Replacing an optional ServeRAID adapter memory module

Use this information to replace an optional ServeRAID adapter memory module.

To replace an optional ServeRAID adapter memory module, complete the following steps:

  1. Read the safety information that begins in Safety and Installation guidelines.
  2. Turn off the server (see Turning off the server) and all attached peripheral devices.
  3. Disconnect all external cables and power cords.
  4. Carefully turn the server on its side so that it is lying flat, with the cover facing up.
    Attention
    Do not allow the server to fall over.
  5. Unlock and remove the left-side cover (see Removing the left-side cover).
  6. Remove the air baffle (see Removing the air baffle).
  7. Remove the fan assembly (see Removing the fan assembly).
  8. Locate the ServeRAID adapter which you will install the memory module. Remove the exiting ServeRAID adapter if necessary (see Removing an optional ServeRAID adapter memory module).
  9. Touch the static-protective package that contains the adapter to any unpainted metal surface on the server; then, remove the adapter from the package.
  10. Align the memory module with the connector on the ServeRAID adapter and push it into the connector until it is firmly seated.

  11. Reinstall the ServeRAID adapter (see Installing an adapter).
  12. Close and lock the left-side cover (see Replacing the left-side cover).
  13. Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server.

If you have other devices to install or remove, do so now. Otherwise, go to Completing the installation.