Skip to main content

80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

A Voltage has dropped below its specified threshold (sensor SysBrd 12V, SysBrd 3.3V, or SysBrd 5V).

May also be shown as 800102020701ffff or 0x800102020701ffff

Severity

Error

Alert Category

Critical - Voltage

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0480

SNMP Trap ID

1

Automatically Notify Support

Yes

User Response

  1. (Trained service technician only) If the specified sensor is SysBrd 3.3V or SysBrd 5V, replace the system board.
  2. If the specified sensor is SysBrd 12V, check the IMM event log for power-supply-related issues, and resolve those issues. If the problem remains, (trained service technician only) replace the system board.