Skip to main content

A0201200B : The specified voltage upper non recoverable going high asserted

The specified voltage upper non recoverable going high asserted

Upper Non-Recoverable-Going High

Severity

Error

Serviceable

Yes

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. If the specified sensor is P3V_BAT, replace the Battery (trained technician only).
  2. If the specified sensor is SCM_P12V_AUX, SCM_P5V_AUX, SCM_P3V3_AUX, replace the DC-SCM board.
  3. If the specified sensor is PVCCINFAON_V, PVCCFAEHVFIVRA_V, PVCCIN_V, PVCCFA_EHV_V, PVCCD_HV_V, P1V8_PCH_AUX, P1V05_PCH_AUX, P5_AUX, P3V3_AUX, PVNN_PCH_AUX, P5V, P3V3, replace the system board (trained technician only).
  4. If the specified sensor is P12V_AUX, P12V_F_HDD, P12V_R_HDD, check BMC event logs for power-supply-related issues and resolve those issues.
  5. If the problem remains, replace the system board (trained technician only).
  6. If the problem persists, collect service data log from the BMC Web interface and contact Lenovo Support.