Skip to main content

Thermal rules for server with 9005 series processors

This topic provides thermal rules for the server with 9005 series processors.

Abbreviations used in tables below are defined as follows:
  • Max.Temp.: Maximum ambient temperature at sea level

  • FIO = riser 5 + front OCP

  • S/S: SAS/SATA

  • Any: AnyBay

  • S: standard

  • P: performance

  • A: advanced

  • NA: not applicable

  • Y: yes

  • Y* in the Middle bays or Rear bays column: yes (when no Gen5 7.68 TB or larger capacity NVMe drive or no Gen4 P5336 15.36 TB/30.72 TB/61.44 TB NVMe drive is installed)

  • N: no

  • DWCM: Direct Water Cooling Module

Processor groups are defined as follows:
  • Group D: 9015, 9115

  • Group B: 9135, 9335, 9255

  • Group A: 9355(P), 9535, 9365, 9455(P)

  • Group E1: 9555(P), 9565, 9645, 9655(P), 9745, 9825, 9845

  • Group E2: 9375F, 9475F, 9575F

  • Group E3: 9175F, 9275F

Standard configurations

This section provides thermal information for standard configurations.

Front baysMax. Temp.ProcessorHeat sinkAir baffleFan typeSupport ≥ 64 GB DIMM

8 x 2.5"

16 x 2.5"

8 x 3.5"

FIO

8 x2.5"+FIO

35°CGroup B, D2U SSSN
Group B, A, D2U SSPY
Group E12U ASPY
Group B, A, D, EDWCMSSY
30°CGroup E12U PSPY
Group E2, E32U ASPY
25°CGroup E22U PSPY
Note
  1. When a part with active optical cable (AOC) is installed and the rate of the part is greater than 25 GB, the ambient temperature must be limited to 30°C or lower.

  2. When the following parts are installed, the ambient temperature must be limited to 35°C or lower.

    • PCIe network interface cards (NICs) at a rate greater than or equal to 100 GB

    • Parts with AOC and at a rate of 25 GB

Storage configurations with DWCM

This section provides thermal information for storage configurations with DWCM.

Front baysMiddle baysRear baysMax. Temp.ProcessorHeat sinkAir baffleFan typeSupport ≥ 64 GB DIMM

24 x 2.5"

16 x 2.5" + FIO

12 x 3.5"

NN35°CGroup B, A, D, EDWCMSSY
N/YN/Y35°CGroup B, A, D, E note 1DWCMSPY

Storage configurations without DWCM

This section provides thermal information for storage configurations without DWCM.

Front baysMiddle baysRear baysMax. Temp.ProcessorHeat sinkAir baffleFan typeSupport ≥ 64 GB DIMM
 NN30°CGroup B, D2U SSSN
NN30°CGroup A2U PSSN
NN30°CGroup B, D2U SSPY
NN30°CGroup A2U PSPY
NN30°CGroup E1, E22U ASPY
NY*30°CGroup D2U SSPN
NY*30°CGroup B, A2U PSPN
Y*N30°CGroup B, A, D2U PN/APN
Y*Y*30°CGroup B, D2U PN/APN
NN25°CGroup E12U PSPY
NN25°CGroup E2, E32U ASPY
NY25°CGroup D2U SSPY
NY25°CGroup B, A2U PSPY
NY25°CGroup E32U ASPY
YN/Y25°CGroup B, A, D2U PNAPY
 NN30°CGroup B, D2U SSPY
NN30°CGroup A2U PSPY
NN30°CGroup E1, E22U ASPY
NY*30°CGroup D2U SSPN
NY*30°CGroup B, A2U PSPN
Y*N30°CGroup B, A, D2U PN/APN
Y*Y*30°CGroup B, D2U PN/APN
NN25°CGroup E12U PSPY
NN25°CGroup E2, E32U ASPY
NY25°CGroup D2U SSPN
NY25°CGroup B, A2U PSPN
NY25°CGroup E32U ASPN
YN/Y25°CGroup B, A, D2U PNAPN
Note
  1. The ambient temperature is limited to 30°C when the following NVMe drives are installed in middle or rear drive bays:
    • Gen5 7.68 TB or larger capacity

    • P5336 15.36TB or larger capacity

  2. When a part with active optical cable (AOC) is installed and the rate of the part is greater than 25 GB, the ambient temperature must be limited to 30°C or lower.

  3. When the following parts are installed, the ambient temperature must be limited to 35°C or lower.

    • PCIe network interface cards (NICs) at a rate greater than or equal to 100 GB

    • Parts with AOC and at a rate of 25 GB

GPU configurations

This section provides thermal information for GPU configurations.

  • Half-height half-length (HHHL) single-wide (SW) GPU: A2, L4

  • DW GPU: A16, A30, A40, L40, L40S, A100, RTX A2000, RTX A4500, RTX A6000, RTX 4500 Ada, RTX 6000 Ada, H100, H100 NVL, AMD MI210

Front baysMax. Temp.ProcessorHeat sinkAir baffleFan typeMax. GPU Qty.
SWDW (A2000)DW (A40/L40)350W DWOther DW

8 x 2.5"

8 x 3.5"

FIO

30°CGroup B, D2U SSP83NANANA
Group A2U PSP83NANANA
Group B, A, D2U PGPUPNANA333
 Group E12U PSP63NANANA
Group E12U PGPUPNANA2 (slot 2/5)2 (slot 2/5)2 (slot 2/5)

16 x 2.5"

8 x 2.5" + FIO

30°CGroup B, D2U SSP83NANANA
Group A2U PSP83NANANA
Group B, A, D2U PGPUPNANA2 (slot 2/5)2 (slot 2/5)3
25°CGroup E12U PSP63NANANA
Group E12U PGPUPNANA2 (slot 2/5)2 (slot 2/5)2 (slot 2/5)

24 x 2.5"

16 x 2.5" + FIO

25°CGroup B, D2U SSP63NANANA
Group A2U PSP63NANANA
Group B, A, D2U PGPUPNANA2 (slot 2/5)2 (slot 2/5)2 (slot 2/5)
Note
In GPU configurations with 24 x 2.5" or 16 x 2.5" + FIO front bays or GPU configurations with Group E1 processors, a part with AOC and at a rate greater than 25 GB cannot be installed on slot 3, and the following parts are not supported:
  • Broadcom 57416 10GBASE-T 2-port OCP

  • Broadcom 57454 10GBASE-T 4-port OCP