80070603-2b01ffff : Sensor [SensorElementName] has transitioned to non-recoverable.
Sensor [SensorElementName] has transitioned to non-recoverable.
IMM has detected a voltage regulator error on the microprocessor and memory expansion tray.
May also be shown as 800706032b01ffff or 0x800706032b01ffff
Severity
Error
Alert Category
Critical - Power
Serviceable
Yes
SNMP Trap ID
4
Automatically Notify Support
No
User Response
- CPU 3 VRD: Indicates a problem with either the voltage regulator for CPU3 or CPU 3 itself
- CPU 4 VRD: Indicates a problem with either the voltage regulator for CPU4 or CPU 4 itself
- DIMM 25-30 VRD: Indicates a problem with either the voltage regulator for DIMMs 25-30 or 1 or more of the following components: DIMM25-DIMM30
- DIMM 31-36 VRD: Indicates a problem with either the voltage regulator for DIMMs 31-36 or 1 or more of the following components: DIMM31-DIMM36
- DIMM 37-42 VRD: Indicates a problem with either the voltage regulator for DIMMs 37-42 or 1 or more of the following components: DIMM37-DIMM42
- DIMM 43-48 VRD: Indicates a problem with either the voltage regulator for DIMMs 43-48 or 1 or more of the following components: DIMM43-DIMM48
- Check the IMM Web event log. This event may be a symptom of an earlier error.
- Depending on the error perform the following steps.
For a CPU 3 VRD or CPU 4 VRD error:
- Replace the microprocessor and memory expansion tray.
- Replace affected microprocessor.
For a DIMM 25-30 VRD, DIMM 31-36 VRD, DIMM 37-42 VRD, or DIMM 43-48 VRD error:
- Replace DIMM(s) associated with error.
- Replace the microprocessor and memory expansion tray.