Thermal rules for server with 9005 series processors
This topic provides thermal rules for the server with 9005 series processors.
Max.Temp.: Maximum ambient temperature at sea level
FIO = riser 5 + front OCP
S/S: SAS/SATA
Any: AnyBay
S: standard
P: performance
A: advanced
NA: not applicable
Y: yes
Y* in the Middle bays or Rear bays column: yes (when no Gen5 7.68 TB or larger capacity NVMe drive or no Gen4 P5336 15.36 TB/30.72 TB/61.44 TB NVMe drive is installed)
N: no
DWCM: Direct Water Cooling Module
Group D: 9015, 9115
Group B: 9135, 9335, 9255
Group A: 9355(P), 9535, 9365, 9455(P)
Group E1: 9555(P), 9565, 9645, 9655(P), 9745, 9825, 9845
Group E2: 9375F, 9475F, 9575F
Group E3: 9175F, 9275F
Standard configurations
This section provides thermal information for standard configurations.
| Front bays | Max. Temp. | Processor | Heat sink | Air baffle | Fan type | Support ≥ 64 GB DIMM |
|---|---|---|---|---|---|---|
| 35°C | Group B, D | 2U S | S | S | N |
| Group B, A, D | 2U S | S | P | Y | ||
| Group E1 | 2U A | S | P | Y | ||
| Group B, A, D, E | DWCM | S | S | Ynote 3 | ||
| 30°C | Group E1 | 2U P | S | P | Y | |
| Group E2, E3 | 2U A | S | P | Y | ||
| 25°C | Group E2 | 2U P | S | P | Y |
When a part with active optical cable (AOC) is installed and the rate of the part is greater than 25 GB, the ambient temperature must be limited to 30°C or lower.
When the following parts are installed, the ambient temperature must be limited to 35°C or lower.
PCIe network interface cards (NICs) at a rate greater than or equal to 100 GB
Parts with AOC and at a rate of 25 GB
When standard fans are used, the max. supported ambient temperature is 30°C; when performance fans are used, the max. supported ambient temperature is 35°C.
- When ThinkSystem NVIDIA ConnectX-8 8240 400GbE / 400Gb/s IB QSFP112 2-port PCIe Gen6 x16 (Generic FW) is installed, the following requirements should be met:
The 6056 performance fan is installed.
For the server configured with 8 x 2.5" / 16 x 2.5" / 8 x 3.5" / 24 x 2.5" front drive bays, the maximum ambient temperature is limited to 30°C.
For the server configured with 12 x 3.5" front drive bays, the maximum ambient temperature is limited to 25°C.
Storage configurations without DWCM
This section provides thermal information for storage configurations without DWCM.
| Front bays | Middle bays | Rear bays | Max. Temp. | Processor | Heat sink | Air baffle | Fan type | Support ≥ 64 GB DIMM |
|---|---|---|---|---|---|---|---|---|
| N | N | 30°C | Group B, D | 2U S | S | S | N |
| N | N | 30°C | Group A | 2U P | S | S | N | |
| N | N | 30°C | Group B, D | 2U S | S | P | Y | |
| N | N | 30°C | Group A | 2U P | S | P | Y | |
| N | N | 30°C | Group E1, E2 | 2U A | S | P | Y | |
| N | Ynote 1 | 30°C | Group D | 2U S | S | P | N | |
| N | Ynote 1 | 30°C | Group B, A | 2U P | S | P | N | |
| Ynote 1 | N | 30°C | Group B, A, D | 2U P | N/A | P | N | |
| Ynote 1 | Ynote 1 | 30°C | Group B, D | 2U P | N/A | P | N | |
| N | N | 25°C | Group E1 | 2U P | S | P | Y | |
| N | N | 25°C | Group E2, E3 | 2U A | S | P | Y | |
| N | Y | 25°C | Group D | 2U S | S | P | Y | |
| N | Y | 25°C | Group B, A | 2U P | S | P | Y | |
| N | Y | 25°C | Group E3 | 2U A | S | P | Y | |
| Y | N/Y | 25°C | Group B, A, D | 2U P | NA | P | Y | |
| N | N | 30°C | Group B, D | 2U S | S | P | Y |
| N | N | 30°C | Group A | 2U P | S | P | Y | |
| N | N | 30°C | Group E1, E2 | 2U A | S | P | Y | |
| N | Y* | 30°C | Group D | 2U S | S | P | N | |
| N | Y* | 30°C | Group B, A | 2U P | S | P | N | |
| Y* | N | 30°C | Group B, A, D | 2U P | N/A | P | N | |
| Y* | Y* | 30°C | Group B, D | 2U P | N/A | P | N | |
| N | N | 25°C | Group E1 | 2U P | S | P | Y | |
| N | N | 25°C | Group E3 | 2U A | S | P | Y | |
| N | Y | 25°C | Group D | 2U S | S | P | N | |
| N | Y | 25°C | Group B, A | 2U P | S | P | N | |
| N | Y | 25°C | Group E3 | 2U A | S | P | N | |
| Y | N/Y | 25°C | Group B, A, D | 2U P | NA | P | N |
- The ambient temperature is limited to 30°C when the following NVMe drives are installed in middle or rear drive bays:
Gen5 7.68 TB or larger capacity
P5336 15.36TB or larger capacity
When a part with active optical cable (AOC) is installed and the rate of the part is greater than 25 GB, the ambient temperature must be limited to 30°C or lower.
When the following parts are installed, the ambient temperature must be limited to 35°C or lower.
PCIe network interface cards (NICs) at a rate greater than or equal to 100 GB
Parts with AOC and at a rate of 25 GB
- The maximum ambient temperature is limited to 25°C when the following drives are installed:
PS1030 6.4TB or larger capacity
PS1010 7.68TB or larger capacity
- When ThinkSystem NVIDIA ConnectX-8 8240 400GbE / 400Gb/s IB QSFP112 2-port PCIe Gen6 x16 (Generic FW) is installed, the following requirements should be met:
The 6056 performance fan is installed.
For the server configured with 8 x 2.5" / 16 x 2.5" / 8 x 3.5" / 24 x 2.5" front drive bays, the maximum ambient temperature is limited to 30°C.
For the server configured with 12 x 3.5" front drive bays, the maximum ambient temperature is limited to 25°C.
Storage configurations with DWCM
This section provides thermal information for storage configurations with DWCM.
| Front bays | Middle bays | Rear bays | Max. Temp. | Processor | Heat sink | Air baffle | Fan type | Support ≥ 64 GB DIMM |
|---|---|---|---|---|---|---|---|---|
| N | N | 35°C | Group B, A, D, E | DWCM | S | S | Ynote 1 |
| N/Y note 2 | N/Y note 2 | 35°C | Group B, A, D, E | DWCM | S | P | Y |
When standard fans are used, the max. supported ambient temperature is 30°C; when performance fans are used, the max. supported ambient temperature is 35°C.
- The ambient temperature is limited to 30°C when the following NVMe drives are installed in middle or rear drive bays:
Gen5 7.68 TB or larger capacity
Gen4 P5336 15.36T/30.72T/61.44T NVMe
- The maximum ambient temperature is limited to 25°C when the following drives are installed:
PS1030 6.4TB or larger capacity
PS1010 7.68TB or larger capacity
- When ThinkSystem NVIDIA ConnectX-8 8240 400GbE / 400Gb/s IB QSFP112 2-port PCIe Gen6 x16 (Generic FW) is installed, the following requirements should be met:
The 6056 performance fan is installed.
For the server configured with 8 x 2.5" / 16 x 2.5" / 8 x 3.5" / 24 x 2.5" front drive bays, the maximum ambient temperature is limited to 30°C.
For the server configured with 12 x 3.5" front drive bays, the maximum ambient temperature is limited to 25°C.
GPU configurations without DWCM
This section provides thermal information for GPU configurations.
For GPU configurations, group E1 processors are defined as follows: 9555(P), 9565, 9645, 9655(P), 9745, 9825, 9845, 9475F, 9575F.
Performance fans are required for servers with GPU adapters.
Half-height half-length (HHHL) single-wide (SW) GPU: A2, L4
DW GPU: A16, A30, A40, L40, L40S, A100, RTX A2000, RTX A4500, RTX A6000, RTX 4500 Ada, RTX 6000 Ada, RTX PRO 6000 Max-Q, H100, H100 NVL, AMD MI210
| Front bays | Max. Temp. | Processor | Heat sink | Air baffle | Max. GPU Qty. | ||||
|---|---|---|---|---|---|---|---|---|---|
| SW | DW (A2000) | DW (A40/L40) | 350W DW | Other DW | |||||
| 30°C | Group B, D | 2U S | S | 8 | 3 | NA | NA | NA |
| Group A | 2U P | S | 8 | 3 | NA | NA | NA | ||
| Group B, A, D | 2U P | GPU | NA | NA | 3 | 3 | 3 | ||
| 25°C | Group E1 | 2U P | S | 6 | 3 | NA | NA | NA | |
| Group E1 | 2U P | GPU | NA | NA | 2 (slot 2/5) | 2 (slot 2/5) | 2 (slot 2/5) | ||
| 30°C | Group B, D | 2U S | S | 8 | 3 | NA | NA | NA |
| Group A | 2U P | S | 8 | 3 | NA | NA | NA | ||
| Group B, A, D | 2U P | GPU | NA | NA | 2 (slot 2/5) | 2 (slot 2/5) | 3 | ||
| 25°C | Group E1 | 2U P | S | 6 | 3 | NA | NA | NA | |
| Group E1 | 2U P | GPU | NA | NA | 2 (slot 2/5) | 2 (slot 2/5) | 2 (slot 2/5) | ||
| 25°C | Group B, D | 2U S | S | 6 | 3 | NA | NA | NA |
| Group A | 2U P | S | 6 | 3 | NA | NA | NA | ||
| Group B, A, D | 2U P | GPU | NA | NA | 2 (slot 2/5) | 2 (slot 2/5) | 2 (slot 2/5) | ||
When three H100 NVLs are installed, the maximum ambient temperature is limited to 25°C in 8 x 2.5", 16 x 2.5" or 8 x 3.5" configuration with processors (TDP ≤ 300 W) installed.
When RTX 4500 Ada, RTX 6000 Ada or RTX PRO 6000 Max-Q is installed, the maximum ambient temperature is limited to 30°C in 8 x 2.5", 16 x 2.5", 24 x 2.5" or 8 x 3.5" configuration.
- When ThinkSystem NVIDIA ConnectX-8 8240 400GbE / 400Gb/s IB QSFP112 2-port PCIe Gen6 x16 (Generic FW) is installed, the following requirements should be met:
The 6056 performance fan is installed.
For the server configured with 8 x 2.5" / 16 x 2.5" / 8 x 3.5" / 24 x 2.5" front drive bays, the maximum ambient temperature is limited to 30°C.
For the server configured with 12 x 3.5" front drive bays, the maximum ambient temperature is limited to 25°C.
GPU configurations with DWCM
This section provides thermal information for GPU configurations.
For GPU configurations, group E1 processors are defined as follows: 9555(P), 9565, 9645, 9655(P), 9745, 9825, 9845, 9475F, 9575F.
Performance fans are required for servers with GPU adapters.
Half-height half-length (HHHL) single-wide (SW) GPU: A2, L4
DW GPU: A16, A30, A40, L40, L40S, A100, RTX A2000, RTX A4500, RTX A6000, RTX 4500 Ada, RTX Pro 4500 (BWE), RTX 6000 Ada, RTX PRO 6000 Max-Q, H100, H100 NVL, AMD MI210
| Front bays | Max. Temp. | Processor | Heat sink | Air baffle | Max. GPU Qty. | ||
|---|---|---|---|---|---|---|---|
| SW | DW (A2000) | Other DW | |||||
| 35°C | Group B, A, D, E1 | DWCM | S | 7 | 7 | NA |
| 35°C | Group B, A, D, E1 | DWCM | GPU | NA | NA | 3note 1 |
| 35°C | Group B, A, D, E1 | DWCM | GPU | NA | NA | 3note 2 |
When three 300W or 350W GPU adapters are installed, the maximum ambient temperature is limited to 30°C in 8 x 2.5", 8 x 3.5", 16 x 2.5", FIO or FIO + 8 x 2.5" configuration.
In 24 x 2.5" or FIO + 16 x 2.5" configuration, the maximum ambient temperature is limited to 30°C when three 300W GPU adapters are installed; the maximum ambient temperature is limited to 25°C when three 350W GPU adapters are installed.
- When three H100 NVLs are installed, the maximum ambient temperature is limited to 25°C in 8 x 2.5", 16 x 2.5" or 8 x 3.5" configuration with processors (TDP ≤ 300 W) installed.
When RTX 4500 Ada, RTX 6000 Ada or RTX PRO 6000 Max-Q is installed, the maximum ambient temperature is limited to 30°C in 8 x 2.5", 16 x 2.5", 24 x 2.5" or 8 x 3.5" configuration.
When ThinkSystem Cornelis CN5000 OPA QSFP112 HFI Adapter is installed, the GPU air baffle and 6056 performance fan must be used, and the maximum ambient temperature is limited to 30°C.
- When ThinkSystem NVIDIA ConnectX-8 8240 400GbE / 400Gb/s IB QSFP112 2-port PCIe Gen6 x16 (Generic FW) is installed, the following requirements should be met:
The 6056 performance fan is installed.
For the server configured with 8 x 2.5" / 16 x 2.5" / 8 x 3.5" / 24 x 2.5" front drive bays, the maximum ambient temperature is limited to 30°C.
For the server configured with 12 x 3.5" front drive bays, the maximum ambient temperature is limited to 25°C.