Skip to main content

A02010800 : The specified voltage lower non critical going low asserted

The specified voltage lower non critical going low asserted

Lower Non-Critical - Going Low

Severity

Warning

Serviceable

Yes

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. If the specified sensor is P3V_BAT, replace the battery.
  2. If the specified sensor is SCM_P12V_AUX, SCM_P5V_AUX, SCM_P3V3_AUX, replace the DC-SCM board.
  3. If the specified sensor is PVCCINFAON_V, PVCCFAEHVFIVRA_V, PVCCIN_V, PVCCFA_EHV_V, PVCCD_HV_V, P1V8_PCH_AUX, P1V05_PCH_AUX, P5_AUX, P3V3_AUX, PVNN_PCH_AUX, P5V, P3V3, replace the system board (trained technician only).
  4. If the specified sensor is P12V_AUX, P12V_F_HDD, P12V_R_HDD, check BMC event logs for power-supply-related issues and resolve those issues.
  5. If the problem remains, replace the system board (trained technician only).
  6. If the problem persists, collect service data log from the BMC Web interface and contact Lenovo Support .