80070202-0701ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state.
Sensor [SensorElementName] has transitioned to critical from a less severe state.
The Sys Board Fault sensor has detected a problem with the system board.
May also be shown as 800702020701ffff or 0x800702020701ffff
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
No
User Response
Complete the following steps:
- Remove any recently installed components.
- Try to power on the node.
- If the node successfully powers on, complete the following steps:
- Check the ServerProven website to make sure that recently installed components are compatible with the compute node.
- Inspect the previously installed components for physical damage.
- If the node does not successfully power on or if this is not the first occurrence of this problem, (trained service technician only) replace the system board.
- If the node successfully powers on, complete the following steps: