A0201200B : The specified voltage upper non recoverable going high asserted
The specified voltage upper non recoverable going high asserted
Upper Non-Recoverable-Going High
Severity
Error
Serviceable
Yes
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- If the specified sensor is P3V_BAT, replace the Battery (trained technician only).
- If the specified sensor is SCM_P12V_AUX, SCM_P5V_AUX, SCM_P3V3_AUX, replace the DC-SCM board.
- If the specified sensor is PVCCINFAON_V, PVCCFAEHVFIVRA_V, PVCCIN_V, PVCCFA_EHV_V, PVCCD_HV_V, P1V8_PCH_AUX, P1V05_PCH_AUX, P5_AUX, P3V3_AUX, PVNN_PCH_AUX, P5V, P3V3, replace the system board (trained technician only).
- If the specified sensor is P12V_AUX, P12V_F_HDD, P12V_R_HDD, check BMC event logs for power-supply-related issues and resolve those issues.
- If the problem remains, replace the system board (trained technician only).
- If the problem persists, collect service data log from the BMC Web interface and contact Lenovo Support.