Skip to main content

A0CEF0806 : The specified memory presence detected deasserted

The specified memory presence detected deasserted

Presence Detected

Severity

Warning

Serviceable

Yes

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. If the problem persists, check whether any reported DIMMs are not properly seated. If yes, reseat them.
  2. If the problem persists, visually inspect the DIMMs for physical damage, dust, or any other contamination on the connector or circuits. If yes, dust off the DIMMs, clean the contacts, and re-install them.
  3. If the problem persists, visually inspect the DIMM slot for physical damage. Look for cracked or broken plastic on the slot. If yes, move the DIMM to another DIMM slot.
  4. If the problem persists, perform a power cycle on the server from the management console.
  5. If the problem persists, collect service data log from the BMC Web interface and contact Lenovo Support.
  6. DIMM installation rules can be found in the ThinkSystem HS350XV3 User Guide in https://pubs.lenovo.com/hs350x-v3/memory_module_replacement.