80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
A Voltage has dropped below its specified threshold (sensor SysBrd 12V, SysBrd 3.3V, or SysBrd 5V).
May also be shown as 800102020701ffff or 0x800102020701ffff
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Response
- (Trained service technician only) If the specified sensor is SysBrd 3.3V or SysBrd 5V, replace the system board.
- If the specified sensor is SysBrd 12V, check the IMM event log for power-supply-related issues, and resolve those issues. If the problem remains, (trained service technician only) replace the system board.
Related Links
Give documentation feedback