Follow the instructions in this section to remove the power distribution board and PDB cage.
S002
CAUTION
The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
Disconnect all the cables from the power distribution board.
Note
When disconnecting cables, make a list of each cable and record the connectors the cable is connected to, and use the record as a cabling checklist after installing the power distribution board.
Loosen the six screws that secure the power distribution board; then, remove the power distribution board from the PDB cage.
Figure 1. Removing the power distribution board
Loosen the four screws that secure the PDB cage; then, lift the PDB cage to remove it.
If you are instructed to return the component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.