duplex setting modified from [arg1] to [arg2] by user [arg3].

    The specified user has changed the Ethernet duplex setting of the Integrated Management Module external network interface to the specified value.

    May also be shown as 4000000400000000 or 0x4000000400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0004
    User Response
    Information only; no action is required.
  • 40000005-00000000 : Ethernet MTU setting modified from [arg1] to [arg2] by user [arg3].

    The specified user has changed the Ethernet maximum transmission unit (MTU) setting of the Integrated Management Module external network interface to the specified value.

    May also be shown as 4000000500000000 or 0x4000000500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0005
    User Response
    Information only; no action is required.
  • 40000006-00000000 : Ethernet locally administered MAC address modified from [arg1] to [arg2] by user [arg3].

    The specified user has changed the Ethernet locally administered MAC address of the Integrated Management Module external network interface to the specified value

    May also be shown as 4000000600000000 or 0x4000000600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0006
    User Response
    Information only; no action is required.
  • 40000007-00000000 : Ethernet interface [arg1] by user [arg2].

    The specified user has enabled or disabled the Ethernet interface.

    May also be shown as 4000000700000000 or 0x4000000700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0007
    User Response
    Information only; no action is required.
  • 40000008-00000000 : Hostname set to [arg1] by user [arg2].

    The specified user has changed the Integrated Management Module host name.

    May also be shown as 4000000800000000 or 0x4000000800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - IMM Network event
    SNMP Trap ID
    37
    CIM Information
    Prefix: IMM ID: 0008
    User Response
    Information only; no action is required.
  • 40000009-00000000 : IP address of network interface modified from [arg1] to [arg2] by user [arg3].

    The specified user has changed the IP address of the Integrated Management Module external network interface to the specified value.

    May also be shown as 4000000900000000 or 0x4000000900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - IMM Network event
    SNMP Trap ID
    37
    CIM Information
    Prefix: IMM ID: 0009
    User Response
    Information only; no action is required.
  • 4000000a-00000000 : IP subnet mask of network interface modified from [arg1] to [arg2] by user [arg3].

    The specified user has changed the subnet mask of the Integrated Management Module external network interface to the specified value.

    May also be shown as 4000000a00000000 or 0x4000000a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0010
    User Response
    Information only; no action is required.
  • 4000000b-00000000 : IP address of default gateway modified from [arg1] to [arg2] by user [arg3].

    The specified user has changed the gateway address of the Integrated Management Module external network interface to the specified value.

    May also be shown as 4000000b00000000 or 0x4000000b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0011
    User Response
    Information only; no action is required.
  • 4000000c-00000000 : OS Watchdog response [arg1] by [arg2] .

    This message is for the use case where an OS Watchdog has been enabled or disabled by a user.

    May also be shown as 4000000c00000000 or 0x4000000c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0012
    User Response
    Information only; no action is required.
  • 4000000d-00000000 : DHCP[[arg1]] failure, no IP address assigned.

    A DHCP server has failed to assign an IP address to the IMM.

    May also be shown as 4000000d00000000 or 0x4000000d00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0013
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the IMM network cable is connected.
    2. Make sure that there is a DHCP server on the network that can assign an IP address to the IMM.
  • 4000000e-00000000 : Remote Login Successful. Login ID: [arg1] from [arg2] at IP address [arg3].

    The specified user has logged in to the Integrated Management Module.

    May also be shown as 4000000e00000000 or 0x4000000e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0014
    User Response
    Information only; no action is required.
  • 4000000f-00000000 : Attempting to [arg1] server [arg2] by user [arg3].

    This message is for the use case where a user is using the Management Controller to perform a power function on the system.

    May also be shown as 4000000f00000000 or 0x4000000f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0015
    User Response
    Information only; no action is required.
  • 40000010-00000000 : Security: Userid: [arg1] had [arg2] login failures from WEB client at IP address [arg3].

    A user has exceeded the maximum allowed number of unsuccessful login attempts from a web browser and has been prevented from logging in for the lockout period.

    May also be shown as 4000001000000000 or 0x4000001000000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0016
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the correct login ID and password are being used.
    2. Have the system administrator reset the login ID or password.
  • 40000011-00000000 : Security: Login ID: [arg1] had [arg2] login failures from CLI at [arg3].

    A user has exceeded the maximum allowed number of unsuccessful login attempts from the command-line interface and has been prevented from logging in for the lockout period.

    May also be shown as 4000001100000000 or 0x4000001100000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0017
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the correct login ID and password are being used.
    2. Have the system administrator reset the login ID or password.
  • 40000012-00000000 : Remote access attempt failed. Invalid userid or password received. Userid is [arg1] from WEB browser at IP address [arg2].

    A user has attempted to log in from a web browser by using an invalid login ID or password.

    May also be shown as 4000001200000000 or 0x4000001200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0018
    User Response
    Make sure that the correct login ID and password are being used.
  • 40000013-00000000 : Remote access attempt failed. Invalid userid or password received. Userid is [arg1] from TELNET client at IP address [arg2].

    A user has attempted to log in from a Telnet session by using an invalid login ID or password.

    May also be shown as 4000001300000000 or 0x4000001300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0019
    User Response
    Make sure that the correct login ID and password are being used.
  • 40000014-00000000 : The [arg1] on system [arg2] cleared by user [arg3].

    The specified user has deleted system log events or audit log events.

    May also be shown as 4000001400000000 or 0x4000001400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0020
    User Response
    Information only; no action is required.
  • 40000015-00000000 : Management Controller [arg1] reset was initiated by user [arg2].

    The Integrated Management Module has been reset. The logs provide additional details.

    May also be shown as 4000001500000000 or 0x4000001500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0021
    User Response
    Information only; no action is required.
  • 40000016-00000000 : ENET[[arg1]] DHCP-HSTN=[arg2], DN=[arg3], IP@=[arg4], SN=[arg5], GW@=[arg6], DNS1@=[arg7] .

    The DHCP server has assigned an IMM IP address and configuration.

    May also be shown as 4000001600000000 or 0x4000001600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0022
    User Response
    Information only; no action is required.
  • 40000017-00000000 : ENET[[arg1]] IP-Cfg:HstName=[arg2], IP@=[arg3] ,NetMsk=[arg4], GW@=[arg5] .

    An IMM IP address and configuration have been assigned using client data.

    May also be shown as 4000001700000000 or 0x4000001700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0023
    User Response
    Information only; no action is required.
  • 40000018-00000000 : LAN: Ethernet[[arg1]] interface is no longer active.

    The IMM Ethernet interface has been disabled.

    May also be shown as 4000001800000000 or 0x4000001800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0024
    User Response
    Information only; no action is required.
  • 40000019-00000000 : LAN: Ethernet[[arg1]] interface is now active.

    The IMM Ethernet interface has been enabled.

    May also be shown as 4000001900000000 or 0x4000001900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0025
    User Response
    Information only; no action is required.
  • 4000001a-00000000 : DHCP setting changed to [arg1] by user [arg2].

    The specified user has changed the DHCP setting of the Integrated Management Module external network interface.

    May also be shown as 4000001a00000000 or 0x4000001a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0026
    User Response
    Information only; no action is required.
  • 4000001b-00000000 : Management Controller [arg1]: Configuration restored from a file by user [arg2].

    The specified user has restored the Integrated Management Module (IMM) configuration from a previously saved configuration file. Some configuration settings might require that the IMM be restarted before they take effect.

    May also be shown as 4000001b00000000 or 0x4000001b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0027
    User Response
    Information only; no action is required.
  • 4000001c-00000000 : Watchdog [arg1] Screen Capture Occurred .

    An operating-system error has occurred, and the screen capture was successful.

    May also be shown as 4000001c00000000 or 0x4000001c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0028
    User Response
    If there was no operating-system error, complete the following steps until the problem is solved:
    1. Reconfigure the watchdog timer to a higher value.
    2. Make sure that the IMM Ethernet-over-USB interface is enabled.
    3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
    4. Disable the watchdog.
    If there was an operating-system error, check the integrity of the installed operating system.
  • 4000001d-00000000 : Watchdog [arg1] Failed to Capture Screen.

    An operating-system error has occurred, and the screen capture failed.

    May also be shown as 4000001d00000000 or 0x4000001d00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0029
    User Response
    Complete the following steps until the problem is solved:
    1. Reconfigure the watchdog timer to a higher value.
    2. Make sure that the IMM Ethernet over USB interface is enabled.
    3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
    4. Disable the watchdog.
    5. Check the integrity of the installed operating system.
    6. Update the IMM firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  • 4000001e-00000000 : Running the backup Management Controller [arg1] main application.

    The IMM was unable to run the primary IMM image and has resorted to running the backup image.

    May also be shown as 4000001e00000000 or 0x4000001e00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0030
    User Response
    Update the IMM firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  • 4000001f-00000000 : Please ensure that the Management Controller [arg1] is flashed with the correct firmware. The Management Controller is unable to match its firmware to the server.

    The server does not support the installed IMM firmware version.

    May also be shown as 4000001f00000000 or 0x4000001f00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0031
    User Response
    Update the IMM firmware to a version that the server supports. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  • 40000020-00000000 : Management Controller [arg1] Reset was caused by restoring default values.

    The default configuration has been restored to the Integrated Management Module.

    May also be shown as 4000002000000000 or 0x4000002000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0032
    User Response
    Information only; no action is required.
  • 40000021-00000000 : Management Controller [arg1] clock has been set from NTP server [arg2].

    The IMM clock has been set to the date and time that are provided by the Network Time Protocol server.

    May also be shown as 4000002100000000 or 0x4000002100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0033
    User Response
    Information only; no action is required.
  • 40000022-00000000 : SSL data in the Management Controller [arg1] configuruation data is invalid. Clearing configuration data region and disabling SSL.

    There is a problem with the certificate that has been imported into the IMM. The imported certificate must contain a public key that corresponds to the key pair that was previously generated through the Generate a New Key and Certificate Signing Request link.

    May also be shown as 4000002200000000 or 0x4000002200000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0034
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the certificate that you are importing is correct.
    2. Try to import the certificate again.
  • 40000023-00000000 : Flash of [arg1] from [arg2] succeeded for user [arg3] .

    The specified firmware update has been completed.

    May also be shown as 4000002300000000 or 0x4000002300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0035
    User Response
    Information only; no action is required.
  • 40000024-00000000 : Flash of [arg1] from [arg2] failed for user [arg3].

    The specified firmware has not been updated.

    May also be shown as 4000002400000000 or 0x4000002400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0036
    User Response
    Information only; no action is required.
  • 40000025-00000000 : The [arg1] on system [arg2] is 75% full.

    The IMM event log is 75% full. When the event log is completely full, the new entries will overwrite the oldest entries. To avoid losing older log entries, save the log as a text file and clear the log.

    May also be shown as 4000002500000000 or 0x4000002500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Event Log Fullness
    SNMP Trap ID
    35
    CIM Information
    Prefix: IMM ID: 0037
    User Response
    Information only; no action is required.
  • 40000026-00000000 : The [arg1] on system [arg2] is 100% full.

    The IMM event log is full. New entries in the log will overwrite the oldest entries. To avoid losing older log entries, save the log as a text file and clear the log.

    May also be shown as 4000002600000000 or 0x4000002600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Event Log Fullness
    SNMP Trap ID
    35
    CIM Information
    Prefix: IMM ID: 0038
    User Response
    To avoid losing older log entries, save the log as a text file and clear the log.
  • 40000027-00000000 : Platform Watchdog Timer expired for [arg1].

    A Platform Watchdog Timer Expired event has occurred.

    May also be shown as 4000002700000000 or 0x4000002700000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - OS Timeout
    SNMP Trap ID
    21
    CIM Information
    Prefix: IMM ID: 0039
    User Response
    Complete the following steps until the problem is solved:
    1. Reconfigure the watchdog timer to a higher value.
    2. Make sure that the IMM Ethernet-over-USB interface is enabled.
    3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
    4. Disable the watchdog.
    5. Check the integrity of the installed operating system.
  • 40000028-00000000 : Management Controller Test Alert Generated by [arg1].

    The Integrated Management Module has sent a test message to help verify connectivity.

    May also be shown as 4000002800000000 or 0x4000002800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0040
    User Response
    Information only; no action is required.
  • 40000029-00000000 : Security: Userid: [arg1] had [arg2] login failures from an SSH client at IP address [arg3].

    A user has exceeded the maximum number of unsuccessful login attempts from SSH and has been prevented from logging in for the lockout period.

    May also be shown as 4000002900000000 or 0x4000002900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0041
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the correct login ID and password are being used.
    2. Have the system administrator reset the login ID or password.
  • 4000002a-00000000 : [arg1] firmware mismatch internal to system [arg2]. Please attempt to flash the [arg3] firmware.

    A specific type of firmware mismatch has been detected.

    May also be shown as 4000002a00000000 or 0x4000002a00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0042
    User Response
    Reflash the IMM firmware to the latest version.
  • 4000002b-00000000 : Domain name set to [arg1].

    Domain name set by user

    May also be shown as 4000002b00000000 or 0x4000002b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0043
    User Response
    Information only; no action is required.
  • 4000002c-00000000 : Domain Source changed to [arg1] by user [arg2].

    Domain source changed by user

    May also be shown as 4000002c00000000 or 0x4000002c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0044
    User Response
    Information only; no action is required.
  • 4000002d-00000000 : DDNS setting changed to [arg1] by user [arg2].

    DDNS setting changed by user

    May also be shown as 4000002d00000000 or 0x4000002d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0045
    User Response
    Information only; no action is required.
  • 4000002e-00000000 : DDNS registration successful. The domain name is [arg1].

    The DDNS registration was successful.

    May also be shown as 4000002e00000000 or 0x4000002e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0046
    User Response
    Information only; no action is required.
  • 4000002f-00000000 : IPv6 enabled by user [arg1] .

    The specified user has enabled IPv6 support on the Integrated Management Module.

    May also be shown as 4000002f00000000 or 0x4000002f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0047
    User Response
    Information only; no action is required.
  • 40000030-00000000 : IPv6 disabled by user [arg1] .

    The specified user has disabled IPv6 support on the Integrated Management Module.

    May also be shown as 4000003000000000 or 0x4000003000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0048
    User Response
    Information only; no action is required.
  • 40000031-00000000 : IPv6 static IP configuration enabled by user [arg1].

    The specified user has enabled IPv6 static address assignment on the Integrated Management Module.

    May also be shown as 4000003100000000 or 0x4000003100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0049
    User Response
    Information only; no action is required.
  • 40000032-00000000 : IPv6 DHCP enabled by user [arg1].

    The specified user has enabled DHCPv6 on the Integrated Management Module.

    May also be shown as 4000003200000000 or 0x4000003200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0050
    User Response
    Information only; no action is required.
  • 40000033-00000000 : IPv6 stateless auto-configuration enabled by user [arg1].

    IPv6 stateless address auto-configuration has been enabled on the Integrated Management Module by the specified user.

    May also be shown as 4000003300000000 or 0x4000003300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0051
    User Response
    Information only; no action is required.
  • 40000034-00000000 : IPv6 static IP configuration disabled by user [arg1].

    The specified user has disabled IPv6 static address assignment on the Integrated Management Module.

    May also be shown as 4000003400000000 or 0x4000003400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0052
    User Response
    Information only; no action is required.
  • 40000035-00000000 : IPv6 DHCP disabled by user [arg1].

    The specified user has disabled DHCPv6 on the Integrated Management Module.

    May also be shown as 4000003500000000 or 0x4000003500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0053
    User Response
    Information only; no action is required.
  • 40000036-00000000 : IPv6 stateless auto-configuration disabled by user [arg1].

    IPv6 stateless address auto-configuration has been disabled on the Integrated Management Module by the specified user.

    May also be shown as 4000003600000000 or 0x4000003600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0054
    User Response
    Information only; no action is required.
  • 40000037-00000000 : ENET[[arg1]] IPv6-LinkLocal:HstName=[arg2], IP@=[arg3] ,Pref=[arg4] .

    The IPv6 link-local address is active.

    May also be shown as 4000003700000000 or 0x4000003700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0055
    User Response
    Information only; no action is required.
  • 40000038-00000000 : ENET[[arg1]] IPv6-Static:HstName=[arg2], IP@=[arg3] ,Pref=[arg4], GW@=[arg5] .

    The IPv6 static address is active.

    May also be shown as 4000003800000000 or 0x4000003800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0056
    User Response
    Information only; no action is required.
  • 40000039-00000000 : ENET[[arg1]] DHCPv6-HSTN=[arg2], DN=[arg3], IP@=[arg4], Pref=[arg5].

    The IPv6 DHCP-assigned address is active.

    May also be shown as 4000003900000000 or 0x4000003900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0057
    User Response
    Information only; no action is required.
  • 4000003a-00000000 : IPv6 static address of network interface modified from [arg1] to [arg2] by user [arg3].

    A user modifies the IPv6 static address of a Management Controller

    May also be shown as 4000003a00000000 or 0x4000003a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0058
    User Response
    Information only; no action is required.
  • 4000003b-00000000 : DHCPv6 failure, no IP address assigned.

    The DHCPv6 server has failed to assign an IP address to a management controller.

    May also be shown as 4000003b00000000 or 0x4000003b00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0059
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the IMM network cable is connected.
    2. Make sure that there is a DHCP6 server on the network that can assign an IP address to the IMM.
  • 4000003c-00000000 : Platform Watchdog Timer expired for [arg1].

    IMM has detected an OS did not start in the expected amount of time.

    May also be shown as 4000003c00000000 or 0x4000003c00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Loader timeout
    SNMP Trap ID
    26
    CIM Information
    Prefix: IMM ID: 0060
    User Response
    1. Reconfigure the watchdog timer to a higher value.
    2. Make sure that the IMM Ethernet over USB interface is enabled.
    3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
    4. Disable the watchdog.
    5. Check the integrity of the installed operating system.
  • 4000003d-00000000 : Telnet port number changed from [arg1] to [arg2] by user [arg3].

    The specified user has changed the Telnet port number.

    May also be shown as 4000003d00000000 or 0x4000003d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0061
    User Response
    Information only; no action is required.
  • 4000003e-00000000 : SSH port number changed from [arg1] to [arg2] by user [arg3].

    The specified user has changed the Secure Shell (SSH) port number.

    May also be shown as 4000003e00000000 or 0x4000003e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0062
    User Response
    Information only; no action is required.
  • 4000003f-00000000 : Web-HTTP port number changed from [arg1] to [arg2] by user [arg3].

    The specified user has changed the HTTP port number. New HTTP (web) connections must use the new port number.

    May also be shown as 4000003f00000000 or 0x4000003f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0063
    User Response
    Information only; no action is required.
  • 40000040-00000000 : Web-HTTPS port number changed from [arg1] to [arg2] by user [arg3].

    The specified user has changed the HTTPS port number. New HTTPS (secure web) connections must use the new port number.

    May also be shown as 4000004000000000 or 0x4000004000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0064
    User Response
    Information only; no action is required.
  • 40000041-00000000 : CIM/XML HTTP port number changed from [arg1] to [arg2] by user [arg3].

    The specified user has changed the CIM HTTP port number.

    May also be shown as 4000004100000000 or 0x4000004100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0065
    User Response
    Information only; no action is required.
  • 40000042-00000000 : CIM/XML HTTPS port number changed from [arg1] to [arg2] by user [arg3].

    The specified user has changed the CIM HTTPS port number.

    May also be shown as 4000004200000000 or 0x4000004200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0066
    User Response
    Information only; no action is required.
  • 40000043-00000000 : SNMP Agent port number changed from [arg1] to [arg2] by user [arg3].

    The specified user has changed the Simple Network Management Protocol (SNMP) agent port number.

    May also be shown as 4000004300000000 or 0x4000004300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0067
    User Response
    Information only; no action is required.
  • 40000044-00000000 : SNMP Traps port number changed from [arg1] to [arg2] by user [arg3].

    The specified user has changed the Simple Network Management Protocol (SNMP) traps port number.

    May also be shown as 4000004400000000 or 0x4000004400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0068
    User Response
    Information only; no action is required.
  • 40000045-00000000 : Syslog port number changed from [arg1] to [arg2] by user [arg3].

    A user has modified the Syslog receiver port number.

    May also be shown as 4000004500000000 or 0x4000004500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0069
    User Response
    Information only; no action is required.
  • 40000046-00000000 : Remote Presence port number changed from [arg1] to [arg2] by user [arg3].

    A user has modified the Remote Presence port number.

    May also be shown as 4000004600000000 or 0x4000004600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0070
    User Response
    Information only; no action is required.
  • 40000047-00000000 : LED [arg1] state changed to [arg2] by [arg3].

    The specified LED has changed state.

    May also be shown as 4000004700000000 or 0x4000004700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0071
    User Response
    Information only; no action is required.
  • 40000048-00000000 : Inventory data changed for device [arg1], new device data hash=[arg2], new master data hash=[arg3] .

    Something has caused the physical inventory to change

    May also be shown as 4000004800000000 or 0x4000004800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0072
    User Response
    Information only; no action is required.
  • 40000049-00000000 : SNMP [arg1] enabled by user [arg2] .

    The specified user has enabled the SNMPv1 or SNMPv3 agent.

    May also be shown as 4000004900000000 or 0x4000004900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0073
    User Response
    Information only; no action is required.
  • 4000004a-00000000 : SNMP [arg1] disabled by user [arg2] .

    The specified user has disabled the SNMPv1 or SNMPv3 agent.

    May also be shown as 4000004a00000000 or 0x4000004a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0074
    User Response
    Information only; no action is required.
  • 4000004b-00000000 : SNMPv1 [arg1] set by user [arg2]: Name=[arg3], AccessType=[arg4], Address=[arg5], .

    A user changed the SNMP community string

    May also be shown as 4000004b00000000 or 0x4000004b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0075
    User Response
    Information only; no action is required.
  • 4000004c-00000000 : LDAP Server configuration set by user [arg1]: SelectionMethod=[arg2], DomainName=[arg3], Server1=[arg4], Server2=[arg5], Server3=[arg6], Server4=[arg7].

    A user changed the LDAP server configuration

    May also be shown as 4000004c00000000 or 0x4000004c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0076
    User Response
    Information only; no action is required.
  • 4000004d-00000000 : LDAP set by user [arg1]: RootDN=[arg2], UIDSearchAttribute=[arg3], BindingMethod=[arg4], EnhancedRBS=[arg5], TargetName=[arg6], GroupFilter=[arg7], GroupAttribute=[arg8], LoginAttribute=[arg9].

    A user configured an LDAP Miscellaneous setting

    May also be shown as 4000004d00000000 or 0x4000004d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0077
    User Response
    Information only; no action is required.
  • 4000004e-00000000 : Serial Redirection set by user [arg1]: Mode=[arg2], BaudRate=[arg3], StopBits=[arg4], Parity=[arg5], SessionTerminateSequence=[arg6].

    A user configured the Serial Port mode

    May also be shown as 4000004e00000000 or 0x4000004e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0078
    User Response
    Information only; no action is required.
  • 4000004f-00000000 : Date and Time set by user [arg1]: Date=[arg2], Time-[arg3], DST Auto-adjust=[arg4], Timezone=[arg5].

    The specified user has changed the date and time in the Integrated Management Module.

    May also be shown as 4000004f00000000 or 0x4000004f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0079
    User Response
    Information only; no action is required.
  • 40000050-00000000 : Server General Settings set by user [arg1]: Name=[arg2], Contact=[arg3], Location=[arg4], Room=[arg5], RackID=[arg6], Rack U-position=[arg7].

    A user configured the Location setting

    May also be shown as 4000005000000000 or 0x4000005000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0080
    User Response
    Information only; no action is required.
  • 40000051-00000000 : Server Power Off Delay set to [arg1] by user [arg2].

    A user configured the Server Power Off Delay

    May also be shown as 4000005100000000 or 0x4000005100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0081
    User Response
    Information only; no action is required.
  • 40000052-00000000 : Server [arg1] scheduled for [arg2] at [arg3] by user [arg4].

    A user configured a Server Power action at a specific time

    May also be shown as 4000005200000000 or 0x4000005200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0082
    User Response
    Information only; no action is required.
  • 40000053-00000000 : Server [arg1] scheduled for every [arg2] at [arg3] by user [arg4].

    A user configured a recurring Server Power Action

    May also be shown as 4000005300000000 or 0x4000005300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0083
    User Response
    Information only; no action is required.
  • 40000054-00000000 : Server [arg1] [arg2] cleared by user [arg3].

    A user cleared a Server Power Action.

    May also be shown as 4000005400000000 or 0x4000005400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0084
    User Response
    Information only; no action is required.
  • 40000055-00000000 : Synchronize time setting by user [arg1]: Mode=[arg2], NTPServerHost=[arg3]:[arg4],NTPUpdateFrequency=[arg5].

    A user configured the Date and Time synchronize settings

    May also be shown as 4000005500000000 or 0x4000005500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0085
    User Response
    Information only; no action is required.
  • 40000056-00000000 : SMTP Server set by user [arg1] to [arg2]:[arg3].

    A user configured the SMTP server

    May also be shown as 4000005600000000 or 0x4000005600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0086
    User Response
    Information only; no action is required.
  • 40000057-00000000 : Telnet [arg1] by user [arg2].

    The specified user has enabled or disabled Telnet.

    May also be shown as 4000005700000000 or 0x4000005700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0087
    User Response
    Information only; no action is required.
  • 40000058-00000000 : DNS servers set by user [arg1]: UseAdditionalServers=[arg2], PreferredDNStype=[arg3], IPv4Server1=[arg4], IPv4Server2=[arg5], IPv4Server3=[arg6], IPv6Server1=[arg7], IPv6Server2=[arg8], IPv6Server3=[arg9].

    The specified user has configured the DNS servers.

    May also be shown as 4000005800000000 or 0x4000005800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0088
    User Response
    Information only; no action is required.
  • 40000059-00000000 : LAN over USB [arg1] by user [arg2].

    A user configured USB-LAN

    May also be shown as 4000005900000000 or 0x4000005900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0089
    User Response
    Information only; no action is required.
  • 4000005a-00000000 : LAN over USB Port Forwarding set by user [arg1]: ExternalPort=[arg2], USB-LAN port=[arg3].

    A user configured USB-LAN port forwarding

    May also be shown as 4000005a00000000 or 0x4000005a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0090
    User Response
    Information only; no action is required.
  • 4000005b-00000000 : Secure Web services (HTTPS) [arg1] by user [arg2].

    A user enables or disables Secure web services

    May also be shown as 4000005b00000000 or 0x4000005b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0091
    User Response
    Information only; no action is required.
  • 4000005c-00000000 : Secure CIM/XML(HTTPS) [arg1] by user [arg2].

    The secure CIM-XML port has been enabled or disabled.

    May also be shown as 4000005c00000000 or 0x4000005c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0092
    User Response
    Information only; no action is required.
  • 4000005d-00000000 : Secure LDAP [arg1] by user [arg2].

    A user enables or disables Secure LDAP services

    May also be shown as 4000005d00000000 or 0x4000005d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0093
    User Response
    Information only; no action is required.
  • 4000005e-00000000 : SSH [arg1] by user [arg2].

    The specified user has enabled or disabled the Secure Shell (SSH) service.

    May also be shown as 4000005e00000000 or 0x4000005e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0094
    User Response
    Information only; no action is required.
  • 4000005f-00000000 : Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2], OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4], LoaderTimeout=[arg5].

    A user configures Server Timeouts

    May also be shown as 4000005f00000000 or 0x4000005f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0095
    User Response
    Information only; no action is required.
  • 40000060-00000000 : License key for [arg1] added by user [arg2].

    A Integrated Management Module license that allows access to the specified feature was added to the system.

    May also be shown as 4000006000000000 or 0x4000006000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0096
    User Response
    Information only; no action is required.
  • 40000061-00000000 : License key for [arg1] removed by user [arg2].

    The specified user has removed an Integrated Management Module license. Access to the specified feature is no longer allowed.

    May also be shown as 4000006100000000 or 0x4000006100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0097
    User Response
    Information only; no action is required.
  • 40000062-00000000 : Global Login General Settings set by user [arg1]: AuthenticationMethod=[arg2], LockoutPeriod=[arg3], SessionTimeout=[arg4].

    A user changes the Global Login General Settings

    May also be shown as 4000006200000000 or 0x4000006200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0098
    User Response
    Information only; no action is required.
  • 40000063-00000000 : Global Login Account Security set by user [arg1]: PasswordRequired=[arg2], PasswordExpirationPeriod=[arg3], MinimumPasswordReuseCycle=[arg4], MinimumPasswordLength=[arg5], MinimumPasswordChangeInterval=[arg6], MaxmumLoginFailures=[arg7], LockoutAfterMaxFailures=[arg8], MinimumDifferentCharacters=[arg9], DefaultIDExpired=[arg10], ChangePasswordFirstAccess=[arg11].

    A user changes the Global Login Account Security Settings to Legacy

    May also be shown as 4000006300000000 or 0x4000006300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0099
    User Response
    Information only; no action is required.
  • 40000064-00000000 : User [arg1] created.

    A user account has been created.

    May also be shown as 4000006400000000 or 0x4000006400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0100
    User Response
    Information only; no action is required.
  • 40000065-00000000 : User [arg1] removed.

    A user account has been removed.

    May also be shown as 4000006500000000 or 0x4000006500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0101
    User Response
    Information only; no action is required.
  • 40000066-00000000 : User [arg1] password modified.

    The password for the specified user account has been changed.

    May also be shown as 4000006600000000 or 0x4000006600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0102
    User Response
    Information only; no action is required.
  • 40000067-00000000 : User [arg1] role set to [arg2].

    A user account role assigned

    May also be shown as 4000006700000000 or 0x4000006700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0103
    User Response
    Information only; no action is required.
  • 40000068-00000000 : User [arg1] custom privileges set: [arg2].

    User account privileges assigned

    May also be shown as 4000006800000000 or 0x4000006800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0104
    User Response
    Information only; no action is required.
  • 40000069-00000000 : User [arg1] for SNMPv3 set: AuthenticationProtocol=[arg2], PrivacyProtocol=[arg3], AccessType=[arg4], HostforTraps=[arg5].

    User account SNMPv3 settings changed

    May also be shown as 4000006900000000 or 0x4000006900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0105
    User Response
    Information only; no action is required.
  • 4000006a-00000000 : SSH Client key added for user [arg1].

    User locally defined an SSH Client key

    May also be shown as 4000006a00000000 or 0x4000006a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0106
    User Response
    Information only; no action is required.
  • 4000006b-00000000 : SSH Client key imported for user [arg1] from [arg2].

    User imported an SSH Client key

    May also be shown as 4000006b00000000 or 0x4000006b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0107
    User Response
    Information only; no action is required.
  • 4000006c-00000000 : SSH Client key removed from user [arg1].

    User removed an SSH Client key

    May also be shown as 4000006c00000000 or 0x4000006c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0108
    User Response
    Information only; no action is required.
  • 4000006d-00000000 : Management Controller [arg1]: Configuration saved to a file by user [arg2].

    A user saves a Management Controller configuration to a file.

    May also be shown as 4000006d00000000 or 0x4000006d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0109
    User Response
    Information only; no action is required.
  • 4000006e-00000000 : Alert Configuration Global Event Notification set by user [arg1]: RetryLimit=[arg2], RetryInterval=[arg3], EntryInterval=[arg4].

    A user changes the Global Event Notification settings.

    May also be shown as 4000006e00000000 or 0x4000006e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0110
    User Response
    Information only; no action is required.
  • 4000006f-00000000 : Alert Recipient Number [arg1] updated: Name=[arg2], DeliveryMethod=[arg3], Address=[arg4], IncludeLog=[arg5], Enabled=[arg6], EnabledAlerts=[arg7], AllowedFilters=[arg8].

    The specified user has changed or reset the remote alert recipient configuration.

    May also be shown as 4000006f00000000 or 0x4000006f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0111
    User Response
    Information only; no action is required.
  • 40000070-00000000 : SNMP Traps enabled by user [arg1]: EnabledAlerts=[arg2], AllowedFilters=[arg3] .

    The specified user has enabled Simple Network Management Protocol (SNMP) traps.

    May also be shown as 4000007000000000 or 0x4000007000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0112
    User Response
    Information only; no action is required.
  • 40000071-00000000 : The power cap value changed from [arg1] watts to [arg2] watts by user [arg3].

    The power capping level has been changed.

    May also be shown as 4000007100000000 or 0x4000007100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0113
    User Response
    Information only; no action is required
  • 40000072-00000000 : The minimum power cap value changed from [arg1] watts to [arg2] watts.

    The minimum power cap value has been changed.

    May also be shown as 4000007200000000 or 0x4000007200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0114
    User Response
    Information only; no action is required.
  • 40000073-00000000 : The maximum power cap value changed from [arg1] watts to [arg2] watts.

    The maximum power cap value has been changed.

    May also be shown as 4000007300000000 or 0x4000007300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0115
    User Response
    Information only; no action is required.
  • 40000074-00000000 : The soft minimum power cap value changed from [arg1] watts to [arg2] watts.

    The soft minimum power cap value has been changed.

    May also be shown as 4000007400000000 or 0x4000007400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0116
    User Response
    Information only; no action is required.
  • 40000075-00000000 : The measured power value exceeded the power cap value.

    The measured power value has exceeded the power cap value.

    May also be shown as 4000007500000000 or 0x4000007500000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Power
    SNMP Trap ID
    164
    CIM Information
    Prefix: IMM ID: 0117
    User Response
    • Make sure IMM firmware is at the latest level.
    • Raise the system power cap value or adjust the system workload to be less than the currently applied power cap.
  • 40000076-00000000 : The new minimum power cap value exceeded the power cap value.

    Minimum Power Cap exceeds Power Cap

    May also be shown as 4000007600000000 or 0x4000007600000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Power
    SNMP Trap ID
    164
    CIM Information
    Prefix: IMM ID: 0118
    User Response
    User may need to adjust the power cap value to be greater or equal to the minimum power cap.
  • 40000077-00000000 : Power capping was activated by user [arg1].

    The power capping control has been enabled.

    May also be shown as 4000007700000000 or 0x4000007700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0119
    User Response
    Information only; no action is required.
  • 40000078-00000000 : Power capping was deactivated by user [arg1].

    The power capping control has been enabled.

    May also be shown as 4000007800000000 or 0x4000007800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0120
    User Response
    Information only; no action is required.
  • 40000079-00000000 : Static Power Savings mode has been turned on by user [arg1].

    Static Power Savings mode turned on by user

    May also be shown as 4000007900000000 or 0x4000007900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0121
    User Response
    Information only; no action is required.
  • 4000007a-00000000 : Static Power Savings mode has been turned off by user [arg1].

    Static Power Savings mode turned off by user

    May also be shown as 4000007a00000000 or 0x4000007a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0122
    User Response
    Information only; no action is required.
  • 4000007b-00000000 : Dynamic Power Savings mode has been turned on by user [arg1].

    Dynamic Power Savings mode turned on by user

    May also be shown as 4000007b00000000 or 0x4000007b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0123
    User Response
    Information only; no action is required.
  • 4000007c-00000000 : Dynamic Power Savings mode has been turned off by user [arg1].

    Dynamic Power Savings mode turned off by user

    May also be shown as 4000007c00000000 or 0x4000007c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0124
    User Response
    Information only; no action is required.
  • 4000007d-00000000 : Power cap and external throttling occurred.

    Power cap and external throttling has occurred.

    May also be shown as 4000007d00000000 or 0x4000007d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0125
    User Response
    Information only; no action is required.
  • 4000007e-00000000 : External throttling occurred .

    External throttling has occurred.

    May also be shown as 4000007e00000000 or 0x4000007e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0126
    User Response
    Information only; no action is required.
  • 4000007f-00000000 : Power cap throttling occurred.

    Power cap throttling has occurrred.

    May also be shown as 4000007f00000000 or 0x4000007f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0127
    User Response
    Information only; no action is required.
  • 40000080-00000000 : Remote Control session started by user [arg1] in [arg2] mode.

    Remote Control session started

    May also be shown as 4000008000000000 or 0x4000008000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0128
    User Response
    Information only; no action is required.
  • 40000081-00000000 : PXE boot requested by user [arg1].

    PXE boot requested

    May also be shown as 4000008100000000 or 0x4000008100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0129
    User Response
    Information only; no action is required.
  • 40000082-00000000 : The measured power value has returned below the power cap value.

    The measured power value has returned below the power cap value.

    May also be shown as 4000008200000000 or 0x4000008200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Power
    SNMP Trap ID
    164
    CIM Information
    Prefix: IMM ID: 0130
    User Response
    Information only; no action is required.
  • 40000083-00000000 : The new minimum power cap value has returned below the power cap value.

    The new minimum power cap value has returned below the power cap value.

    May also be shown as 4000008300000000 or 0x4000008300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Power
    SNMP Trap ID
    164
    CIM Information
    Prefix: IMM ID: 0131
    User Response
    Information only; no action is required.
  • 40000084-00000000 : IMM firmware mismatch between nodes [arg1] and [arg2]. Please attempt to flash the IMM firmware to the same level on all nodes.

    A mismatch of IMM firmware between nodes has been detected.

    May also be shown as 4000008400000000 or 0x4000008400000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0132
    User Response
    Attempt to flash the IMM firmware to the same level on all nodes.
  • 40000085-00000000 : FPGA firmware mismatch between nodes [arg1] and [arg2]. Please attempt to flash the FPGA firmware to the same level on all nodes.

    A mismatch of FPGA firmware between nodes has been detected.

    May also be shown as 4000008500000000 or 0x4000008500000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0133
    User Response
    Attempt to flash the FPGA firmware to the same level on all nodes.
  • 40000086-00000000 : Test Call Home Generated by user [arg1].

    The specified user has generated a test automatic support notification.

    May also be shown as 4000008600000000 or 0x4000008600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    Yes
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0134
    User Response
    Information only; no action is required.
  • 40000087-00000000 : Manual Call Home by user [arg1]: [arg2].

    The specified user has submitted a service request.

    May also be shown as 4000008700000000 or 0x4000008700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    Yes
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0135
    User Response
    IBM Support will address the problem.
  • 40000088-00000000 : Management Controller [arg1]: Configuration restoration from a file by user [arg2] completed.

    The specified user has successfully restored the configuration of the specified management controller from a file.

    May also be shown as 4000008800000000 or 0x4000008800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0136
    User Response
    Information only; no action is required.
  • 40000089-00000000 : Management Controller [arg1]: Configuration restoration from a file by user [arg2] failed to complete.

    Restoration of the configuration of the specified management controller from a file by the specified user has not been completed.

    May also be shown as 4000008900000000 or 0x4000008900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0137
    User Response
    1. Turn off the server and disconnect it from the power source. You must disconnect the server from ac power to reset the IMM.
    2. After 45 seconds, reconnect the server to the power source and turn on the server.
    3. Retry the operation
  • 4000008a-00000000 : Management Controller [arg1]: Configuration restoration from a file by user [arg2] failed to start.

    Restoration of the configuration of the specified management controller from a file by the specified user has failed to start.

    May also be shown as 4000008a00000000 or 0x4000008a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0138
    User Response
    1. Turn off the server and disconnect it from the power source. You must disconnect the server from ac power to reset the IMM.
    2. After 45 seconds, reconnect the server to the power source and turn on the server.
    3. Retry the operation
  • 4000008b-00000000 : One or more of the Storage Management IP addresses has changed.

    This message is for the use case where an IP address for the Storage Management has changed

    May also be shown as 4000008b00000000 or 0x4000008b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - IMM Network event
    SNMP Trap ID
    37
    CIM Information
    Prefix: IMM ID: 0139
    User Response
    Information only; no action is required.
  • 4000008c-00000000 : Security: Userid: [arg1] had [arg2] login failures from a CIM client at IP address [arg3].

    This message is for the use case where a user has failed to log in to a Management Controller from CIM.

    May also be shown as 4000008c00000000 or 0x4000008c00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0140
    User Response
    :
  • 4000008d-00000000 : Remote access attempt failed. Invalid userid or password received. Userid is [arg1] from a CIM client at IP address [arg2].

    This message is for the use case where a remote user has failed to establish a remote control session from CIM.

    May also be shown as 4000008d00000000 or 0x4000008d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0141
    User Response
    :
  • 4000009d-00000000 : Login ID: [arg1] from [arg2] at IP address [arg3] has logged off.

    A user logged off of a Management Controller.

    May also be shown as 4000009d00000000 or 0x4000009d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0157
    User Response
    Information only; no action is required.
  • 400000a7-00000000 : The server is restarted by chassis control command.

    Server was restarted by chassis control command

    May also be shown as 400000a700000000 or 0x400000a700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0167
    User Response
    Information only; no action is required.
  • 400000a9-00000000 : The server is powered-up via power pushbutton.

    Server is powered-up via power pushbutton

    May also be shown as 400000a900000000 or 0x400000a900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0169
    User Response
    Information only; no action is required.
  • 80010002-2801ffff : Numeric sensor [NumericSensorElementName] going low (lower non-critical) has asserted.

    The CMOS battery voltage has dropped below its specified threshold.

    May also be shown as 800100022801ffff or 0x800100022801ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Voltage
    SNMP Trap ID
    13
    CIM Information
    Prefix: PLAT ID: 0476
    User Response
    Replace the CMOS battery.
  • 80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

    A Voltage has dropped below its specified threshold (sensor SysBrd 12V, SysBrd 3.3V, or SysBrd 5V).

    May also be shown as 800102020701ffff or 0x800102020701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    • (Trained service technician only) If the specified sensor is SysBrd 3.3V or SysBrd 5V, replace the system board.
    • If the specified sensor is SysBrd 12V, check the IMM event log for power-supply-related issues, and resolve those issues. If the problem remains, (trained service technician only) replace the system board.
  • 80010202-2801ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

    The CMOS battery voltage has dropped below its specified threshold.

    May also be shown as 800102022801ffff or 0x800102022801ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    Replace the CMOS battery.
  • 80010204-1d01ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

    IMM has detected the speed of Fan 1 (Fan 1A Tach or Fan 1B Tach) has gone low.

    May also be shown as 800102041d01ffff or 0x800102041d01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    • Reseat the failing fan indicated by the lit LED on the fan.
    • Replace Fan.
  • 80010204-1d02ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

    IMM has detected the speed of Fan 2 (Fan 2A Tach or Fan 2B Tach) has gone low.

    May also be shown as 800102041d02ffff or 0x800102041d02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    • Reseat the failing fan indicated by the lit LED on the fan.
    • Replace Fan.
  • 80010204-1d03ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

    IMM has detected the speed of Fan 3 (Fan 3A Tach or Fan 3B Tach) has gone low.

    May also be shown as 800102041d03ffff or 0x800102041d03ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    • Reseat the failing fan indicated by the lit LED on the fan.
    • Replace Fan.
  • 80010204-1d04ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

    IMM has detected the speed of Fan 4 (Fan 4A Tach or Fan 4B Tach) has gone low.

    May also be shown as 800102041d04ffff or 0x800102041d04ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    • Reseat the failing fan indicated by the lit LED on the fan.
    • Replace Fan.
  • 80010204-1d05ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

    IMM has detected the speed of Fan 5 (Fan 5A Tach or Fan 5B Tach) has gone low.

    May also be shown as 800102041d05ffff or 0x800102041d05ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    • Reseat the failing fan indicated by the lit LED on the fan.
    • Replace Fan.
  • 80010204-1d06ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

    IMM has detected the speed of Fan 6 (Fan 6A Tach or Fan 6B Tach) has gone low.

    May also be shown as 800102041d06ffff or 0x800102041d06ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    • Reseat the failing fan indicated by the lit LED on the fan.
    • Replace Fan.
  • 80010701-1001ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    IMM has detected that the PCI riser temperature has risen above normal levels.

    May also be shown as 800107011001ffff or 0x800107011001ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010701-1401ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.

    May also be shown as 800107011401ffff or 0x800107011401ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010701-1402ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.

    May also be shown as 800107011402ffff or 0x800107011402ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010701-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.

    May also be shown as 800107011403ffff or 0x800107011403ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010701-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.

    May also be shown as 800107011404ffff or 0x800107011404ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010701-1405ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.

    May also be shown as 800107011405ffff or 0x800107011405ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010701-1406ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above normal levels.

    May also be shown as 800107011406ffff or 0x800107011406ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010701-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    IMM has detected that the ambient temperature has risen above normal.

    May also be shown as 800107012701ffff or 0x800107012701ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010701-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.

    The PCH temperature has risen above normal.

    May also be shown as 800107012d01ffff or 0x800107012d01ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010901-1401ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above the upper critical threshold.

    May also be shown as 800109011401ffff or 0x800109011401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010901-1402ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above the upper critical threshold.

    May also be shown as 800109011402ffff or 0x800109011402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010901-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above the upper critical threshold.

    May also be shown as 800109011403ffff or 0x800109011403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010901-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above the upper critical threshold.

    May also be shown as 800109011404ffff or 0x800109011404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010901-1405ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above the upper critical threshold.

    May also be shown as 800109011405ffff or 0x800109011405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010901-1406ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    IMM has detected that the temperature of a system board voltage regulator has risen above the upper critical threshold.

    May also be shown as 800109011406ffff or 0x800109011406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010901-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    IMM has detected that the ambient temperature has risen above its upper critical threshold.

    May also be shown as 800109012701ffff or 0x800109012701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Check event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010901-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    The PCH temperature sensor has risen above its upper critical threshold. A soft shutdown will be attempted.

    May also be shown as 800109012d01ffff or 0x800109012d01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Check IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010902-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

    A voltage has risen above its specified threshold (sensor SysBrd 12V, SysBrd 3.3V, or SysBrd 5V).

    May also be shown as 800109020701ffff or 0x800109020701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    • (Trained service technician only) If the specified sensor is SysBrd 3.3V or SysBrd 5V, replace the system board.
    • If the specified sensor is SysBrd 12V, check the IMM Web event log for power-supply-related issues, and resolve those issues.: If the problem remains, (trained service technician only) replace the system board.
  • 80010b01-1401ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

    The temperature for a system board voltage regulator has risen above its threshold. A hard shutdown has occurred.

    May also be shown as 80010b011401ffff or 0x80010b011401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010b01-1402ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

    The temperature for a system board voltage regulator has risen above its threshold. A hard shutdown has occurred. asserted.

    May also be shown as 80010b011402ffff or 0x80010b011402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010b01-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

    The temperature for a system board voltage regulator has risen above its threshold. A hard shutdown has occurred.

    May also be shown as 80010b011403ffff or 0x80010b011403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010b01-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

    The temperature for a system board voltage regulator has risen above its threshold. A hard shutdown has occurred.

    May also be shown as 80010b011404ffff or 0x80010b011404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010b01-1405ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

    The temperature for a system board voltage regulator has risen above its threshold. A hard shutdown has occurred.

    May also be shown as 80010b011405ffff or 0x80010b011405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010b01-1406ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

    The temperature for a system board voltage regulator has risen above its threshold. A hard shutdown has occurred.

    May also be shown as 80010b011406ffff or 0x80010b011406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010b01-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

    The ambient temperature has risen above its threshold. A hard shutdown has occurred.

    May also be shown as 80010b012701ffff or 0x80010b012701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Check event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80010b01-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

    The PCH temperature sensor has risen above its threshold. A hard shutdown has occurred.

    May also be shown as 80010b012d01ffff or 0x80010b012d01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. If this is the only temperature related event and the event persists, replace the system board (Trained Service personnel only).
  • 80030006-2101ffff : Sensor [SensorElementName] has deasserted.

    Secure UEFI update completed Successfully.

    May also be shown as 800300062101ffff or 0x800300062101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    Information only; no action is required.
  • 80030108-0a01ffff : Sensor [SensorElementName] has asserted.

    Power Supply load has reached maximum capacity.

    May also be shown as 800301080a01ffff or 0x800301080a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    PS Heavy Load: The system will throttle to lower the load. Information only; no action is required.
  • 8003010e-2581ffff : Sensor [SensorElementName] has asserted.

    IMM has detected that the memory size has changed.

    May also be shown as 8003010e2581ffff or 0x8003010e2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 80030112-0601ffff : Sensor [SensorElementName] has asserted.

    This message is for the use case when system firmware entered maintenance mode

    May also be shown as 800301120601ffff or 0x800301120601ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    System firmware will enter system maintenance mode if firmware flash is in progress. Information only, no User Action is required.
  • 80070101-0b09ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state.

    IMM has detected that the temperature for ML2 Card has transitioned to a non critical state.

    May also be shown as 800701010b09ffff or 0x800701010b09ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0520
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. (Trained service technician only) Replace ML2 Card.
  • 8007010f-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state.

    IMM has detected that disk GPT (GUID Partition Table) corruption or security boot error.

    May also be shown as 8007010f2201ffff or 0x8007010f2201ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • 80070114-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state.

    Trusted Platform Module (TPM) event has transitioned to non critical state.

    May also be shown as 800701142201ffff or 0x800701142201ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 80070201-0301ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 1 temperature Sensor has transitioned to critical.

    May also be shown as 800702010301ffff or 0x800702010301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80070201-0302ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 2 temperature Sensor has transitioned to critical.

    May also be shown as 800702010302ffff or 0x800702010302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80070201-0303ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 3 temperature Sensor has transitioned to critical.

    May also be shown as 800702010303ffff or 0x800702010303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80070201-0304ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 4 temperature Sensor has transitioned to critical.

    May also be shown as 800702010304ffff or 0x800702010304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
  • 80070202-0701ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    The Sys Board Fault sensor has detected a problem with the system board.

    May also be shown as 800702020701ffff or 0x800702020701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0522
    User Response

    Complete the following steps:

    1. Remove any recently installed components.
    2. Try to power on the node.
      • If the node successfully powers on, complete the following steps:
        1. Check the ServerProven website to make sure that recently installed components are compatible with the compute node.
        2. Inspect the previously installed components for physical damage.
      • If the node does not successfully power on or if this is not the first occurrence of this problem, (trained service technician only) replace the system board.
  • 80070204-2584ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a Power Supply Fan (PS Fan Fault) has transitioned to critical.

    May also be shown as 800702042584ffff or 0x800702042584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check for Power Supply with PS fault in the event log
    2. Replace the Power Supply that has the PS Fault
  • 80070208-2584ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a Power Supply Sensor has transitioned to critical. (PS CSF Fault or PS Therm Fault)

    May also be shown as 800702082584ffff or 0x800702082584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check for Power Supply with PS fault in the IMM event log
    2. Replace the Power Supply that has the PS Fault
  • 8007020f-2201ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a "Drive Key Fault" Sensor has transitioned to critical.

    May also be shown as 8007020f2201ffff or 0x8007020f2201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 8007020f-2582ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a "No I/O Resources" Sensor has transitioned to critical.

    May also be shown as 8007020f2582ffff or 0x8007020f2582ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 80070219-0701ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a System Board Fault Sensor has transitioned to critical.

    May also be shown as 800702190701ffff or 0x800702190701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 8007021b-0301ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 1 QPI Link Error.

    May also be shown as 8007021b0301ffff or 0x8007021b0301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 8007021b-0302ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 2 QPI Link Error.

    May also be shown as 8007021b0302ffff or 0x8007021b0302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 8007021b-0303ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 3 QPI Link Error.

    May also be shown as 8007021b0303ffff or 0x8007021b0303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 8007021b-0304ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 4 QPI Link Error.

    May also be shown as 8007021b0304ffff or 0x8007021b0304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 80070221-0b09ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a ML2 card internal error.

    May also be shown as 800702210b09ffff or 0x800702210b09ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check the IMM event log for any cooling issues for ML2 card.
    2. (Trained service technician only) Replace ML2 card.
  • 80070221-1f01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 1 QPI Link Error.

    May also be shown as 800702211f01ffff or 0x800702211f01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 80070221-1f02ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 2 QPI Link Error.

    May also be shown as 800702211f02ffff or 0x800702211f02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 80070221-1f03ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 3 QPI Link Error.

    May also be shown as 800702211f03ffff or 0x800702211f03ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 80070221-1f04ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.

    IMM has detected a CPU 4 QPI Link Error.

    May also be shown as 800702211f04ffff or 0x800702211f04ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 80070301-0301ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

    IMM has detected that the temperature for CPU 1 has transitioned to a non recoverable state.

    May also be shown as 800703010301ffff or 0x800703010301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. Make sure that the microprocessor 1 heat sink is securely installed.
    6. (Trained service technician only) Make sure that the microprocessor 1 heat sink is installed correctly and the thermal material is correctly applied.
    7. (Trained service technician only) Replace microprocessor 1.
  • 80070301-0302ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

    IMM has detected that the temperature for CPU 2 has transitioned to a non recoverable state.

    May also be shown as 800703010302ffff or 0x800703010302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. Make sure that the microprocessor 2 heat sink is securely installed.
    6. (Trained service technician only) Make sure that the microprocessor 2 heat sink is installed correctly and the thermal material is correctly applied.
    7. (Trained service technician only) Replace microprocessor 2.
  • 80070301-0303ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

    IMM has detected that the temperature for CPU 3 has transitioned to a non recoverable state.

    May also be shown as 800703010303ffff or 0x800703010303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. Make sure that the microprocessor 3 heat sink is securely installed.
    6. (Trained service technician only) Make sure that the microprocessor 3 heat sink is installed correctly and the thermal material is correctly applied.
    7. (Trained service technician only) Replace microprocessor 3.
  • 80070301-0304ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

    IMM has detected that the temperature for CPU 4 has transitioned to a non recoverable state.

    May also be shown as 800703010304ffff or 0x800703010304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. Make sure that the microprocessor 4 heat sink is securely installed.
    6. (Trained service technician only) Make sure that the microprocessor 4 heat sink is installed correctly and the thermal material is correctly applied.
    7. (Trained service technician only) Replace microprocessor 4.
  • 80070301-0b09ffff : IMM has detected that the temperature for ML2 card has transitioned to a non recoverable state.

    IMM has detected that the temperature for ML2 Card has transitioned to a non recoverable state.

    May also be shown as 800703010b09ffff or 0x800703010b09ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. (Trained service technician only) Replace ML2 Card.
  • 80070319-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state.

    IMM has detected system failed to resume from S3 power state.

    May also be shown as 800703192201ffff or 0x800703192201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
  • 80070603-0701ffff : Sensor [SensorElementName] has transitioned to non-recoverable.

    IMM has detected Voltage Regulator Error.

    May also be shown as 800706030701ffff or 0x800706030701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    • CPU 1 VRD: Indicates a problem with either the voltage regulator for CPU1 or CPU 1 itself
    • CPU 2 VRD: Indicates a problem with either the voltage regulator for CPU2 or CPU 2 itself
    • DIMM 01-06 VRD: Indicates a problem with either the voltage regulator for DIMMs 1-6 or 1 or more of the following components: DIMM1-DIMM6
    • DIMM 07-12 VRD: Indicates a problem with either the voltage regulator for DIMMs 7-12 or 1 or more of the following components: DIMM7-DIMM12
    • DIMM 13-18 VRD: Indicates a problem with either the voltage regulator for DIMMs 13-18 or 1 or more of the following components: DIMM13-DIMM18
    • DIMM 19-24 VRD: Indicates a problem with either the voltage regulator for DIMMs 19-24 or 1 or more of the following components: DIMM19-DIMM24
    • MainBrd ENET VRD: Indicates a problem with either the voltage regulator for the onboard Ethernet or ML2 card
    • MainBrd SAS VRD: Indicates a problem with either the voltage regulator for the onboard SAS or the RAID cache card
    • MainBrd VRD: Indicates a problem with a voltage regulator for the system board
    • System VRD: Indicates a problem with either a voltage regulator for the system board or the microprocessor and memory expansion tray
    1. Check the IMM Web event log. This event may be a symptom of an earlier error.
    2. Depending on the error perform the following steps.

    For a CPU 1 VRD or CPU 2 VRD error:

    1. Replace system board.
    2. Replace affected microprocessor.

    For a DIMM 01-06 VRD, DIMM 07-12 VRD, DIMM 13-18 VRD, or DIMM 19-24 VRD error:

    1. Replace DIMM(s) associated with error.
    2. Replace system board.

    For a MainBrd ENET VRD error:

    1. Replace the ML2 Ethernet Adapter if installed.
    2. Replace system board.

    For a MainBrd SAS VRD error:

    1. Replace the RAID cache card if installed.
    2. Replace system board.

    For a MainBrd VRD error:

    1. Replace system board.

    For a System VRD error:

    1. Replace microprocessor and memory expansion tray if installed.
    2. Replace system board.
  • 80070603-0b01ffff : Sensor [SensorElementName] has transitioned to non-recoverable.

    IMM has detected Voltage Regulator Error.

    May also be shown as 800706030b01ffff or 0x800706030b01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0530
    User Response

    ML2 card VRD: Indicates a problem with either the voltage regulator for the ML2 card or the ML2 card itself

    1. Check the IMM Web event log. This event may be a symptom of an earlier error.
    2. Replace the ML2 Ethernet Adapter if installed.
    3. Replace the system board.
  • 80070603-2584ffff : Sensor [SensorElementName] has transitioned to non-recoverable.

    IMM has detected Voltage Regulator Error.

    May also be shown as 800706032584ffff or 0x800706032584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0530
    User Response

    Power Supply: Indicates a problem with either the system board voltage or the power supply is failing

    1. Check the IMM Web event log. This event may be a symptom of an earlier error.
    2. Replace any newly installed options.
    3. Replace the power supplies.
    4. Replace the power interposer card if installed.
    5. Replace the system board.
  • 80070603-2b01ffff : Sensor [SensorElementName] has transitioned to non-recoverable.

    IMM has detected a voltage regulator error on the microprocessor and memory expansion tray.

    May also be shown as 800706032b01ffff or 0x800706032b01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    • CPU 3 VRD: Indicates a problem with either the voltage regulator for CPU3 or CPU 3 itself
    • CPU 4 VRD: Indicates a problem with either the voltage regulator for CPU4 or CPU 4 itself
    • DIMM 25-30 VRD: Indicates a problem with either the voltage regulator for DIMMs 25-30 or 1 or more of the following components: DIMM25-DIMM30
    • DIMM 31-36 VRD: Indicates a problem with either the voltage regulator for DIMMs 31-36 or 1 or more of the following components: DIMM31-DIMM36
    • DIMM 37-42 VRD: Indicates a problem with either the voltage regulator for DIMMs 37-42 or 1 or more of the following components: DIMM37-DIMM42
    • DIMM 43-48 VRD: Indicates a problem with either the voltage regulator for DIMMs 43-48 or 1 or more of the following components: DIMM43-DIMM48
    1. Check the IMM Web event log. This event may be a symptom of an earlier error.
    2. Depending on the error perform the following steps.

    For a CPU 3 VRD or CPU 4 VRD error:

    1. Replace the microprocessor and memory expansion tray.
    2. Replace affected microprocessor.

    For a DIMM 25-30 VRD, DIMM 31-36 VRD, DIMM 37-42 VRD, or DIMM 43-48 VRD error:

    1. Replace DIMM(s) associated with error.
    2. Replace the microprocessor and memory expansion tray.
  • 80070608-2584ffff : Sensor [SensorElementName] has transitioned to non-recoverable.

    IMM has detected Power Supply related fault. (PS 12V OC Fault, PS 12V OV Fault, PS 12V UV Fault, or PS AUX UV Fault)

    May also be shown as 800706082584ffff or 0x800706082584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    1. Check the power supply LEDs, see "Power-supply LEDs".
    2. Replace the failing power supply.
  • 8007060f-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable.

    Trusted Platform Module (TPM) initialization error.

    May also be shown as 8007060f2201ffff or 0x8007060f2201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 8008000f-2101ffff : Device [LogicalDeviceElementName] has been removed from unit [PhysicalPackageElementName].

    IMM has detected that the TPM Physical Presence switch has been deasserted.

    May also be shown as 8008000f2101ffff or 0x8008000f2101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0537
    User Response
    Information only; no action is required.
  • 80080128-2101ffff : Device [LogicalDeviceElementName] has been added.

    IMM has detected low security jumper has been added.

    May also be shown as 800801282101ffff or 0x800801282101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0536
    User Response
    Information only; no action is required.
  • 800b0108-1381ffff : Redundancy Lost for [RedundancySetElementName] has asserted.

    Power Supply Redundancy has been lost.

    May also be shown as 800b01081381ffff or 0x800b01081381ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Redundant Power Supply
    SNMP Trap ID
    9
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    1. Power Unit: Check if Power Supply is missing, unplugged.
    2. Check the power supply LEDs, see "Power-supply LEDs"
    3. Replace the affected power supply.
  • 800b010a-1e81ffff : Redundancy Lost for [RedundancySetElementName] has asserted.

    Fan Redundancy has been lost.

    May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    Replace Fan 1
  • 800b010a-1e82ffff : Redundancy Lost for [RedundancySetElementName] has asserted.

    Fan Redundancy has been lost.

    May also be shown as 800b010a1e82ffff or 0x800b010a1e82ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    Replace Fan 2
  • 800b010a-1e83ffff : Redundancy Lost for [RedundancySetElementName] has asserted.

    Fan Redundancy has been lost.

    May also be shown as 800b010a1e83ffff or 0x800b010a1e83ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    Replace Fan 3
  • 800b010a-1e84ffff : Redundancy Lost for [RedundancySetElementName] has asserted.

    Fan Redundancy has been lost.

    May also be shown as 800b010a1e84ffff or 0x800b010a1e84ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    Replace Fan 4
  • 800b010a-1e85ffff : Redundancy Lost for [RedundancySetElementName] has asserted.

    Fan Redundancy has been lost.

    May also be shown as 800b010a1e85ffff or 0x800b010a1e85ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    Replace Fan 5
  • 800b010a-1e86ffff : Redundancy Lost for [RedundancySetElementName] has asserted.

    Fan Redundancy has been lost.

    May also be shown as 800b010a1e86ffff or 0x800b010a1e86ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    Replace Fan 6
  • 800b010c-2581ffff : Redundancy Lost for [RedundancySetElementName] has asserted.

    Backup Memory Redundancy has been lost.

    May also be shown as 800b010c2581ffff or 0x800b010c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 800b0208-1381ffff : Redundancy Degraded for [RedundancySetElementName] has asserted.

    Power unit is no longer in the redundant state.

    May also be shown as 800b02081381ffff or 0x800b02081381ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Redundant Power Supply
    SNMP Trap ID
    10
    CIM Information
    Prefix: PLAT ID: 0804
    User Response
    1. Check if Power Supply is missing, unplugged.
    2. Check the power supply LEDs, see "Power-supply LEDs"
    3. Replace the affected power supply.
  • 800b0308-1381ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.

    Power Supply is supplying sufficient power but is no longer in a redundancy state.

    May also be shown as 800b03081381ffff or 0x800b03081381ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Redundant Power Supply
    SNMP Trap ID
    10
    CIM Information
    Prefix: PLAT ID: 0806
    User Response
    1. Power Unit: Check if Power Supply is missing, unplugged.
    2. Check the power supply LEDs, see "Power-supply LEDs"
    3. Replace the affected power supply.
  • 800b0309-0a01ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.

    Power Supply is supplying sufficient power but is no longer in a redundancy state.

    May also be shown as 800b03090a01ffff or 0x800b03090a01ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Redundant Power Supply
    SNMP Trap ID
    10
    CIM Information
    Prefix: PLAT ID: 0806
    User Response
    1. Power Unit: Check if Power Supply is missing, unplugged.
    2. Check the power supply LEDs, see "Power-supply LEDs"
    3. Replace the affected power supply.
  • 800b030c-2581ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.

    Backup Memory has transitioned from Redundancy Degraded or Fully Redundant to Non-redundant:Sufficient.

    May also be shown as 800b030c2581ffff or 0x800b030c2581ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0806
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 800b0508-1381ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    Lost redundancy insufficient power for Power Unit

    May also be shown as 800b05081381ffff or 0x800b05081381ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Redundant Power Supply
    SNMP Trap ID
    9
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    1. Power Unit: Check if Power Supply is missing, unplugged.
    2. Check the power supply LEDs, see "Power-supply LEDs"
    3. Replace the affected power supply.
  • 800b0509-0a01ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient Resources for Power supply.

    May also be shown as 800b05090a01ffff or 0x800b05090a01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Redundant Power Supply
    SNMP Trap ID
    9
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    1. Power Unit: Check if Power Supply is missing, unplugged.
    2. Check the power supply LEDs, see "Power-supply LEDs"
    3. Replace the affected power supply.
    4. Check the power supply max rate and power capping policy, if the required power resource is not met, change the power supply or modify power capping mechanism.
  • 800b050a-1e81ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    Insufficient cooling provided by fan 1.

    May also be shown as 800b050a1e81ffff or 0x800b050a1e81ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    Replace Fan 1
  • 800b050a-1e82ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    Insufficient cooling provided by fan 2.

    May also be shown as 800b050a1e82ffff or 0x800b050a1e82ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    Replace Fan2
  • 800b050a-1e83ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    Insufficient cooling provided by fan 3.

    May also be shown as 800b050a1e83ffff or 0x800b050a1e83ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    Replace Fan 3
  • 800b050a-1e84ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    Insufficient cooling provided by fan 4.

    May also be shown as 800b050a1e84ffff or 0x800b050a1e84ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    Replace Fan 4
  • 800b050a-1e85ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    Insufficient cooling provided by fan 5.

    May also be shown as 800b050a1e85ffff or 0x800b050a1e85ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    Replace Fan 5
  • 800b050a-1e86ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    Insufficient cooling provided by fan 6.

    May also be shown as 800b050a1e86ffff or 0x800b050a1e86ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    Replace Fan 6
  • 800b050c-2581ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

    Backup Memory Sensor has transitioned to Non-redundant:Insufficient Resources.

    May also be shown as 800b050c2581ffff or 0x800b050c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0007-0301ffff : [ProcessorElementName] has Failed with IERR.

    IMM has detected processor 1 failed - IERR condition.

    May also be shown as 806f00070301ffff or 0x806f00070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0042
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0007-0302ffff : [ProcessorElementName] has Failed with IERR.

    IMM has detected processor 2 failed - IERR condition.

    May also be shown as 806f00070302ffff or 0x806f00070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0042
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0007-0303ffff : [ProcessorElementName] has Failed with IERR.

    IMM has detected processor 3 failed - IERR condition.

    May also be shown as 806f00070303ffff or 0x806f00070303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0042
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0007-0304ffff : [ProcessorElementName] has Failed with IERR.

    IMM has detected processor 4 failed - IERR condition.

    May also be shown as 806f00070304ffff or 0x806f00070304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0042
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0008-0a01ffff : [PowerSupplyElementName] has been added to container [PhysicalPackageElementName].

    IMM has detected a Power Supply has been added.

    May also be shown as 806f00080a01ffff or 0x806f00080a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0084
    User Response
    Power Supply 1: Information only; no action is required.
  • 806f0008-0a02ffff : [PowerSupplyElementName] has been added to container [PhysicalPackageElementName].

    IMM has detected a Power Supply has been added.

    May also be shown as 806f00080a02ffff or 0x806f00080a02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0084
    User Response
    Power Supply 2: Information only; no action is required.
  • 806f0009-1381ffff : [PowerSupplyElementName] has been turned off.

    IMM has detected that the system power has been turned off.

    May also be shown as 806f00091381ffff or 0x806f00091381ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Power Off
    SNMP Trap ID
    23
    CIM Information
    Prefix: PLAT ID: 0106
    User Response
    Host Power: Information only; no action is required.
  • 806f000d-0400ffff : The [StorageVolumeElementName] has been added.

    Hard drive 0 has been installed.

    May also be shown as 806f000d0400ffff or 0x806f000d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0401ffff : The [StorageVolumeElementName] has been added.

    Hard drive 1 has been installed.

    May also be shown as 806f000d0401ffff or 0x806f000d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0402ffff : The [StorageVolumeElementName] has been added.

    Hard drive 2 has been installed.

    May also be shown as 806f000d0402ffff or 0x806f000d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0403ffff : The [StorageVolumeElementName] has been added.

    Hard drive 3 has been installed.

    May also be shown as 806f000d0403ffff or 0x806f000d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0404ffff : The [StorageVolumeElementName] has been added.

    Hard drive 4 has been installed.

    May also be shown as 806f000d0404ffff or 0x806f000d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0405ffff : The [StorageVolumeElementName] has been added.

    Hard drive 5 has been installed.

    May also be shown as 806f000d0405ffff or 0x806f000d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0406ffff : The [StorageVolumeElementName] has been added.

    Hard drive 6 has been installed.

    May also be shown as 806f000d0406ffff or 0x806f000d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0407ffff : The [StorageVolumeElementName] has been added.

    Hard drive 7 has been installed.

    May also be shown as 806f000d0407ffff or 0x806f000d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0408ffff : The [StorageVolumeElementName] has been added.

    Hard drive 8 has been installed.

    May also be shown as 806f000d0408ffff or 0x806f000d0408ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0409ffff : The [StorageVolumeElementName] has been added.

    Hard drive 9 has been installed.

    May also be shown as 806f000d0409ffff or 0x806f000d0409ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-040affff : The [StorageVolumeElementName] has been added.

    Hard drive 10 has been installed.

    May also be shown as 806f000d040affff or 0x806f000d040affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-040bffff : The [StorageVolumeElementName] has been added.

    Hard drive 11 has been installed.

    May also be shown as 806f000d040bffff or 0x806f000d040bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-040cffff : The [StorageVolumeElementName] has been added.

    Hard drive 12 has been installed.

    May also be shown as 806f000d040cffff or 0x806f000d040cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-040dffff : The [StorageVolumeElementName] has been added.

    Hard drive 13 has been installed.

    May also be shown as 806f000d040dffff or 0x806f000d040dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-040effff : The [StorageVolumeElementName] has been added.

    Hard drive 14 has been installed.

    May also be shown as 806f000d040effff or 0x806f000d040effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-040fffff : The [StorageVolumeElementName] has been added.

    Hard drive 15 has been installed.

    May also be shown as 806f000d040fffff or 0x806f000d040fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0410ffff : The [StorageVolumeElementName] has been added.

    Hard drive 16 has been installed.

    May also be shown as 806f000d0410ffff or 0x806f000d0410ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0411ffff : The [StorageVolumeElementName] has been added.

    Hard drive 17 has been installed.

    May also be shown as 806f000d0411ffff or 0x806f000d0411ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0412ffff : The [StorageVolumeElementName] has been added.

    Hard drive 18 has been installed.

    May also be shown as 806f000d0412ffff or 0x806f000d0412ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0413ffff : The [StorageVolumeElementName] has been added.

    Hard drive 19 has been installed.

    May also be shown as 806f000d0413ffff or 0x806f000d0413ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0414ffff : The [StorageVolumeElementName] has been added.

    Hard drive 20 has been installed.

    May also be shown as 806f000d0414ffff or 0x806f000d0414ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0415ffff : The [StorageVolumeElementName] has been added.

    Hard drive 21 has been installed.

    May also be shown as 806f000d0415ffff or 0x806f000d0415ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0416ffff : The [StorageVolumeElementName] has been added.

    Hard drive 22 has been installed.

    May also be shown as 806f000d0416ffff or 0x806f000d0416ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0417ffff : The [StorageVolumeElementName] has been added.

    Hard drive 23 has been installed.

    May also be shown as 806f000d0417ffff or 0x806f000d0417ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0418ffff : The [StorageVolumeElementName] has been added.

    Hard drive 24 has been installed.

    May also be shown as 806f000d0418ffff or 0x806f000d0418ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-0419ffff : The [StorageVolumeElementName] has been added.

    Hard drive 25 has been installed.

    May also be shown as 806f000d0419ffff or 0x806f000d0419ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-041affff : The [StorageVolumeElementName] has been added.

    Hard drive 26 has been installed.

    May also be shown as 806f000d041affff or 0x806f000d041affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-041bffff : The [StorageVolumeElementName] has been added.

    Hard drive 27 has been installed.

    May also be shown as 806f000d041bffff or 0x806f000d041bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-041cffff : The [StorageVolumeElementName] has been added.

    Hard drive 28 has been installed.

    May also be shown as 806f000d041cffff or 0x806f000d041cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-041dffff : The [StorageVolumeElementName] has been added.

    Hard drive 29 has been installed.

    May also be shown as 806f000d041dffff or 0x806f000d041dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-041effff : The [StorageVolumeElementName] has been added.

    Hard drive 30 has been installed.

    May also be shown as 806f000d041effff or 0x806f000d041effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000d-041fffff : The [StorageVolumeElementName] has been added.

    Hard drive 31 has been installed.

    May also be shown as 806f000d041fffff or 0x806f000d041fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    Information only; no action is required.
  • 806f000f-220101ff : The System [ComputerSystemElementName] has detected no memory in the system.

    IMM has detected that there is no memory in the system.

    May also be shown as 806f000f220101ff or 0x806f000f220101ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0794
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220102ff : Subsystem [MemoryElementName] has insufficient memory for operation.

    IMM has detected that the usable Memory is insufficient for operation. (ABR Status, Firmware Error)

    May also be shown as 806f000f220102ff or 0x806f000f220102ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0132
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220103ff : The System [ComputerSystemElementName] encountered firmware error - unrecoverable boot device failure.

    IMM has detected that System Firmware Error Unrecoverable boot device failure has occurred. (ABR Status or Firmware Error)

    May also be shown as 806f000f220103ff or 0x806f000f220103ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0770
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220104ff : The System [ComputerSystemElementName]has encountered a motherboard failure.

    IMM has detected a fatal motherboard error in the system.

    May also be shown as 806f000f220104ff or 0x806f000f220104ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0795
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220107ff : The System [ComputerSystemElementName] encountered firmware error - unrecoverable keyboard failure.

    IMM has detected that System Firmware Error Unrecoverable Keyboard failure has occurred.

    May also be shown as 806f000f220107ff or 0x806f000f220107ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0764
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-22010aff : The System [ComputerSystemElementName] encountered firmware error - no video device detected.

    IMM has detected that System Firmware Error No video device detected has occurred.

    May also be shown as 806f000f22010aff or 0x806f000f22010aff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0766
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-22010bff : Firmware BIOS (ROM) corruption was detected on system [ComputerSystemElementName] during POST.

    Firmware BIOS (ROM) corruption was detected on the system during POST.

    May also be shown as 806f000f22010bff or 0x806f000f22010bff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0850
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-22010cff : CPU voltage mismatch detected on [ProcessorElementName].

    IMM has detected a CPU voltage mismatch with the CPU socket voltage.

    May also be shown as 806f000f22010cff or 0x806f000f22010cff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0050
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-2201ffff : The System [ComputerSystemElementName] encountered a POST Error.

    IMM has detected a Post Error.

    May also be shown as 806f000f2201ffff or 0x806f000f2201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0184
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220201ff : The System [ComputerSystemElementName] has detected no memory in the system.

    IMM has detected no memory in the system.

    May also be shown as 806f000f220201ff or 0x806f000f220201ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0794
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220202ff : Subsystem [MemoryElementName] has insufficient memory for operation.

    IMM has detected that the usable Memory is insufficient for operation.

    May also be shown as 806f000f220202ff or 0x806f000f220202ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0132
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220203ff : The System [ComputerSystemElementName] encountered firmware error - unrecoverable boot device failure.

    IMM has detected that System Firmware Error Unrecoverable boot device failure has occurred.

    May also be shown as 806f000f220203ff or 0x806f000f220203ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0770
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220204ff : The System [ComputerSystemElementName]has encountered a motherboard failure.

    IMM has detected a fatal motherboard error in the system.

    May also be shown as 806f000f220204ff or 0x806f000f220204ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0795
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-220207ff : The System [ComputerSystemElementName] encountered firmware error - unrecoverable keyboard failure.

    IMM has detected that System Firmware Error Unrecoverable Keyboard failure has occurred.

    May also be shown as 806f000f220207ff or 0x806f000f220207ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0764
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-22020aff : The System [ComputerSystemElementName] encountered firmware error - no video device detected.

    IMM has detected that System Firmware Error No video device detected has occurred.

    May also be shown as 806f000f22020aff or 0x806f000f22020aff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0766
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-22020bff : Firmware BIOS (ROM) corruption was detected on system [ComputerSystemElementName] during POST.

    Firmware BIOS (ROM) corruption was detected on the system during POST.

    May also be shown as 806f000f22020bff or 0x806f000f22020bff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0850
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-22020cff : CPU voltage mismatch detected on [ProcessorElementName].

    IMM has detected a CPU voltage mismatch with the socket voltage.

    May also be shown as 806f000f22020cff or 0x806f000f22020cff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0050
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f000f-2202ffff : The System [ComputerSystemElementName] encountered a POST Error.

    IMM has detected a Post Error.

    May also be shown as 806f000f2202ffff or 0x806f000f2202ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0184
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0013-1701ffff : A diagnostic interrupt has occurred on system [ComputerSystemElementName].

    The user has pressed the NMI button or there has been a malfunction with the button.

    May also be shown as 806f00131701ffff or 0x806f00131701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0222
    User Response

    If the NMI button has not been pressed, complete the following steps:

    1. Make sure that the NMI button is not pressed.
    2. Replace the system board (Trained service personnel only).
  • 806f001e-2201ffff : No bootable media available for system [ComputerSystemElementName].

    This message is for the use case when an implementation has detected a System with No Bootable Media.

    May also be shown as 806f001e2201ffff or 0x806f001e2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0286
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0021-0b01ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault in PCIe slot 1.

    May also be shown as 806f00210b01ffff or 0x806f00210b01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    Replace PCIe card
  • 806f0021-0b02ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault in PCIe slot 2.

    May also be shown as 806f00210b02ffff or 0x806f00210b02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    Replace PCIe card
  • 806f0021-0b03ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IIMM has detected a Fault in PCIe slot 3.

    May also be shown as 806f00210b03ffff or 0x806f00210b03ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    Replace PCIe card
  • 806f0021-0b04ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault in PCIe slot 4.

    May also be shown as 806f00210b04ffff or 0x806f00210b04ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    Replace PCIe card
  • 806f0021-0b05ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault in PCIe slot 5.

    May also be shown as 806f00210b05ffff or 0x806f00210b05ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    Replace PCIe card
  • 806f0021-0b06ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault in PCIe slot 6.

    May also be shown as 806f00210b06ffff or 0x806f00210b06ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    Replace PCIe card
  • 806f0021-0b07ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault in PCIe slot 7.

    May also be shown as 806f00210b07ffff or 0x806f00210b07ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    Replace PCIe card
  • 806f0021-0b08ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault in PCIe slot 8.

    May also be shown as 806f00210b08ffff or 0x806f00210b08ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    Replace PCIe card
  • 806f0021-2201ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected No Op ROM Space.

    May also be shown as 806f00212201ffff or 0x806f00212201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0021-2582ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName].

    IMM has detected a fault in one of the PCI slots or the PCI bus without isolating the to a slot.

    May also be shown as 806f00212582ffff or 0x806f00212582ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0023-2101ffff : Watchdog Timer expired for [WatchdogElementName].

    The IPMI Watchdog Timer has expired.

    May also be shown as 806f00232101ffff or 0x806f00232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0368
    User Response
    Information only; no action is required.
  • 806f0028-2101ffff : Sensor [SensorElementName] is unavailable or degraded on management system [ComputerSystemElementName].

    Trusted Platform Module(TPM) initialization or start up commands have failed.

    May also be shown as 806f00282101ffff or 0x806f00282101ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0398
    User Response
    1. Reboot the system.
    2. If error persists, or boot is unsuccessful, (Trained service technician only) Replace the system board.
  • 806f0107-0301ffff : An Over-Temperature Condition has been detected on [ProcessorElementName].

    The microprocessor 1 temperature has risen above the critical level, causing a hard shutdown of the node.

    May also be shown as 806f01070301ffff or 0x806f01070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0036
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. Make sure that the microprocessor 1 heat sink is securely installed.
    6. (Trained service technician only) Make sure that the microprocessor 1 heat sink is installed correctly and the thermal material is correctly applied.
    7. (Trained service technician only) Replace microprocessor 1.
  • 806f0107-0302ffff : An Over-Temperature Condition has been detected on [ProcessorElementName].

    The microprocessor 2 temperature has risen above the critical level, causing a hard shutdown of the node.

    May also be shown as 806f01070302ffff or 0x806f01070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0036
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. Make sure that the microprocessor 2 heat sink is securely installed.
    6. (Trained service technician only) Make sure that the microprocessor 2 heat sink is installed correctly and the thermal material is correctly applied.
    7. (Trained service technician only) Replace microprocessor 2.
  • 806f0107-0303ffff : An Over-Temperature Condition has been detected on [ProcessorElementName].

    The microprocessor 3 temperature has risen above the critical level, causing a hard shutdown of the node.

    May also be shown as 806f01070303ffff or 0x806f01070303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0036
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. Make sure that the microprocessor 3 heat sink is securely installed.
    6. (Trained service technician only) Make sure that the microprocessor 3 heat sink is installed correctly and the thermal material is correctly applied.
    7. (Trained service technician only) Replace microprocessor 3.
  • 806f0107-0304ffff : An Over-Temperature Condition has been detected on [ProcessorElementName].

    The microprocessor 4 temperature has risen above the critical level, causing a hard shutdown of the node.

    May also be shown as 806f01070304ffff or 0x806f01070304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0036
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan or cooling related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Ensure system cover is latched properly.
    4. Make sure that the room temperature is within operating specifications.
    5. Make sure that the microprocessor 4 heat sink is securely installed.
    6. (Trained service technician only) Make sure that the microprocessor 4 heat sink is installed correctly and the thermal material is correctly applied.
    7. (Trained service technician only) Replace microprocessor 4.
  • 806f0108-0a01ffff : [PowerSupplyElementName] has Failed.

    IMM has detected a Fault on Power Supply 1.

    May also be shown as 806f01080a01ffff or 0x806f01080a01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0086
    User Response
    Check the log for additional Power Supply Failure. Replace the Power Supply 1, if needed
  • 806f0108-0a02ffff : [PowerSupplyElementName] has Failed.

    IMM has detected a Fault on Power Supply 2.

    May also be shown as 806f01080a02ffff or 0x806f01080a02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0086
    User Response
    Check the log for additional Power Supply Failure. Replace the Power Supply 2, if needed
  • 806f0109-1381ffff : [PowerSupplyElementName] has been Power Cycled.

    System has been power cycled.

    May also be shown as 806f01091381ffff or 0x806f01091381ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0108
    User Response
    Host Power: Information only; no action is required.
  • 806f010c-2581ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected a Memory uncorrectable error in one of the DIMMs.

    May also be shown as 806f010c2581ffff or 0x806f010c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f010d-0400ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 0 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0400ffff or 0x806f010d0400ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0401ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 1 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0401ffff or 0x806f010d0401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0402ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 2 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0402ffff or 0x806f010d0402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0403ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 3 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0403ffff or 0x806f010d0403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0404ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 4 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0404ffff or 0x806f010d0404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0405ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 5 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0405ffff or 0x806f010d0405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0406ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 6 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0406ffff or 0x806f010d0406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0407ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 7 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0407ffff or 0x806f010d0407ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0408ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 8 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0408ffff or 0x806f010d0408ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0409ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 9 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0409ffff or 0x806f010d0409ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-040affff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 10 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d040affff or 0x806f010d040affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-040bffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 11 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d040bffff or 0x806f010d040bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-040cffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 12 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d040cffff or 0x806f010d040cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-040dffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 13 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d040dffff or 0x806f010d040dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-040effff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 14 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d040effff or 0x806f010d040effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-040fffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 15 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d040fffff or 0x806f010d040fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0410ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 16 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0410ffff or 0x806f010d0410ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0411ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 17 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0411ffff or 0x806f010d0411ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0412ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 18 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0412ffff or 0x806f010d0412ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0413ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 19 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0413ffff or 0x806f010d0413ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0414ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 20 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0414ffff or 0x806f010d0414ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0415ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 21 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0415ffff or 0x806f010d0415ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0416ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 22 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0416ffff or 0x806f010d0416ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0417ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 23 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0417ffff or 0x806f010d0417ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0418ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 24 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0418ffff or 0x806f010d0418ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-0419ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 25 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d0419ffff or 0x806f010d0419ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-041affff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 26 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d041affff or 0x806f010d041affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-041bffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 27 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d041bffff or 0x806f010d041bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-041cffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 28 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d041cffff or 0x806f010d041cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-041dffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 29 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d041dffff or 0x806f010d041dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-041effff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 30 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d041effff or 0x806f010d041effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010d-041fffff : The [StorageVolumeElementName] has been disabled due to a detected fault.

    The drive 31 has been disabled (defunct) due to a fault detected by the controller.

    May also be shown as 806f010d041fffff or 0x806f010d041fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
    2. Check IBM Support site for firmware updates related to your particular drive and RAID controller firmware and device driver.
    3. Check for any other RAID related errors.
    4. Replace the drive.
  • 806f010f-2201ffff : The System [ComputerSystemElementName] encountered a firmware hang.

    IMM has detected a System Firmware Hang.

    May also be shown as 806f010f2201ffff or 0x806f010f2201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Boot failure
    SNMP Trap ID
    25
    CIM Information
    Prefix: PLAT ID: 0186
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0113-0301ffff : A bus timeout has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Timeout.

    May also be shown as 806f01130301ffff or 0x806f01130301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0224
    User Response
    Try to reboot the system to recovery
  • 806f0113-0302ffff : A bus timeout has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Timeout.

    May also be shown as 806f01130302ffff or 0x806f01130302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0224
    User Response
    Try to reboot the system to recovery
  • 806f0113-0303ffff : A bus timeout has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Timeout.

    May also be shown as 806f01130303ffff or 0x806f01130303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0224
    User Response
    Try to reboot the system to recovery
  • 806f0113-0304ffff : A bus timeout has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Timeout.

    May also be shown as 806f01130304ffff or 0x806f01130304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0224
    User Response
    Try to reboot the system to recovery
  • 806f0113-1701ffff : A bus timeout has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Timeout.

    May also be shown as 806f01131701ffff or 0x806f01131701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0224
    User Response
    Information only; no action is required.
  • 806f011b-0701ffff : The connector [PhysicalConnectorElementName] has encountered a configuration error.

    IMM has detected Interconnect Configuration Error.

    May also be shown as 806f011b0701ffff or 0x806f011b0701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0266
    User Response

    FPGA Comm Err:

    1. AC cycle the machine.
    2. Update IMM FW to the latest level.
    3. (Trained service technician only) If error persists, replace system board.

    USB Detect:

    1. Reinsert the USB/Video cable.
    2. Replace the USB/Video cable.
  • 806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by [WatchdogElementName].

    The IPMI Watchdog Timer has expired. A reboot of the system was initiated.

    May also be shown as 806f01232101ffff or 0x806f01232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0370
    User Response
    Information only; no action is required.
  • 806f0125-0c01ffff : [ManagedElementName] detected as absent.

    IMM has detected the Operator Information panel is absent.

    May also be shown as 806f01250c01ffff or 0x806f01250c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0392
    User Response
    1. Reinsert or replace the operator information panel cable.
    2. Replace the operator information panel.
  • 806f0207-0301ffff : [ProcessorElementName] has Failed with FRB1/BIST condition.

    IMM has detected a Miroprocessor 1 Failed - FRB1/BIST condition.

    May also be shown as 806f02070301ffff or 0x806f02070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0044
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0207-0302ffff : [ProcessorElementName] has Failed with FRB1/BIST condition.

    IMM has detected a Miroprocessor 2 Failed - FRB1/BIST condition.

    May also be shown as 806f02070302ffff or 0x806f02070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0044
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0207-0303ffff : [ProcessorElementName] has Failed with FRB1/BIST condition.

    IMM has detected a Miroprocessor 3 Failed - FRB1/BIST condition.

    May also be shown as 806f02070303ffff or 0x806f02070303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0044
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0207-0304ffff : [ProcessorElementName] has Failed with FRB1/BIST condition.

    IMM has detected a Miroprocessor 4 Failed - FRB1/BIST condition.

    May also be shown as 806f02070304ffff or 0x806f02070304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0044
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0207-2583ffff : [ProcessorElementName] has Failed with FRB1/BIST condition.

    IMM has detected a Processor Failed - FRB1/BIST condition.

    May also be shown as 806f02072583ffff or 0x806f02072583ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0044
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f020d-0400ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 0.

    May also be shown as 806f020d0400ffff or 0x806f020d0400ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0401ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 1.

    May also be shown as 806f020d0401ffff or 0x806f020d0401ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0402ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 2.

    May also be shown as 806f020d0402ffff or 0x806f020d0402ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0403ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 3.

    May also be shown as 806f020d0403ffff or 0x806f020d0403ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0404ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 4.

    May also be shown as 806f020d0404ffff or 0x806f020d0404ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0405ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 5.

    May also be shown as 806f020d0405ffff or 0x806f020d0405ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0406ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 6.

    May also be shown as 806f020d0406ffff or 0x806f020d0406ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0407ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 7.

    May also be shown as 806f020d0407ffff or 0x806f020d0407ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0408ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 8.

    May also be shown as 806f020d0408ffff or 0x806f020d0408ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0409ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 9.

    May also be shown as 806f020d0409ffff or 0x806f020d0409ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-040affff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 10.

    May also be shown as 806f020d040affff or 0x806f020d040affff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-040bffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 11.

    May also be shown as 806f020d040bffff or 0x806f020d040bffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-040cffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 12.

    May also be shown as 806f020d040cffff or 0x806f020d040cffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-040dffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 13.

    May also be shown as 806f020d040dffff or 0x806f020d040dffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-040effff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 14.

    May also be shown as 806f020d040effff or 0x806f020d040effff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-040fffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 15.

    May also be shown as 806f020d040fffff or 0x806f020d040fffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0410ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 16.

    May also be shown as 806f020d0410ffff or 0x806f020d0410ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0411ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 17.

    May also be shown as 806f020d0411ffff or 0x806f020d0411ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0412ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 18.

    May also be shown as 806f020d0412ffff or 0x806f020d0412ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0413ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 19.

    May also be shown as 806f020d0413ffff or 0x806f020d0413ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0414ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 20.

    May also be shown as 806f020d0414ffff or 0x806f020d0414ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0415ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 21.

    May also be shown as 806f020d0415ffff or 0x806f020d0415ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0416ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 22.

    May also be shown as 806f020d0416ffff or 0x806f020d0416ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0417ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 23.

    May also be shown as 806f020d0417ffff or 0x806f020d0417ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0418ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 24.

    May also be shown as 806f020d0418ffff or 0x806f020d0418ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-0419ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 25.

    May also be shown as 806f020d0419ffff or 0x806f020d0419ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-041affff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 26.

    May also be shown as 806f020d041affff or 0x806f020d041affff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-041bffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 27.

    May also be shown as 806f020d041bffff or 0x806f020d041bffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-041cffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 28.

    May also be shown as 806f020d041cffff or 0x806f020d041cffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-041dffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 29.

    May also be shown as 806f020d041dffff or 0x806f020d041dffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-041effff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 30.

    May also be shown as 806f020d041effff or 0x806f020d041effff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020d-041fffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    Failure predicted (PFA) on the hard drive 31.

    May also be shown as 806f020d041fffff or 0x806f020d041fffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    Replace the hard disk drive at the next maintenance period.
  • 806f020f-220100ff : Unspecified System Firmware Progress

    The System [ComputerSystemElementName] encountered firmware progress - Unspecified System Firmware Progress

    May also be shown as 806f020f220100ff or 0x806f020f220100ff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0854
    User Response
    Information only; no action is required.
  • 806f020f-220105ff : User initiated F1 setup

    The System [ComputerSystemElementName] encountered firmware progress - User initiated F1 setup.

    May also be shown as 806f020f220105ff or 0x806f020f220105ff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0726
    User Response
    Information only; no action is required.
  • 806f020f-220113ff : Start OS boot process

    The System [ComputerSystemElementName] encountered firmware progress - start OS boot process

    May also be shown as 806f020f220113ff or 0x806f020f220113ff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0760
    User Response
    Information only; no action is required.
  • 806f0223-2101ffff : Powering off system [ComputerSystemElementName] initiated by [WatchdogElementName].

    The IPMI Watchdog Timer has expired. The system was powered off.

    May also be shown as 806f02232101ffff or 0x806f02232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0372
    User Response
    Information only; no action is required.
  • 806f0308-0a01ffff : [PowerSupplyElementName] has lost input.

    Power Supply 1 AC input has been lost.

    May also be shown as 806f03080a01ffff or 0x806f03080a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0100
    User Response
    Information only; no action is required.
  • 806f0308-0a02ffff : [PowerSupplyElementName] has lost input.

    Power Supply 2 AC input has been lost.

    May also be shown as 806f03080a02ffff or 0x806f03080a02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0100
    User Response
    Information only; no action is required.
  • 806f030c-2581ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected a Memory Scrub failure.

    May also be shown as 806f030c2581ffff or 0x806f030c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0313-1701ffff : A software NMI has occurred on system [ComputerSystemElementName].

    A software NMI has occurred. Your system may have been rebooted, depending on the configuration setting.

    May also be shown as 806f03131701ffff or 0x806f03131701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0228
    User Response
    Check Operating System logs and resolve any issues related to the NMI.
  • 806f0323-2101ffff : Power cycle of system [ComputerSystemElementName] initiated by watchdog [WatchdogElementName].

    The IPMI Watchdog Timer has expired. The system was powered off and powered on.

    May also be shown as 806f03232101ffff or 0x806f03232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0374
    User Response
    Information only; no action is required.
  • 806f040c-2581ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName].

    IMM has detected that Memory has been Disabled.

    May also be shown as 806f040c2581ffff or 0x806f040c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0507-0301ffff : [ProcessorElementName] has a Configuration Mismatch.

    IMM has detected a Processor Configuration Mismatch on CPU 1.

    May also be shown as 806f05070301ffff or 0x806f05070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0062
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0507-0302ffff : [ProcessorElementName] has a Configuration Mismatch.

    IMM has detected a Processor Configuration Mismatch on CPU 2.

    May also be shown as 806f05070302ffff or 0x806f05070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0062
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0507-0303ffff : [ProcessorElementName] has a Configuration Mismatch.

    IMM has detected a Processor Configuration Mismatch on CPU 3.

    May also be shown as 806f05070303ffff or 0x806f05070303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0062
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0507-0304ffff : [ProcessorElementName] has a Configuration Mismatch.

    IMM has detected a Processor Configuration Mismatch on CPU 4.

    May also be shown as 806f05070304ffff or 0x806f05070304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0062
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0507-2583ffff : [ProcessorElementName] has a Configuration Mismatch.

    IMM has detected a Processor Configuration Mismatch has occurred.

    May also be shown as 806f05072583ffff or 0x806f05072583ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0062
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f050c-2581ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2581ffff or 0x806f050c2581ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f050d-0400ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0400ffff or 0x806f050d0400ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0401ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0401ffff or 0x806f050d0401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0402ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0402ffff or 0x806f050d0402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0403ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0403ffff or 0x806f050d0403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0404ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0404ffff or 0x806f050d0404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0405ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0405ffff or 0x806f050d0405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0406ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0406ffff or 0x806f050d0406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0407ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0407ffff or 0x806f050d0407ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0408ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0408ffff or 0x806f050d0408ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0409ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0409ffff or 0x806f050d0409ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-040affff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d040affff or 0x806f050d040affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-040bffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d040bffff or 0x806f050d040bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-040cffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d040cffff or 0x806f050d040cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-040dffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d040dffff or 0x806f050d040dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-040effff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d040effff or 0x806f050d040effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-040fffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d040fffff or 0x806f050d040fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0410ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0410ffff or 0x806f050d0410ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0411ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0411ffff or 0x806f050d0411ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0412ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0412ffff or 0x806f050d0412ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0413ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0413ffff or 0x806f050d0413ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0414ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0414ffff or 0x806f050d0414ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0415ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0415ffff or 0x806f050d0415ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0416ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0416ffff or 0x806f050d0416ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0417ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0417ffff or 0x806f050d0417ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0418ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0418ffff or 0x806f050d0418ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0419ffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d0419ffff or 0x806f050d0419ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-041affff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d041affff or 0x806f050d041affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-041bffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d041bffff or 0x806f050d041bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-041cffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d041cffff or 0x806f050d041cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-041dffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d041dffff or 0x806f050d041dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-041effff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d041effff or 0x806f050d041effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-041fffff : Array [ComputerSystemElementName] is in critical condition.

    The Drive is part of an RAID array that is in critical condition. Immediate action is required to avoid a system outage. To identify drives in the critical array all member drives will report this message.

    May also be shown as 806f050d041fffff or 0x806f050d041fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drive that is indicated by a lit status LED.
  • 806f052b-2101ffff : Invalid or Unsupported firmware or software was detected on system [ComputerSystemElementName].

    The IMM primary firmware image has been corrupted. The IMM is running on the backup image.

    May also be shown as 806f052b2101ffff or 0x806f052b2101ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0446
    User Response
    Reflash or update the IMM firmware.
  • 806f0607-0301ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted.

    The UEFI has detected a configuration type issue with processor 1.

    May also be shown as 806f06070301ffff or 0x806f06070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0816
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0607-0302ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted.

    The UEFI has detected a configuration type issue with processor 2.

    May also be shown as 806f06070302ffff or 0x806f06070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0816
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0607-0303ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted.

    The UEFI has detected a configuration type issue with processor 3.

    May also be shown as 806f06070303ffff or 0x806f06070303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0816
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0607-0304ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted.

    The UEFI has detected a configuration type issue with processor 4.

    May also be shown as 806f06070304ffff or 0x806f06070304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0816
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0607-2583ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted.

    The UEFI has detected a configuration type issue with the processors installed

    May also be shown as 806f06072583ffff or 0x806f06072583ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0816
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0608-2584ffff : [PowerSupplyElementName] has a Configuration Mismatch.

    IMM has detected a Power Supply with a Configuration Error.

    May also be shown as 806f06082584ffff or 0x806f06082584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0104
    User Response
    Check If Power supplies have the same AC input. Check If Power supplies have the same power rating.
  • 806f060d-0400ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0400ffff or 0x806f060d0400ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0401ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0401ffff or 0x806f060d0401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0402ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0402ffff or 0x806f060d0402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0403ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0403ffff or 0x806f060d0403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0404ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0404ffff or 0x806f060d0404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0405ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0405ffff or 0x806f060d0405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0406ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0406ffff or 0x806f060d0406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0407ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0407ffff or 0x806f060d0407ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0408ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0408ffff or 0x806f060d0408ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0409ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0409ffff or 0x806f060d0409ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-040affff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d040affff or 0x806f060d040affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-040bffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d040bffff or 0x806f060d040bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-040cffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d040cffff or 0x806f060d040cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-040dffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d040dffff or 0x806f060d040dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-040effff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d040effff or 0x806f060d040effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-040fffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d040fffff or 0x806f060d040fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0410ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0410ffff or 0x806f060d0410ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0411ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0411ffff or 0x806f060d0411ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0412ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0412ffff or 0x806f060d0412ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0413ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0413ffff or 0x806f060d0413ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0414ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0414ffff or 0x806f060d0414ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0415ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0415ffff or 0x806f060d0415ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0416ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0416ffff or 0x806f060d0416ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0417ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0417ffff or 0x806f060d0417ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0418ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0418ffff or 0x806f060d0418ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-0419ffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d0419ffff or 0x806f060d0419ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-041affff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d041affff or 0x806f060d041affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-041bffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d041bffff or 0x806f060d041bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-041cffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d041cffff or 0x806f060d041cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-041dffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d041dffff or 0x806f060d041dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-041effff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d041effff or 0x806f060d041effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f060d-041fffff : Array [ComputerSystemElementName] has failed.

    The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.

    May also be shown as 806f060d041fffff or 0x806f060d041fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    • Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
    • Replace the hard disk drives that are indicated by a lit status LED.
    • Recreate the array.
    • Restore data from backup.
  • 806f0707-0301ffff : [ProcessorElementName] in slot [SlotElementName] has been added.

    IMM has detected a Processor has been Added.

    May also be shown as 806f07070301ffff or 0x806f07070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0034
    User Response
    Information only; no action is required.
  • 806f070c-25810001 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 1 in Compute Book 1.

    May also be shown as 806f070c25810001 or 0x806f070c25810001

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810002 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 2 in Compute Book 1.

    May also be shown as 806f070c25810002 or 0x806f070c25810002

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810003 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 3 in Compute Book 1.

    May also be shown as 806f070c25810003 or 0x806f070c25810003

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810004 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 4 in Compute Book 1.

    May also be shown as 806f070c25810004 or 0x806f070c25810004

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810005 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 5 in Compute Book 1.

    May also be shown as 806f070c25810005 or 0x806f070c25810005

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810006 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 6 in Compute Book 1.

    May also be shown as 806f070c25810006 or 0x806f070c25810006

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810007 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 7 in Compute Book 1.

    May also be shown as 806f070c25810007 or 0x806f070c25810007

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810008 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 8 in Compute Book 1.

    May also be shown as 806f070c25810008 or 0x806f070c25810008

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810009 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 9 in Compute Book 1.

    May also be shown as 806f070c25810009 or 0x806f070c25810009

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581000a : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 10 in Compute Book 1.

    May also be shown as 806f070c2581000a or 0x806f070c2581000a

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581000b : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 11 in Compute Book 1.

    May also be shown as 806f070c2581000b or 0x806f070c2581000b

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581000c : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 12 in Compute Book 1.

    May also be shown as 806f070c2581000c or 0x806f070c2581000c

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581000d : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 13 in Compute Book 1.

    May also be shown as 806f070c2581000d or 0x806f070c2581000d

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581000e : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 14 in Compute Book 1.

    May also be shown as 806f070c2581000e or 0x806f070c2581000e

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581000f : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 15 in Compute Book 1.

    May also be shown as 806f070c2581000f or 0x806f070c2581000f

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810010 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 16 in Compute Book 1.

    May also be shown as 806f070c25810010 or 0x806f070c25810010

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810011 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 17 in Compute Book 1.

    May also be shown as 806f070c25810011 or 0x806f070c25810011

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810012 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 18 in Compute Book 1.

    May also be shown as 806f070c25810012 or 0x806f070c25810012

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810013 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 19 in Compute Book 1.

    May also be shown as 806f070c25810013 or 0x806f070c25810013

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810014 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 20 in Compute Book 1.

    May also be shown as 806f070c25810014 or 0x806f070c25810014

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810015 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 21 in Compute Book 1.

    May also be shown as 806f070c25810015 or 0x806f070c25810015

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810016 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 22 in Compute Book 1.

    May also be shown as 806f070c25810016 or 0x806f070c25810016

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810017 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 23 in Compute Book 1.

    May also be shown as 806f070c25810017 or 0x806f070c25810017

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810018 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 24 in Compute Book 1.

    May also be shown as 806f070c25810018 or 0x806f070c25810018

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810019 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 25 in Compute Book 1.

    May also be shown as 806f070c25810019 or 0x806f070c25810019

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581001a : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 26 in Compute Book 1.

    May also be shown as 806f070c2581001a or 0x806f070c2581001a

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581001b : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 27 in Compute Book 1.

    May also be shown as 806f070c2581001b or 0x806f070c2581001b

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581001c : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 28 in Compute Book 1.

    May also be shown as 806f070c2581001c or 0x806f070c2581001c

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581001d : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 29 in Compute Book 1.

    May also be shown as 806f070c2581001d or 0x806f070c2581001d

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581001e : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 30 in Compute Book 1.

    May also be shown as 806f070c2581001e or 0x806f070c2581001e

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581001f : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 31 in Compute Book 1.

    May also be shown as 806f070c2581001f or 0x806f070c2581001f

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810020 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 32 in Compute Book 1.

    May also be shown as 806f070c25810020 or 0x806f070c25810020

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810021 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 33 in Compute Book 1.

    May also be shown as 806f070c25810021 or 0x806f070c25810021

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810022 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 34 in Compute Book 1.

    May also be shown as 806f070c25810022 or 0x806f070c25810022

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810023 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 35 in Compute Book 1.

    May also be shown as 806f070c25810023 or 0x806f070c25810023

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810024 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 36 in Compute Book 1.

    May also be shown as 806f070c25810024 or 0x806f070c25810024

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810025 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 37 in Compute Book 1.

    May also be shown as 806f070c25810025 or 0x806f070c25810025

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810026 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 38 in Compute Book 1.

    May also be shown as 806f070c25810026 or 0x806f070c25810026

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810027 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 39 in Compute Book 1.

    May also be shown as 806f070c25810027 or 0x806f070c25810027

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810028 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 40 in Compute Book 1.

    May also be shown as 806f070c25810028 or 0x806f070c25810028

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810029 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 41 in Compute Book 1.

    May also be shown as 806f070c25810029 or 0x806f070c25810029

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581002a : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 42 in Compute Book 1.

    May also be shown as 806f070c2581002a or 0x806f070c2581002a

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581002b : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 43 in Compute Book 1.

    May also be shown as 806f070c2581002b or 0x806f070c2581002b

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581002c : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 44 in Compute Book 1.

    May also be shown as 806f070c2581002c or 0x806f070c2581002c

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581002d : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 45 in Compute Book 1.

    May also be shown as 806f070c2581002d or 0x806f070c2581002d

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581002e : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 46 in Compute Book 1.

    May also be shown as 806f070c2581002e or 0x806f070c2581002e

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581002f : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 47 in Compute Book 1.

    May also be shown as 806f070c2581002f or 0x806f070c2581002f

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-25810030 : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory configuration error has occurred on DIMM 48 in Compute Book 1.

    May also be shown as 806f070c25810030 or 0x806f070c25810030

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070c-2581ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that a Memory DIMM configuration error has occurred.

    May also be shown as 806f070c2581ffff or 0x806f070c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f070d-0400ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0400ffff or 0x806f070d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0401ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0401ffff or 0x806f070d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0402ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0402ffff or 0x806f070d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0403ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0403ffff or 0x806f070d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0404ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0404ffff or 0x806f070d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0405ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0405ffff or 0x806f070d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0406ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0406ffff or 0x806f070d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0407ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0407ffff or 0x806f070d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0408ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0408ffff or 0x806f070d0408ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0409ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0409ffff or 0x806f070d0409ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-040affff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d040affff or 0x806f070d040affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-040bffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d040bffff or 0x806f070d040bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-040cffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d040cffff or 0x806f070d040cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-040dffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d040dffff or 0x806f070d040dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-040effff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d040effff or 0x806f070d040effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-040fffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d040fffff or 0x806f070d040fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0410ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0410ffff or 0x806f070d0410ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0411ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0411ffff or 0x806f070d0411ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0412ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0412ffff or 0x806f070d0412ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0413ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0413ffff or 0x806f070d0413ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0414ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0414ffff or 0x806f070d0414ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0415ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0415ffff or 0x806f070d0415ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0416ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0416ffff or 0x806f070d0416ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0417ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0417ffff or 0x806f070d0417ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0418ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0418ffff or 0x806f070d0418ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-0419ffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0419ffff or 0x806f070d0419ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-041affff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d041affff or 0x806f070d041affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-041bffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d041bffff or 0x806f070d041bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-041cffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d041cffff or 0x806f070d041cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-041dffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d041dffff or 0x806f070d041dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-041effff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d041effff or 0x806f070d041effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f070d-041fffff : Rebuild in progress for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d041fffff or 0x806f070d041fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    Information only; no action is required.
  • 806f072b-2101ffff : A successful software or firmware change was detected on system [ComputerSystemElementName].

    IMM has been recovered from a system firmware problem automatically.

    May also be shown as 806f072b2101ffff or 0x806f072b2101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0450
    User Response
    Information only; no action is required.
  • 806f072b-2201ffff : A successful software or firmware change was detected on system [ComputerSystemElementName].

    UEFI has been recovered from a firmware corruption by IMM automatically.

    May also be shown as 806f072b2201ffff or 0x806f072b2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0450
    User Response
    Information only; no action is required.
  • 806f0807-0301ffff : [ProcessorElementName] has been Disabled.

    IMM has detected that Processor 1 has been disabled.

    May also be shown as 806f08070301ffff or 0x806f08070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0061
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0807-0302ffff : [ProcessorElementName] has been Disabled.

    IMM has detected that Processor 2 has been disabled.

    May also be shown as 806f08070302ffff or 0x806f08070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0061
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0807-0303ffff : [ProcessorElementName] has been Disabled.

    IMM has detected that Processor 3 has been disabled.

    May also be shown as 806f08070303ffff or 0x806f08070303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0061
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0807-0304ffff : [ProcessorElementName] has been Disabled.

    IMM has detected that Processor 4 has been disabled.

    May also be shown as 806f08070304ffff or 0x806f08070304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0061
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0807-2583ffff : [ProcessorElementName] has been Disabled.

    IMM has detected a Processor has been Disabled.

    May also be shown as 806f08072583ffff or 0x806f08072583ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0061
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0813-2581ffff : An Uncorrectable Bus Error has occurred on bus [SensorElementName].

    IMM has detected a Bus Uncorrectable Error.

    May also be shown as 806f08132581ffff or 0x806f08132581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0240
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0813-2582ffff : An Uncorrectable Bus Error has occurred on bus [SensorElementName].

    IMM has detected a Bus Uncorrectable Error.

    May also be shown as 806f08132582ffff or 0x806f08132582ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0240
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0813-2583ffff : An Uncorrectable Bus Error has occurred on bus [SensorElementName].

    IMM has detected a Bus Uncorrectable Error.

    May also be shown as 806f08132583ffff or 0x806f08132583ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0240
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0823-2101ffff : Watchdog Timer interrupt occurred for [WatchdogElementName].

    The Watchdog Timer has expired. A watchdog interrupt has occurred.

    May also be shown as 806f08232101ffff or 0x806f08232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0376
    User Response
    Information only; no action is required.
  • 806f090c-2581ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.

    An implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2581ffff or 0x806f090c2581ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan, cooling, or power related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Make sure that the room temperature is within operating specifications.
  • 806f0a07-0301ffff : [ProcessorElementName] is operating in a Degraded State.

    The processor 1 is being throttled due to thermal or power conditions.

    May also be shown as 806f0a070301ffff or 0x806f0a070301ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0038
    User Response

    Check the IMM event log for any fan, cooling, or power related issues.

    For a thermal condition:

    1. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    2. Make sure that the room temperature is within operating specifications.

    For a power condition:

    1. If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input
    2. If using a 900 Watt rated power supply (connected at either 110V or 220 V ), may need to upgrade to a 1400 Watt rated power supply (connected at 220V).
  • 806f0a07-0302ffff : [ProcessorElementName] is operating in a Degraded State.

    The processor 2 is being throttled due to thermal or power conditions.

    May also be shown as 806f0a070302ffff or 0x806f0a070302ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0038
    User Response

    Check the IMM event log for any fan, cooling, or power related issues.

    For a thermal condition:

    1. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    2. Make sure that the room temperature is within operating specifications.

    For a power condition:

    1. If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input
    2. If using a 900 Watt rated power supply (connected at either 110V or 220 V ), may need to upgrade to a 1400 Watt rated power supply (connected at 220V).
  • 806f0a07-0303ffff : [ProcessorElementName] is operating in a Degraded State.

    The processor 3 is being throttled due to thermal or power conditions.

    May also be shown as 806f0a070303ffff or 0x806f0a070303ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0038
    User Response

    Check the IMM event log for any fan, cooling, or power related issues.

    For a thermal condition:

    1. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    2. Make sure that the room temperature is within operating specifications.

    For a power condition:

    1. If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input
    2. If using a 900 Watt rated power supply (connected at either 110V or 220 V ), may need to upgrade to a 1400 Watt rated power supply (connected at 220V).
  • 806f0a07-0304ffff : [ProcessorElementName] is operating in a Degraded State.

    The processor 4 is being throttled due to thermal or power conditions.

    May also be shown as 806f0a070304ffff or 0x806f0a070304ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0038
    User Response

    Check the IMM event log for any fan, cooling, or power related issues.

    For a thermal condition:

    1. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    2. Make sure that the room temperature is within operating specifications.

    For a power condition:

    1. If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input
    2. If using a 900 Watt rated power supply (connected at either 110V or 220 V ), may need to upgrade to a 1400 Watt rated power supply (connected at 220V).
  • 806f0a0c-2581ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected an over temperature condition on the memory.

    May also be shown as 806f0a0c2581ffff or 0x806f0a0c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response

    Complete the following steps:

    1. Check the IMM event log for any fan, cooling, or power related issues.
    2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
    3. Make sure that the room temperature is within operating specifications.
  • 806f0a13-0301ffff : A Fatal Bus Error has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Fatal Error.

    May also be shown as 806f0a130301ffff or 0x806f0a130301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0244
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0a13-0302ffff : A Fatal Bus Error has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Fatal Error.

    May also be shown as 806f0a130302ffff or 0x806f0a130302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0244
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0a13-0303ffff : A Fatal Bus Error has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Fatal Error.

    May also be shown as 806f0a130303ffff or 0x806f0a130303ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0244
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0a13-0304ffff : A Fatal Bus Error has occurred on bus [SensorElementName].

    This message is for the use case when an implementation has detected a Bus Fatal Error.

    May also be shown as 806f0a130304ffff or 0x806f0a130304ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0244
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0a13-2401ffff : A Fatal Bus Error has occurred on bus [SensorElementName].

    IMM has detected a Bus Fatal Error.

    May also be shown as 806f0a132401ffff or 0x806f0a132401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0244
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 806f0b13-3101ffff : Bus [SensorElementName] is operating in a degraded state.

    IMM has detected that the DMI Bus is degraded.

    May also be shown as 806f0b133101ffff or 0x806f0b133101ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0246
    User Response

    Complete the following steps:

    1. AC cycle the machine
    2. Remove CPU 1 and inspect the CPU socket for bent pins.
    3. Swap CPU 1 and CPU 2. If the error goes away, replace the original CPU 1.
    4. If the problem persists, System board may need to be replaced.(Trained service personnel only)
  • 81010002-2801ffff : Numeric sensor [NumericSensorElementName] going low (lower non-critical) has deasserted.

    A previously low CMOS battery voltage has returned to above its specified threshold

    May also be shown as 810100022801ffff or 0x810100022801ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Voltage
    SNMP Trap ID
    13
    CIM Information
    Prefix: PLAT ID: 0477
    User Response
    Information only; no action is required.
  • 81010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.

    A previously low voltage has returned to above its specified threshold (sensor SysBrd 12V, SysBrd 3.3V, or SysBrd 5V).

    May also be shown as 810102020701ffff or 0x810102020701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    Information only; no action is required.
  • 81010202-2801ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.

    The previously low CMOS battery voltage has returned to above its specified threshold.

    May also be shown as 810102022801ffff or 0x810102022801ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    Information only; no action is required.
  • 81010204-1d01ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.

    IMM has detected a Fan 1 (Fan 1A Tach, Fan 1B Tach) going low has deasserted.

    May also be shown as 810102041d01ffff or 0x810102041d01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    Information only; no action is required.
  • 81010204-1d02ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.

    IMM has detected a Fan 2 (Fan 2A Tach, Fan 2B Tach) going low has deasserted.

    May also be shown as 810102041d02ffff or 0x810102041d02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    Information only; no action is required.
  • 81010204-1d03ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.

    IMM has detected a Fan 3 (Fan 3A Tach, Fan 3B Tach) going low has deasserted.

    May also be shown as 810102041d03ffff or 0x810102041d03ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    Information only; no action is required.
  • 81010204-1d04ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.

    IMM has detected a Fan 4 (Fan 4A Tach, Fan 4B Tach) going low has deasserted.

    May also be shown as 810102041d04ffff or 0x810102041d04ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    Information only; no action is required.
  • 81010204-1d05ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.

    IMM has detected a Fan 5 (Fan 5A Tach, Fan 5B Tach) going low has deasserted.

    May also be shown as 810102041d05ffff or 0x810102041d05ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    Information only; no action is required.
  • 81010204-1d06ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.

    IMM has detected a Fan 6 (Fan 6A Tach, Fan 6B Tach) going low has deasserted.

    May also be shown as 810102041d06ffff or 0x810102041d06ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    Information only; no action is required.
  • 81010701-1001ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that the PCI Riser temperature has returned to a normal range.

    May also be shown as 810107011001ffff or 0x810107011001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010701-1401ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810107011401ffff or 0x810107011401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010701-1402ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810107011402ffff or 0x810107011402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010701-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810107011403ffff or 0x810107011403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010701-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810107011404ffff or 0x810107011404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010701-1405ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810107011405ffff or 0x810107011405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010701-1406ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810107011406ffff or 0x810107011406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010701-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that the ambient temperature has returned to a normal range.

    May also be shown as 810107012701ffff or 0x810107012701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010701-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted.

    IMM has detected that the PCH temperature has returned to a normal range.

    May also be shown as 810107012d01ffff or 0x810107012d01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    Information only; no action is required.
  • 81010901-1401ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810109011401ffff or 0x810109011401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010901-1402ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810109011402ffff or 0x810109011402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010901-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810109011403ffff or 0x810109011403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010901-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810109011404ffff or 0x810109011404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010901-1405ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810109011405ffff or 0x810109011405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010901-1406ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 810109011406ffff or 0x810109011406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010901-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    IMM has detected that the ambient temperature has returned to a normal range.

    May also be shown as 810109012701ffff or 0x810109012701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010901-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    IMM has detected that the PCH temperature has returned to a normal range.

    May also be shown as 810109012d01ffff or 0x810109012d01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010902-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.

    A previously high voltage has returned to below its specified threshold (sensor SysBrd 12V, SysBrd 3.3V, or SysBrd 5V).

    May also be shown as 810109020701ffff or 0x810109020701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    Information only; no action is required.
  • 81010b01-1401ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 81010b011401ffff or 0x81010b011401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    Information only; no action is required.
  • 81010b01-1402ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 81010b011402ffff or 0x81010b011402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    Information only; no action is required.
  • 81010b01-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 81010b011403ffff or 0x81010b011403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    Information only; no action is required.
  • 81010b01-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 81010b011404ffff or 0x81010b011404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    Information only; no action is required.
  • 81010b01-1405ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 81010b011405ffff or 0x81010b011405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    Information only; no action is required.
  • 81010b01-1406ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.

    IMM has detected that a system board voltage regulator temperature has returned to the normal range.

    May also be shown as 81010b011406ffff or 0x81010b011406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    Information only; no action is required.
  • 81010b01-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.

    IMM has detected that the ambient temperature has returned to a normal range.

    May also be shown as 81010b012701ffff or 0x81010b012701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    Information only; no action is required.
  • 81010b01-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.

    IMM has detected that the PCH temperature has returned to a normal range.

    May also be shown as 81010b012d01ffff or 0x81010b012d01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    Information only; no action is required.
  • 81030006-2101ffff : Sensor [SensorElementName] has asserted.

    Signature verification of one of the Firmware Volumes or Capsules in UEFI BIOS failed.

    May also be shown as 810300062101ffff or 0x810300062101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    Automatic BIOS Recovery (ABR) should cause system to come up from UEFI image in backup bank. Reflash UEFI image in the primary bank. If error does not persist no additional recovery action is required.
  • 81030108-0a01ffff : Sensor [SensorElementName] has deasserted.

    The power supply load has returned to a normal state.

    May also be shown as 810301080a01ffff or 0x810301080a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    Information only; no action is required.
  • 8103010e-2581ffff : Sensor [SensorElementName] has deasserted.

    IMM has detected that the memory size has returned to a previous configuration.

    May also be shown as 8103010e2581ffff or 0x8103010e2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 81030112-0601ffff : Sensor [SensorElementName] has deasserted.

    This message is for the use case when system firmware has exited maintenance mode.

    May also be shown as 810301120601ffff or 0x810301120601ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    Information only; no action is required.
  • 81070101-0b09ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state.

    Temperature of ML2 Card has been back to normal from non-critical state

    May also be shown as 810701010b09ffff or 0x810701010b09ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    Information only; no action is required.
  • 8107010f-2201ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state.

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 8107010f2201ffff or 0x8107010f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    Information only; no action is required.
  • 8107010f-2582ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state.

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 8107010f2582ffff or 0x8107010f2582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    Information only; no action is required.
  • 81070114-2201ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state.

    Trusted Platform Module (TPM) event has transitioned back to a normal state.

    May also be shown as 810701142201ffff or 0x810701142201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    Information only; no action is required.
  • 81070201-0301ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected a CPU 1 Overtemp Sensor transition to less severe from critical.

    May also be shown as 810702010301ffff or 0x810702010301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070201-0302ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected a CPU 2 Overtemp Sensor transition to less severe from critical.

    May also be shown as 810702010302ffff or 0x810702010302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070201-0303ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected a CPU 3 Overtemp Sensor transition to less severe from critical.

    May also be shown as 810702010303ffff or 0x810702010303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070201-0304ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected a CPU 4 Overtemp Sensor transition to less severe from critical.

    May also be shown as 810702010304ffff or 0x810702010304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070202-0701ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    The SysBrd Fault sensor no longer detects a problem with the system board.

    May also be shown as 810702020701ffff or 0x810702020701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070204-2584ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that the power supply fan sensor has transitioned to a less severe state from a critical state.

    May also be shown as 810702042584ffff or 0x810702042584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070208-2584ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected a Sensor has transitioned to less severe state from critical.

    May also be shown as 810702082584ffff or 0x810702082584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 8107020f-2201ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that the "Drive Key Fault" sensor has transitioned to a less severe state.

    May also be shown as 8107020f2201ffff or 0x8107020f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 8107020f-2582ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that the "No I/O Resources" sensor has transitioned to a less severe state.

    May also be shown as 8107020f2582ffff or 0x8107020f2582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 81070219-0701ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    The Sys Board Fault sensor no longer detects a problem with the system board.

    May also be shown as 810702190701ffff or 0x810702190701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 8107021b-0301ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that CPU 1 has recovered from a QPI Link Error.

    May also be shown as 8107021b0301ffff or 0x8107021b0301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 8107021b-0302ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that CPU 2 has recovered from a QPI Link Error.

    May also be shown as 8107021b0302ffff or 0x8107021b0302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 8107021b-0303ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that CPU 3 has recovered from a QPI Link Error.

    May also be shown as 8107021b0303ffff or 0x8107021b0303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 8107021b-0304ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that CPU 4 has recovered from a QPI Link Error.

    May also be shown as 8107021b0304ffff or 0x8107021b0304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070221-0b09ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that ML2 card has recovered from an internal error.

    May also be shown as 810702210b09ffff or 0x810702210b09ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070221-1f01ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that CPU 1 has recovered from a QPI Link Error.

    May also be shown as 810702211f01ffff or 0x810702211f01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070221-1f02ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that CPU 2 has recovered from a QPI Link Error.

    May also be shown as 810702211f02ffff or 0x810702211f02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070221-1f03ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that CPU 3 has recovered from a QPI Link Error.

    May also be shown as 810702211f03ffff or 0x810702211f03ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070221-1f04ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical.

    IMM has detected that CPU 4 has recovered from a QPI Link Error.

    May also be shown as 810702211f04ffff or 0x810702211f04ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    Information only; no action is required.
  • 81070301-0301ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state.

    The microprocessor 1 temperature has returned to below its specified threshold.

    May also be shown as 810703010301ffff or 0x810703010301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    Information only; no action is required.
  • 81070301-0302ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state.

    The microprocessor 2 temperature has returned to below its specified threshold.

    May also be shown as 810703010302ffff or 0x810703010302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    Information only; no action is required.
  • 81070301-0303ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state.

    The microprocessor 3 temperature has returned to below its specified threshold.

    May also be shown as 810703010303ffff or 0x810703010303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    Information only; no action is required.
  • 81070301-0304ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state.

    The microprocessor 4 temperature has returned to below its specified threshold.

    May also be shown as 810703010304ffff or 0x810703010304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    Information only; no action is required.
  • 81070301-0b09ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state.

    The ML2 Card temperature has returned to below its specified threshold.

    May also be shown as 810703010b09ffff or 0x810703010b09ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    Information only; no action is required.
  • 81070319-2201ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state.

    System has been recovered from S3 power state resume failure.

    May also be shown as 810703192201ffff or 0x810703192201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    Information only; no action is required.
  • 81070603-0701ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable.

    IMM has detected that the Sensor is no longer in a fault condition.

    May also be shown as 810706030701ffff or 0x810706030701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    Information only; no action is required.
  • 81070603-0b01ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable.

    IMM has detected that the Sensor is no longer in a fault condition.

    May also be shown as 810706030b01ffff or 0x810706030b01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    Information only; no action is required.
  • 81070603-2584ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable.

    IMM has detected that the Sensor is no longer in a fault condition.

    May also be shown as 810706032584ffff or 0x810706032584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    Information only; no action is required.
  • 81070603-2b01ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable.

    IMM has detected that the Sensor is no longer in a fault condition.

    May also be shown as 810706032b01ffff or 0x810706032b01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    Information only; no action is required.
  • 81070608-2584ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable.

    IMM has detected that the Sensor is no longer in a fault condition. (PS 12V OC Fault, PS 12V OV Fault, PS 12V UV Fault, or PS AUX UV Fault)

    May also be shown as 810706082584ffff or 0x810706082584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    Information only; no action is required.
  • 8107060f-2201ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable.

    IMM has detected that the Trusted Platform Module (TPM) has recovered from the initialization error.

    May also be shown as 8107060f2201ffff or 0x8107060f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    Information only; no action is required.
  • 8108000f-2101ffff : Device [LogicalDeviceElementName] has been added.

    IMM has detected a Trusted Platform Module (TPM) physical presence switch was asserted.

    May also be shown as 8108000f2101ffff or 0x8108000f2101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0536
    User Response
    Information only; no action is required.
  • 810b0108-1381ffff : Redundancy Lost for [RedundancySetElementName] has deasserted.

    Power unit redundancy has been regained.

    May also be shown as 810b01081381ffff or 0x810b01081381ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Redundant Power Supply
    SNMP Trap ID
    9
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    Information only; no action is required.
  • 810b010a-1e81ffff : Redundancy Lost for [RedundancySetElementName] has deasserted.

    Fan 1 redundancy has been regained.

    May also be shown as 810b010a1e81ffff or 0x810b010a1e81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    Information only; no action is required.
  • 810b010a-1e82ffff : Redundancy Lost for [RedundancySetElementName] has deasserted.

    Fan 2 redundancy has been regained.

    May also be shown as 810b010a1e82ffff or 0x810b010a1e82ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    Information only; no action is required.
  • 810b010a-1e83ffff : Redundancy Lost for [RedundancySetElementName] has deasserted.

    Fan 3 redundancy has been regained.

    May also be shown as 810b010a1e83ffff or 0x810b010a1e83ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    Information only; no action is required.
  • 810b010a-1e84ffff : Redundancy Lost for [RedundancySetElementName] has deasserted.

    Fan 4 redundancy has been regained.

    May also be shown as 810b010a1e84ffff or 0x810b010a1e84ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    Information only; no action is required.
  • 810b010a-1e85ffff : Redundancy Lost for [RedundancySetElementName] has deasserted.

    Fan 5 redundancy has been regained.

    May also be shown as 810b010a1e85ffff or 0x810b010a1e85ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    Information only; no action is required.
  • 810b010a-1e86ffff : Redundancy Lost for [RedundancySetElementName] has deasserted.

    Fan 6 redundancy has been regained.

    May also be shown as 810b010a1e86ffff or 0x810b010a1e86ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    Information only; no action is required.
  • 810b010c-2581ffff : Redundancy Lost for [RedundancySetElementName] has deasserted.

    Memory component group has regained its redundancy

    May also be shown as 810b010c2581ffff or 0x810b010c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 810b0208-1381ffff : Redundancy Degraded for [RedundancySetElementName] has deasserted.

    Power unit has regained its redundancy

    May also be shown as 810b02081381ffff or 0x810b02081381ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Redundant Power Supply
    SNMP Trap ID
    10
    CIM Information
    Prefix: PLAT ID: 0805
    User Response
    Information only; no action is required.
  • 810b0308-1381ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has deasserted.

    Power unit has regained its redundancy.

    May also be shown as 810b03081381ffff or 0x810b03081381ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Redundant Power Supply
    SNMP Trap ID
    10
    CIM Information
    Prefix: PLAT ID: 0807
    User Response
    Information only; no action is required.
  • 810b0309-0a01ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has deasserted.

    Power unit has regained its redundancy.

    May also be shown as 810b03090a01ffff or 0x810b03090a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Redundant Power Supply
    SNMP Trap ID
    10
    CIM Information
    Prefix: PLAT ID: 0807
    User Response
    Information only; no action is required.
  • 810b030c-2581ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has deasserted.

    Memory component group has regained its redundancy.

    May also be shown as 810b030c2581ffff or 0x810b030c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0807
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 810b0508-1381ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Power unit has regained its redundancy.

    May also be shown as 810b05081381ffff or 0x810b05081381ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Redundant Power Supply
    SNMP Trap ID
    9
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    Information only; no action is required.
  • 810b0509-0a01ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Power unit has regained its redundancy.

    May also be shown as 810b05090a01ffff or 0x810b05090a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Redundant Power Supply
    SNMP Trap ID
    9
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    Information only; no action is required.
  • 810b050a-1e81ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Fan 1 has regained its redundancy.

    May also be shown as 810b050a1e81ffff or 0x810b050a1e81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    Information only; no action is required.
  • 810b050a-1e82ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Fan 2 has regained its redundancy.

    May also be shown as 810b050a1e82ffff or 0x810b050a1e82ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    Information only; no action is required.
  • 810b050a-1e83ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Fan 3 has regained its redundancy.

    May also be shown as 810b050a1e83ffff or 0x810b050a1e83ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    Information only; no action is required.
  • 810b050a-1e84ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Fan 4 has regained its redundancy.

    May also be shown as 810b050a1e84ffff or 0x810b050a1e84ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    Information only; no action is required.
  • 810b050a-1e85ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Fan 5 has regained its redundancy.

    May also be shown as 810b050a1e85ffff or 0x810b050a1e85ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    Information only; no action is required.
  • 810b050a-1e86ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Fan 6 has regained its redundancy.

    May also be shown as 810b050a1e86ffff or 0x810b050a1e86ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Fan Failure
    SNMP Trap ID
    11
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    Information only; no action is required.
  • 810b050c-2581ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.

    Memory component group has regained its redundancy.

    May also be shown as 810b050c2581ffff or 0x810b050c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0007-0301ffff : [ProcessorElementName] has Recovered from IERR.

    IMM has detected that processor 1 recovered from an IERR condition.

    May also be shown as 816f00070301ffff or 0x816f00070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0043
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0007-0302ffff : [ProcessorElementName] has Recovered from IERR.

    IMM has detected that processor 2 recovered from an IERR condition.

    May also be shown as 816f00070302ffff or 0x816f00070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0043
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0007-0303ffff : [ProcessorElementName] has Recovered from IERR.

    IMM has detected that processor 3 recovered from an IERR condition.

    May also be shown as 816f00070303ffff or 0x816f00070303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0043
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0007-0304ffff : [ProcessorElementName] has Recovered from IERR.

    IMM has detected that processor 4 recovered from an IERR condition.

    May also be shown as 816f00070304ffff or 0x816f00070304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0043
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0008-0a01ffff : [PowerSupplyElementName] has been removed from container [PhysicalPackageElementName].

    IMM has detected that Power Supply 1 has been removed.

    May also be shown as 816f00080a01ffff or 0x816f00080a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0085
    User Response
    Information only; no action is required.
  • 816f0008-0a02ffff : [PowerSupplyElementName] has been removed from container [PhysicalPackageElementName].

    IMM has detected that Power Supply 2 has been removed.

    May also be shown as 816f00080a02ffff or 0x816f00080a02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0085
    User Response
    Information only; no action is required.
  • 816f0009-1381ffff : [PowerSupplyElementName] has been turned on.

    IMM has detected that the system power has been turned on.

    May also be shown as 816f00091381ffff or 0x816f00091381ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Power On
    SNMP Trap ID
    24
    CIM Information
    Prefix: PLAT ID: 0107
    User Response
    Information only; no action is required.
  • 816f000d-0400ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 0 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0400ffff or 0x816f000d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0401ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 1 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0401ffff or 0x816f000d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0402ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 2 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0402ffff or 0x816f000d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0403ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 3 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0403ffff or 0x816f000d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0404ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 4 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0404ffff or 0x816f000d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0405ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 5 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0405ffff or 0x816f000d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0406ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 6 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0406ffff or 0x816f000d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0407ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 7 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0407ffff or 0x816f000d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0408ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 8 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0408ffff or 0x816f000d0408ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0409ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 9 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0409ffff or 0x816f000d0409ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-040affff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 10 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d040affff or 0x816f000d040affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-040bffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 11 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d040bffff or 0x816f000d040bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-040cffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 12 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d040cffff or 0x816f000d040cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-040dffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 13 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d040dffff or 0x816f000d040dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-040effff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 14 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d040effff or 0x816f000d040effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-040fffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 15 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d040fffff or 0x816f000d040fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0410ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 16 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0410ffff or 0x816f000d0410ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0411ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 17 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0411ffff or 0x816f000d0411ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0412ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 18 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0412ffff or 0x816f000d0412ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0413ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 19 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0413ffff or 0x816f000d0413ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0414ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 20 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0414ffff or 0x816f000d0414ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0415ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 21 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0415ffff or 0x816f000d0415ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0416ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 22 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0416ffff or 0x816f000d0416ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0417ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 23 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0417ffff or 0x816f000d0417ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0418ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 24 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0418ffff or 0x816f000d0418ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-0419ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 25 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d0419ffff or 0x816f000d0419ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-041affff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 26 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d041affff or 0x816f000d041affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-041bffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 27 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d041bffff or 0x816f000d041bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-041cffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 28 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d041cffff or 0x816f000d041cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-041dffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 29 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d041dffff or 0x816f000d041dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-041effff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 30 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d041effff or 0x816f000d041effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000d-041fffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName].

    Presence of drive 31 is no longer detected. If hard drive is absent from drive bay a filler is required.

    May also be shown as 816f000d041fffff or 0x816f000d041fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    • If drive was intentionally removed, no action required.
    • Make sure that the drive properly seated.
    • If drive is properly seated, replace the drive.
  • 816f000f-2201ffff : The System [ComputerSystemElementName] has detected a POST Error deassertion.

    IMM has detected that Post Error has deasserted. (ABR Status or Firmware Error).

    May also be shown as 816f000f2201ffff or 0x816f000f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0185
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f000f-2202ffff : The System [ComputerSystemElementName] has detected a POST Error deassertion.

    This message is for the use case when an implementation has detected that Post Error has deasserted.

    May also be shown as 816f000f2202ffff or 0x816f000f2202ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0185
    User Response
    Sys Boot Status :
  • 816f0013-1701ffff : System [ComputerSystemElementName] has recovered from a diagnostic interrupt.

    The system has recovered from a NMI / Diagnostic Interrupt.

    May also be shown as 816f00131701ffff or 0x816f00131701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0223
    User Response
    Information only; no action is required.
  • 816f0021-0b01ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a fault condition in PCIe slot 1 has been removed.

    May also be shown as 816f00210b01ffff or 0x816f00210b01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-0b02ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a fault condition in PCIe slot 2 has been removed.

    May also be shown as 816f00210b02ffff or 0x816f00210b02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-0b03ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a fault condition in PCIe slot 3 has been removed.

    May also be shown as 816f00210b03ffff or 0x816f00210b03ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-0b04ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a fault condition in PCIe slot 4 has been removed.

    May also be shown as 816f00210b04ffff or 0x816f00210b04ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-0b05ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a fault condition in PCIe slot 5 has been removed.

    May also be shown as 816f00210b05ffff or 0x816f00210b05ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-0b06ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a fault condition in PCIe slot 6 has been removed.

    May also be shown as 816f00210b06ffff or 0x816f00210b06ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-0b07ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a fault condition in PCIe slot 7 has been removed.

    May also be shown as 816f00210b07ffff or 0x816f00210b07ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-0b08ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a fault condition in PCIe slot 8 has been removed.

    May also be shown as 816f00210b08ffff or 0x816f00210b08ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-2201ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault condition in a slot has been removed.

    May also be shown as 816f00212201ffff or 0x816f00212201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0021-2582ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName].

    IMM has detected a Fault condition in a slot has been removed.

    May also be shown as 816f00212582ffff or 0x816f00212582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    Information only; no action is required.
  • 816f0028-2101ffff : Sensor [SensorElementName] has returned to normal on management system [ComputerSystemElementName].

    Trusted Platform Module (TPM) was initialized and started successfully.

    May also be shown as 816f00282101ffff or 0x816f00282101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0399
    User Response
    Information Only; no action is required.
  • 816f0107-0301ffff : An Over-Temperature Condition has been removed on [ProcessorElementName].

    The microprocessor 1 temperature has returned to below the critical level.

    May also be shown as 816f01070301ffff or 0x816f01070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0037
    User Response
    Information only; no action is required.
  • 816f0107-0302ffff : An Over-Temperature Condition has been removed on [ProcessorElementName].

    The microprocessor 2 temperature has returned to below the critical level.

    May also be shown as 816f01070302ffff or 0x816f01070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0037
    User Response
    Information only; no action is required.
  • 816f0107-0303ffff : An Over-Temperature Condition has been removed on [ProcessorElementName].

    The microprocessor 3 temperature has returned to below the critical level.

    May also be shown as 816f01070303ffff or 0x816f01070303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0037
    User Response
    Information only; no action is required.
  • 816f0107-0304ffff : An Over-Temperature Condition has been removed on [ProcessorElementName].

    The microprocessor 4 temperature has returned to below the critical level.

    May also be shown as 816f01070304ffff or 0x816f01070304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0037
    User Response
    Information only; no action is required.
  • 816f0108-0a01ffff : [PowerSupplyElementName] has returned to OK status.

    IMM has detected that Power Supply 1 has returned to a normal operational status.

    May also be shown as 816f01080a01ffff or 0x816f01080a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0087
    User Response
    Information only; no action is required.
  • 816f0108-0a02ffff : [PowerSupplyElementName] has returned to OK status.

    IMM has detected that Power Supply 2 has returned to a normal operational status.

    May also be shown as 816f01080a02ffff or 0x816f01080a02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0087
    User Response
    Information only; no action is required.
  • 816f010c-2581ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected a recovery from an uncorrectable memory error.

    May also be shown as 816f010c2581ffff or 0x816f010c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f010d-0400ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 0 has been enabled.

    May also be shown as 816f010d0400ffff or 0x816f010d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0401ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 1 has been enabled.

    May also be shown as 816f010d0401ffff or 0x816f010d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0402ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 2 has been enabled.

    May also be shown as 816f010d0402ffff or 0x816f010d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0403ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 3 has been enabled.

    May also be shown as 816f010d0403ffff or 0x816f010d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0404ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 4 has been enabled.

    May also be shown as 816f010d0404ffff or 0x816f010d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0405ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 5 has been enabled.

    May also be shown as 816f010d0405ffff or 0x816f010d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0406ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 6 has been enabled.

    May also be shown as 816f010d0406ffff or 0x816f010d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0407ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 7 has been enabled.

    May also be shown as 816f010d0407ffff or 0x816f010d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0408ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 8 has been enabled.

    May also be shown as 816f010d0408ffff or 0x816f010d0408ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0409ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 9 has been enabled.

    May also be shown as 816f010d0409ffff or 0x816f010d0409ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-040affff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 10 has been enabled.

    May also be shown as 816f010d040affff or 0x816f010d040affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-040bffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 11 has been enabled.

    May also be shown as 816f010d040bffff or 0x816f010d040bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-040cffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 12 has been enabled.

    May also be shown as 816f010d040cffff or 0x816f010d040cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-040dffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 13 has been enabled.

    May also be shown as 816f010d040dffff or 0x816f010d040dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-040effff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 14 has been enabled.

    May also be shown as 816f010d040effff or 0x816f010d040effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-040fffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 15 has been enabled.

    May also be shown as 816f010d040fffff or 0x816f010d040fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0410ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 16 has been enabled.

    May also be shown as 816f010d0410ffff or 0x816f010d0410ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0411ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 17 has been enabled.

    May also be shown as 816f010d0411ffff or 0x816f010d0411ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0412ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 18 has been enabled.

    May also be shown as 816f010d0412ffff or 0x816f010d0412ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0413ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 19 has been enabled.

    May also be shown as 816f010d0413ffff or 0x816f010d0413ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0414ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 20 has been enabled.

    May also be shown as 816f010d0414ffff or 0x816f010d0414ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0415ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 21 has been enabled.

    May also be shown as 816f010d0415ffff or 0x816f010d0415ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0416ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 22 has been enabled.

    May also be shown as 816f010d0416ffff or 0x816f010d0416ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0417ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 23 has been enabled.

    May also be shown as 816f010d0417ffff or 0x816f010d0417ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0418ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 24 has been enabled.

    May also be shown as 816f010d0418ffff or 0x816f010d0418ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-0419ffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 25 has been enabled.

    May also be shown as 816f010d0419ffff or 0x816f010d0419ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-041affff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 26 has been enabled.

    May also be shown as 816f010d041affff or 0x816f010d041affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-041bffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 27 has been enabled.

    May also be shown as 816f010d041bffff or 0x816f010d041bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-041cffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 28 has been enabled.

    May also be shown as 816f010d041cffff or 0x816f010d041cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-041dffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 29 has been enabled.

    May also be shown as 816f010d041dffff or 0x816f010d041dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-041effff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 30 has been enabled.

    May also be shown as 816f010d041effff or 0x816f010d041effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010d-041fffff : The [StorageVolumeElementName] has been enabled.

    The previously disabled drive 31 has been enabled.

    May also be shown as 816f010d041fffff or 0x816f010d041fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    Information only; no action is required.
  • 816f010f-2201ffff : The System [ComputerSystemElementName] has recovered from a firmware hang.

    IMM has recovered from a System Firmware Hang.

    May also be shown as 816f010f2201ffff or 0x816f010f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0187
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0113-0301ffff : Bus [SensorElementName] has recovered from a bus timeout.

    This message is for the use case when an implemenation has detected that a system has recovered from a Bus Timeout.

    May also be shown as 816f01130301ffff or 0x816f01130301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0225
    User Response
    Information only; no action is required.
  • 816f0113-0302ffff : Bus [SensorElementName] has recovered from a bus timeout.

    This message is for the use case when an implemenation has detected that a system has recovered from a Bus Timeout.

    May also be shown as 816f01130302ffff or 0x816f01130302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0225
    User Response
    Information only; no action is required.
  • 816f0113-0303ffff : Bus [SensorElementName] has recovered from a bus timeout.

    This message is for the use case when an implemenation has detected that a system has recovered from a Bus Timeout.

    May also be shown as 816f01130303ffff or 0x816f01130303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0225
    User Response
    Information only; no action is required.
  • 816f0113-0304ffff : Bus [SensorElementName] has recovered from a bus timeout.

    This message is for the use case when an implemenation has detected that a system has recovered from a Bus Timeout.

    May also be shown as 816f01130304ffff or 0x816f01130304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0225
    User Response
    Information only; no action is required.
  • 816f011b-0701ffff : The connector [PhysicalConnectorElementName] configuration error has been repaired.

    IMM has detected an Interconnect Configuration error has been repaired.

    May also be shown as 816f011b0701ffff or 0x816f011b0701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0267
    User Response
    Information only; no action is required.
  • 816f0125-0c01ffff : [ManagedElementName] detected as present.

    IMM has detected the operator information panel is present.

    May also be shown as 816f01250c01ffff or 0x816f01250c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0390
    User Response
    Information only; no action is required.
  • 816f0207-0301ffff : [ProcessorElementName] has Recovered from FRB1/BIST condition.

    IMM has detected that Processor 1 has recovered from a FRB1/BIST condition.

    May also be shown as 816f02070301ffff or 0x816f02070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0045
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0207-0302ffff : [ProcessorElementName] has Recovered from FRB1/BIST condition.

    IMM has detected that Processor 2 has recovered from a FRB1/BIST condition.

    May also be shown as 816f02070302ffff or 0x816f02070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0045
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0207-0303ffff : [ProcessorElementName] has Recovered from FRB1/BIST condition.

    IMM has detected that Processor 3 has recovered from a FRB1/BIST condition.

    May also be shown as 816f02070303ffff or 0x816f02070303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0045
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0207-0304ffff : [ProcessorElementName] has Recovered from FRB1/BIST condition.

    IMM has detected that Processor 4 has recovered from a FRB1/BIST condition.

    May also be shown as 816f02070304ffff or 0x816f02070304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0045
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0207-2583ffff : [ProcessorElementName] has Recovered from FRB1/BIST condition.

    IMM has detected that a Processor has recovered from a FRB1/BIST condition.

    May also be shown as 816f02072583ffff or 0x816f02072583ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0045
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f020d-0400ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 0 no longer exists.

    May also be shown as 816f020d0400ffff or 0x816f020d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0401ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 1 no longer exists.

    May also be shown as 816f020d0401ffff or 0x816f020d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0402ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 2 no longer exists.

    May also be shown as 816f020d0402ffff or 0x816f020d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0403ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 3 no longer exists.

    May also be shown as 816f020d0403ffff or 0x816f020d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0404ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 4 no longer exists.

    May also be shown as 816f020d0404ffff or 0x816f020d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0405ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 5 no longer exists.

    May also be shown as 816f020d0405ffff or 0x816f020d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0406ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 6 no longer exists.

    May also be shown as 816f020d0406ffff or 0x816f020d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0407ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 7 no longer exists.

    May also be shown as 816f020d0407ffff or 0x816f020d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0408ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 8 no longer exists.

    May also be shown as 816f020d0408ffff or 0x816f020d0408ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0409ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 9 no longer exists.

    May also be shown as 816f020d0409ffff or 0x816f020d0409ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-040affff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 10 no longer exists.

    May also be shown as 816f020d040affff or 0x816f020d040affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-040bffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 11 no longer exists.

    May also be shown as 816f020d040bffff or 0x816f020d040bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-040cffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 12 no longer exists.

    May also be shown as 816f020d040cffff or 0x816f020d040cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-040dffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 13 no longer exists.

    May also be shown as 816f020d040dffff or 0x816f020d040dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-040effff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 14 no longer exists.

    May also be shown as 816f020d040effff or 0x816f020d040effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-040fffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 15 no longer exists.

    May also be shown as 816f020d040fffff or 0x816f020d040fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0410ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 16 no longer exists.

    May also be shown as 816f020d0410ffff or 0x816f020d0410ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0411ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 17 no longer exists.

    May also be shown as 816f020d0411ffff or 0x816f020d0411ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0412ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 18 no longer exists.

    May also be shown as 816f020d0412ffff or 0x816f020d0412ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0413ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 19 no longer exists.

    May also be shown as 816f020d0413ffff or 0x816f020d0413ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0414ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 20 no longer exists.

    May also be shown as 816f020d0414ffff or 0x816f020d0414ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0415ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 21 no longer exists.

    May also be shown as 816f020d0415ffff or 0x816f020d0415ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0416ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 22 no longer exists.

    May also be shown as 816f020d0416ffff or 0x816f020d0416ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0417ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 23 no longer exists.

    May also be shown as 816f020d0417ffff or 0x816f020d0417ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0418ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 24 no longer exists.

    May also be shown as 816f020d0418ffff or 0x816f020d0418ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-0419ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 25 no longer exists.

    May also be shown as 816f020d0419ffff or 0x816f020d0419ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-041affff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 26 no longer exists.

    May also be shown as 816f020d041affff or 0x816f020d041affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-041bffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 27 no longer exists.

    May also be shown as 816f020d041bffff or 0x816f020d041bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-041cffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 28 no longer exists.

    May also be shown as 816f020d041cffff or 0x816f020d041cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-041dffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 29 no longer exists.

    May also be shown as 816f020d041dffff or 0x816f020d041dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-041effff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 30 no longer exists.

    May also be shown as 816f020d041effff or 0x816f020d041effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f020d-041fffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].

    The predicted failure for Drive 31 no longer exists.

    May also be shown as 816f020d041fffff or 0x816f020d041fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    Information only; no action is required.
  • 816f0308-0a01ffff : [PowerSupplyElementName] has returned to a Normal Input State.

    IMM has detected that the input power for Power Supply 1 has returned to normal.

    May also be shown as 816f03080a01ffff or 0x816f03080a01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0099
    User Response
    Information only; no action is required.
  • 816f0308-0a02ffff : [PowerSupplyElementName] has returned to a Normal Input State.

    IMM has detected that the input power for Power Supply 2 has returned to normal.

    May also be shown as 816f03080a02ffff or 0x816f03080a02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0099
    User Response
    Information only; no action is required.
  • 816f030c-2581ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered.

    IMM has detected a Memory Scrub failure recovery. (Planar DIMMs)

    May also be shown as 816f030c2581ffff or 0x816f030c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    Information only; no action is required.
  • 816f0313-1701ffff : System [ComputerSystemElementName] has recovered from an NMI.

    IMM has detected a Software NMI has been Recovered from.

    May also be shown as 816f03131701ffff or 0x816f03131701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0230
    User Response
    Information only; no action is required.
  • 816f040c-2581ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName].

    IMM has detected that Memory has been Enabled.

    May also be shown as 816f040c2581ffff or 0x816f040c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0507-0301ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch.

    Processor 1 has Recovered from a Processor Configuration Mismatch.

    May also be shown as 816f05070301ffff or 0x816f05070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0063
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0507-0302ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch.

    Processor 2 has Recovered from a Processor Configuration Mismatch.

    May also be shown as 816f05070302ffff or 0x816f05070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0063
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0507-0303ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch.

    Processor 3 has Recovered from a Processor Configuration Mismatch.

    May also be shown as 816f05070303ffff or 0x816f05070303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0063
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0507-0304ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch.

    Processor 4 has Recovered from a Processor Configuration Mismatch.

    May also be shown as 816f05070304ffff or 0x816f05070304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0063
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0507-2583ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch.

    One or more processors have recovered from a processor configuration mismatch.

    May also be shown as 816f05072583ffff or 0x816f05072583ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0063
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f050c-2581ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2581ffff or 0x816f050c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f050d-0400ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0400ffff or 0x816f050d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0401ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0401ffff or 0x816f050d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0402ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0402ffff or 0x816f050d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0403ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0403ffff or 0x816f050d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0404ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0404ffff or 0x816f050d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0405ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0405ffff or 0x816f050d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0406ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0406ffff or 0x816f050d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0407ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0407ffff or 0x816f050d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0408ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0408ffff or 0x816f050d0408ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0409ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0409ffff or 0x816f050d0409ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-040affff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d040affff or 0x816f050d040affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-040bffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d040bffff or 0x816f050d040bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-040cffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d040cffff or 0x816f050d040cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-040dffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d040dffff or 0x816f050d040dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-040effff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d040effff or 0x816f050d040effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-040fffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d040fffff or 0x816f050d040fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0410ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0410ffff or 0x816f050d0410ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0411ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0411ffff or 0x816f050d0411ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0412ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0412ffff or 0x816f050d0412ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0413ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0413ffff or 0x816f050d0413ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0414ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0414ffff or 0x816f050d0414ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0415ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0415ffff or 0x816f050d0415ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0416ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0416ffff or 0x816f050d0416ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0417ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0417ffff or 0x816f050d0417ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0418ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0418ffff or 0x816f050d0418ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-0419ffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d0419ffff or 0x816f050d0419ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-041affff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d041affff or 0x816f050d041affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-041bffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d041bffff or 0x816f050d041bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-041cffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d041cffff or 0x816f050d041cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-041dffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d041dffff or 0x816f050d041dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-041effff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d041effff or 0x816f050d041effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f050d-041fffff : Critical Array [ComputerSystemElementName] has deasserted.

    The RAID array is no longer in a critical condition.

    May also be shown as 816f050d041fffff or 0x816f050d041fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    Information only; no action is required.
  • 816f0607-0301ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has deasserted.

    An SM BIOS uncorrectable CPU complex error has been deasserted for microprocessor 1.

    May also be shown as 816f06070301ffff or 0x816f06070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0817
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0607-0302ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has deasserted.

    An SM BIOS uncorrectable CPU complex error has been deasserted for microprocessor 2.

    May also be shown as 816f06070302ffff or 0x816f06070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0817
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0607-0303ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has deasserted.

    An SM BIOS uncorrectable CPU complex error has been deasserted for microprocessor 3.

    May also be shown as 816f06070303ffff or 0x816f06070303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0817
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0607-0304ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has deasserted.

    An SM BIOS uncorrectable CPU complex error has been deasserted for microprocessor 4.

    May also be shown as 816f06070304ffff or 0x816f06070304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0817
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0607-2583ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has deasserted.

    SM BIOS Uncorrectable CPU complex error has deasserted.

    May also be shown as 816f06072583ffff or 0x816f06072583ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0817
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0608-2584ffff : [PowerSupplyElementName] Configuration is OK.

    Power Supply configuration is OK.

    May also be shown as 816f06082584ffff or 0x816f06082584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Power
    SNMP Trap ID
    4
    CIM Information
    Prefix: PLAT ID: 0105
    User Response
    Information only; no action is required.
  • 816f060d-0400ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0400ffff or 0x816f060d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0401ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0401ffff or 0x816f060d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0402ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0402ffff or 0x816f060d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0403ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0403ffff or 0x816f060d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0404ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0404ffff or 0x816f060d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0405ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0405ffff or 0x816f060d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0406ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0406ffff or 0x816f060d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0407ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0407ffff or 0x816f060d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0408ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0408ffff or 0x816f060d0408ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0409ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0409ffff or 0x816f060d0409ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-040affff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d040affff or 0x816f060d040affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-040bffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d040bffff or 0x816f060d040bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-040cffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d040cffff or 0x816f060d040cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-040dffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d040dffff or 0x816f060d040dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-040effff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d040effff or 0x816f060d040effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-040fffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d040fffff or 0x816f060d040fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0410ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0410ffff or 0x816f060d0410ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0411ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0411ffff or 0x816f060d0411ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0412ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0412ffff or 0x816f060d0412ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0413ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0413ffff or 0x816f060d0413ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0414ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0414ffff or 0x816f060d0414ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0415ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0415ffff or 0x816f060d0415ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0416ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0416ffff or 0x816f060d0416ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0417ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0417ffff or 0x816f060d0417ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0418ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0418ffff or 0x816f060d0418ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-0419ffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0419ffff or 0x816f060d0419ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-041affff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d041affff or 0x816f060d041affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-041bffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d041bffff or 0x816f060d041bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-041cffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d041cffff or 0x816f060d041cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-041dffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d041dffff or 0x816f060d041dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-041effff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d041effff or 0x816f060d041effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f060d-041fffff : Array in system [ComputerSystemElementName] has been restored.

    IMM has detected that a Failed Array has been Restored.

    May also be shown as 816f060d041fffff or 0x816f060d041fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    Information only; no action is required.
  • 816f0707-0301ffff : [ProcessorElementName] in slot [SlotElementName] has been removed.

    IMM has detected that Processor 1 has been removed.

    May also be shown as 816f07070301ffff or 0x816f07070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0035
    User Response
    Information only; no action is required.
  • 816f070c-2581ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted.

    IMM has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2581ffff or 0x816f070c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f070d-0400ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0400ffff or 0x816f070d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0401ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0401ffff or 0x816f070d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0402ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0402ffff or 0x816f070d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0403ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0403ffff or 0x816f070d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0404ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0404ffff or 0x816f070d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0405ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0405ffff or 0x816f070d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0406ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0406ffff or 0x816f070d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0407ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0407ffff or 0x816f070d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0408ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0408ffff or 0x816f070d0408ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0409ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0409ffff or 0x816f070d0409ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-040affff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d040affff or 0x816f070d040affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-040bffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d040bffff or 0x816f070d040bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-040cffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d040cffff or 0x816f070d040cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-040dffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d040dffff or 0x816f070d040dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-040effff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d040effff or 0x816f070d040effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-040fffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d040fffff or 0x816f070d040fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0410ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0410ffff or 0x816f070d0410ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0411ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0411ffff or 0x816f070d0411ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0412ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0412ffff or 0x816f070d0412ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0413ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0413ffff or 0x816f070d0413ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0414ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0414ffff or 0x816f070d0414ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0415ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0415ffff or 0x816f070d0415ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0416ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0416ffff or 0x816f070d0416ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0417ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0417ffff or 0x816f070d0417ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0418ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0418ffff or 0x816f070d0418ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-0419ffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0419ffff or 0x816f070d0419ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-041affff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d041affff or 0x816f070d041affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-041bffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d041bffff or 0x816f070d041bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-041cffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d041cffff or 0x816f070d041cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-041dffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d041dffff or 0x816f070d041dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-041effff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d041effff or 0x816f070d041effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f070d-041fffff : Rebuild completed for Array in system [ComputerSystemElementName].

    IMM has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d041fffff or 0x816f070d041fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    Information only; no action is required.
  • 816f0807-0301ffff : [ProcessorElementName] has been Enabled.

    IMM has detected Processor 1 has been Enabled.

    May also be shown as 816f08070301ffff or 0x816f08070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0060
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0807-0302ffff : [ProcessorElementName] has been Enabled.

    IMM has detected Processor 2 has been Enabled.

    May also be shown as 816f08070302ffff or 0x816f08070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0060
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0807-0303ffff : [ProcessorElementName] has been Enabled.

    IMM has detected Processor 3 has been Enabled.

    May also be shown as 816f08070303ffff or 0x816f08070303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0060
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0807-0304ffff : [ProcessorElementName] has been Enabled.

    IMM has detected Processor 4 has been Enabled.

    May also be shown as 816f08070304ffff or 0x816f08070304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0060
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0807-2583ffff : [ProcessorElementName] has been Enabled.

    IMM has detected that one or more processors have been enabled.

    May also be shown as 816f08072583ffff or 0x816f08072583ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0060
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0813-2581ffff : Bus [SensorElementName] has recovered from an Uncorrectable Bus Error.

    IMM has detected that the system has recovered from a bus uncorrectable error.

    May also be shown as 816f08132581ffff or 0x816f08132581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0241
    User Response
    Information only; no action is required.
  • 816f0813-2582ffff : Bus [SensorElementName] has recovered from an Uncorrectable Bus Error.

    IMM has detected that the system has recovered from a bus uncorrectable error.

    May also be shown as 816f08132582ffff or 0x816f08132582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0241
    User Response
    Information only; no action is required.
  • 816f0813-2583ffff : Bus [SensorElementName] has recovered from an Uncorrectable Bus Error.

    IMM has detected that the system has recovered from a bus uncorrectable error.

    May also be shown as 816f08132583ffff or 0x816f08132583ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0241
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f090c-2581ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled.

    IMM has detected Memory component group is no longer Throttled. (Planar DIMMs)

    May also be shown as 816f090c2581ffff or 0x816f090c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    Information only; no action is required.
  • 816f0a07-0301ffff : The Processor [ProcessorElementName] is no longer operating in a Degraded State.

    IMM has detected Processor 1 is no longer running in the Degraded state.

    May also be shown as 816f0a070301ffff or 0x816f0a070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0039
    User Response
    Information only; no action is required.
  • 816f0a07-0302ffff : The Processor [ProcessorElementName] is no longer operating in a Degraded State.

    IMM has detected Processor 2 is no longer running in the Degraded state.

    May also be shown as 816f0a070302ffff or 0x816f0a070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0039
  • 816f0a07-0303ffff : The Processor [ProcessorElementName] is no longer operating in a Degraded State.

    IMM has detected Processor 3 is no longer running in the Degraded state.

    May also be shown as 816f0a070303ffff or 0x816f0a070303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0039
    User Response
    Information only; no action is required.
  • 816f0a07-0304ffff : The Processor [ProcessorElementName] is no longer operating in a Degraded State.

    IMM has detected Processor 4 is no longer running in the Degraded state.

    May also be shown as 816f0a070304ffff or 0x816f0a070304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0039
    User Response
    Information only; no action is required.
  • 816f0a0c-2581ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].

    IMM has detected an Over Temperature Condition for Memory component group that has been Removed.

    May also be shown as 816f0a0c2581ffff or 0x816f0a0c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    Information only; no action is required.
  • 816f0a13-0301ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error.

    CPU 1 PECI Bus has recovered from a Fatal Bus Error.

    May also be shown as 816f0a130301ffff or 0x816f0a130301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0245
    User Response
    Information only; no action is required.
  • 816f0a13-0302ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error.

    CPU 2 PECI Bus has recovered from a Fatal Bus Error.

    May also be shown as 816f0a130302ffff or 0x816f0a130302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0245
    User Response
    Information only; no action is required.
  • 816f0a13-0303ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error.

    CPU 3 PECI Bus has recovered from a Fatal Bus Error.

    May also be shown as 816f0a130303ffff or 0x816f0a130303ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0245
    User Response
    Information only; no action is required.
  • 816f0a13-0304ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error.

    CPU 4 PECI Bus has recovered from a Fatal Bus Error.

    May also be shown as 816f0a130304ffff or 0x816f0a130304ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0245
    User Response
    Information only; no action is required.
  • 816f0a13-2401ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error.

    IMM has detected that the system has recovered from a fatal bus error.

    May also be shown as 816f0a132401ffff or 0x816f0a132401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0245
    User Response
    This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center for the appropriate user response.
  • 816f0b13-3101ffff : Bus [SensorElementName] is no longer operating in a degraded state.

    IMM has detected the DMI Bus is No Longer Degraded.

    May also be shown as 816f0b133101ffff or 0x816f0b133101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0247
    User Response
    Information only; no action is required.