Thermal rules for server with 9005 series processors
This topic provides thermal rules for the server with 9005 series processors.
Max.Temp.: Maximum ambient temperature at sea level
FIO = riser 5 + front OCP
S/S: SAS/SATA
Any: AnyBay
S: standard
P: performance
A: advanced
NA: not applicable
Y: yes
Y* in the Middle bays or Rear bays column: yes (when no Gen5 7.68 TB or larger capacity NVMe drive or no Gen4 P5336 15.36 TB/30.72 TB/61.44 TB NVMe drive is installed)
N: no
DWCM: Direct Water Cooling Module
Group D: 9015, 9115
Group B: 9135, 9335, 9255
Group A: 9355(P), 9535, 9365, 9455(P)
Group E1: 9555(P), 9565, 9645, 9655(P), 9745, 9825, 9845
Group E2: 9375F, 9475F, 9575F
Group E3: 9175F, 9275F
Standard configurations
This section provides thermal information for standard configurations.
Front bays | Max. Temp. | Processor | Heat sink | Air baffle | Fan type | Support ≥ 64 GB DIMM |
---|---|---|---|---|---|---|
| 35°C | Group B, D | 2U S | S | S | N |
Group B, A, D | 2U S | S | P | Y | ||
Group E1 | 2U A | S | P | Y | ||
Group B, A, D, E | DWCM | S | S | Ynote 3 | ||
30°C | Group E1 | 2U P | S | P | Y | |
Group E2, E3 | 2U A | S | P | Y | ||
25°C | Group E2 | 2U P | S | P | Y |
When a part with active optical cable (AOC) is installed and the rate of the part is greater than 25 GB, the ambient temperature must be limited to 30°C or lower.
When the following parts are installed, the ambient temperature must be limited to 35°C or lower.
PCIe network interface cards (NICs) at a rate greater than or equal to 100 GB
Parts with AOC and at a rate of 25 GB
When standard fans are used, the max. supported ambient temperature is 30°C; when performance fans are used, the max. supported ambient temperature is 35°C.
Storage configurations without DWCM
This section provides thermal information for storage configurations without DWCM.
Front bays | Middle bays | Rear bays | Max. Temp. | Processor | Heat sink | Air baffle | Fan type | Support ≥ 64 GB DIMM |
---|---|---|---|---|---|---|---|---|
| N | N | 30°C | Group B, D | 2U S | S | S | N |
N | N | 30°C | Group A | 2U P | S | S | N | |
N | N | 30°C | Group B, D | 2U S | S | P | Y | |
N | N | 30°C | Group A | 2U P | S | P | Y | |
N | N | 30°C | Group E1, E2 | 2U A | S | P | Y | |
N | Ynote 1 | 30°C | Group D | 2U S | S | P | N | |
N | Ynote 1 | 30°C | Group B, A | 2U P | S | P | N | |
Ynote 1 | N | 30°C | Group B, A, D | 2U P | N/A | P | N | |
Ynote 1 | Ynote 1 | 30°C | Group B, D | 2U P | N/A | P | N | |
N | N | 25°C | Group E1 | 2U P | S | P | Y | |
N | N | 25°C | Group E2, E3 | 2U A | S | P | Y | |
N | Y | 25°C | Group D | 2U S | S | P | Y | |
N | Y | 25°C | Group B, A | 2U P | S | P | Y | |
N | Y | 25°C | Group E3 | 2U A | S | P | Y | |
Y | N/Y | 25°C | Group B, A, D | 2U P | NA | P | Y | |
| N | N | 30°C | Group B, D | 2U S | S | P | Y |
N | N | 30°C | Group A | 2U P | S | P | Y | |
N | N | 30°C | Group E1, E2 | 2U A | S | P | Y | |
N | Y* | 30°C | Group D | 2U S | S | P | N | |
N | Y* | 30°C | Group B, A | 2U P | S | P | N | |
Y* | N | 30°C | Group B, A, D | 2U P | N/A | P | N | |
Y* | Y* | 30°C | Group B, D | 2U P | N/A | P | N | |
N | N | 25°C | Group E1 | 2U P | S | P | Y | |
N | N | 25°C | Group E3 | 2U A | S | P | Y | |
N | Y | 25°C | Group D | 2U S | S | P | N | |
N | Y | 25°C | Group B, A | 2U P | S | P | N | |
N | Y | 25°C | Group E3 | 2U A | S | P | N | |
Y | N/Y | 25°C | Group B, A, D | 2U P | NA | P | N |
- The ambient temperature is limited to 30°C when the following NVMe drives are installed in middle or rear drive bays:
Gen5 7.68 TB or larger capacity
P5336 15.36TB or larger capacity
When a part with active optical cable (AOC) is installed and the rate of the part is greater than 25 GB, the ambient temperature must be limited to 30°C or lower.
When the following parts are installed, the ambient temperature must be limited to 35°C or lower.
PCIe network interface cards (NICs) at a rate greater than or equal to 100 GB
Parts with AOC and at a rate of 25 GB
- The maximum ambient temperature is limited to 25°C when the following drives are installed:
PS1030 6.4TB or larger capacity
PS1010 7.68TB or larger capacity
Storage configurations with DWCM
This section provides thermal information for storage configurations with DWCM.
Front bays | Middle bays | Rear bays | Max. Temp. | Processor | Heat sink | Air baffle | Fan type | Support ≥ 64 GB DIMM |
---|---|---|---|---|---|---|---|---|
| N | N | 35°C | Group B, A, D, E | DWCM | S | S | Ynote 1 |
N/Y note 2 | N/Y note 2 | 35°C | Group B, A, D, E | DWCM | S | P | Y |
When standard fans are used, the max. supported ambient temperature is 30°C; when performance fans are used, the max. supported ambient temperature is 35°C.
- The ambient temperature is limited to 30°C when the following NVMe drives are installed in middle or rear drive bays:
Gen5 7.68 TB or larger capacity
Gen4 P5336 15.36T/30.72T/61.44T NVMe
- The maximum ambient temperature is limited to 25°C when the following drives are installed:
PS1030 6.4TB or larger capacity
PS1010 7.68TB or larger capacity
GPU configurations without DWCM
This section provides thermal information for GPU configurations.
For GPU configurations, group E1 processors are defined as follows: 9555(P), 9565, 9645, 9655(P), 9745, 9825, 9845, 9475F, 9575F.
Performance fans are required for servers with GPU adapters.
Half-height half-length (HHHL) single-wide (SW) GPU: A2, L4
DW GPU: A16, A30, A40, L40, L40S, A100, RTX A2000, RTX A4500, RTX A6000, RTX 4500 Ada, RTX 6000 Ada, H100, H100 NVL, AMD MI210
Front bays | Max. Temp. | Processor | Heat sink | Air baffle | Max. GPU Qty. | ||||
---|---|---|---|---|---|---|---|---|---|
SW | DW (A2000) | DW (A40/L40) | 350W DW | Other DW | |||||
| 30°C | Group B, D | 2U S | S | 8 | 3 | NA | NA | NA |
Group A | 2U P | S | 8 | 3 | NA | NA | NA | ||
Group B, A, D | 2U P | GPU | NA | NA | 3 | 3 | 3 | ||
25°C | Group E1 | 2U P | S | 6 | 3 | NA | NA | NA | |
Group E1 | 2U P | GPU | NA | NA | 2 (slot 2/5) | 2 (slot 2/5) | 2 (slot 2/5) | ||
| 30°C | Group B, D | 2U S | S | 8 | 3 | NA | NA | NA |
Group A | 2U P | S | 8 | 3 | NA | NA | NA | ||
Group B, A, D | 2U P | GPU | NA | NA | 2 (slot 2/5) | 2 (slot 2/5) | 3 | ||
25°C | Group E1 | 2U P | S | 6 | 3 | NA | NA | NA | |
Group E1 | 2U P | GPU | NA | NA | 2 (slot 2/5) | 2 (slot 2/5) | 2 (slot 2/5) | ||
| 25°C | Group B, D | 2U S | S | 6 | 3 | NA | NA | NA |
Group A | 2U P | S | 6 | 3 | NA | NA | NA | ||
Group B, A, D | 2U P | GPU | NA | NA | 2 (slot 2/5) | 2 (slot 2/5) | 2 (slot 2/5) |
GPU configurations with DWCM
This section provides thermal information for GPU configurations.
For GPU configurations, group E1 processors are defined as follows: 9555(P), 9565, 9645, 9655(P), 9745, 9825, 9845, 9475F, 9575F.
Performance fans are required for servers with GPU adapters.
Half-height half-length (HHHL) single-wide (SW) GPU: A2, L4
DW GPU: A16, A30, A40, L40, L40S, A100, RTX A2000, RTX A4500, RTX A6000, RTX 4500 Ada, RTX 6000 Ada, H100, H100 NVL, AMD MI210
Front bays | Max. Temp. | Processor | Heat sink | Air baffle | Max. GPU Qty. | ||
---|---|---|---|---|---|---|---|
SW | DW (A2000) | Other DW | |||||
| 35°C | Group B, A, D, E1 | DWCM | S | 7 | 7 | NA |
| 35°C | Group B, A, D, E1 | DWCM | GPU | NA | NA | 3note 1 |
| 35°C | Group B, A, D, E1 | DWCM | GPU | NA | NA | 3note 2 |
When three 300W or 350W GPU adapters are installed, the maximum ambient temperature is limited to 30°C in 8 x 2.5", 8 x 3.5", 16 x 2.5", FIO or FIO + 8 x 2.5" ;configuration.
In 24 x 2.5" or FIO + 16 x 2.5" configuration, the maximum ambient temperature is limited to 30°C when three 300W GPU adapters are installed; the maximum ambient temperature is limited to 25°C when three 350W GPU adapters are installed.