Skip to main content

B136F1004 : PCI PERR asserted

PCI PERR asserted

PCI PERR

Severity

Error

Serviceable

Yes

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. If the server and/or any attached cables were recently installed, moved, serviced or upgraded, check whether the processor, the adapter and any attached cables is properly seated and check visually whether there is any foreign material in the processor socket and any PCIe slot. If yes, reseat the processor, the adapter and any attached cables or clean the foreign material from processor socket and that PCIe slot.
  2. Reload the device driver.
  3. Check the Lenovo support site for an applicable device driver, firmware update, or other information that applies to this error. Load the new device driver and install any required firmware updates.
  4. Swap other PCIe devices in the slot, if the problem recurs on the same PCIe slot, inspect the PCIe slot for any damage. If the problem is solved, change another identical PCIe card to check whether the problem can be solved again.
  5. If the problem persists, collect service data log from the BMC Web interface and contact Lenovo Support.